The DOI matches its Crossref record; 66 of the 67 references it cites were found in a registry or an index; none of the 70 sources its claims cite is checked for support yet.
3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications
Open accessAbstract
Thermoresponsive hydrogel-based wound dressings with an incorporated antimicrobial agent can be fabricated employing 3D printing technology. A novel printable ink containing poly(N-isopropylacrylamide) (PNIPAAm) precursors, sodium alginate (ALG), methylcellulose (MC) that is laden with a mixture of octenidine dihydrochloride and 2-phenoxyethanol (Octenisept®, OCT) possess accurate printability and shape fidelity. This study also provides the protocol of ink’s use for the 3D printing of hydrogel scaffolds. The hydrogel’s physicochemical properties and drug release profiles from the hydrogel specimens to the external solution have been determined at two temperatures (20 and 37 °C). The release test showed a sustained OCT delivery into ultrapure water and the PBS solution. The temperature-responsive hydrogel exhibited antimicrobial activity against Staphylococcus aureus, Candida albicans, and Pseudomonas aeruginosa and demonstrated non-cytotoxicity towards fibroblasts. The thermoresponsive behavior along with biocompatibility, antimicrobial activity, and controlled drug release make this hydrogel a promising class of materials for wound dressing applications.
Overview
CoChat Summary
TL;DR
The authors developed a 3D-printable thermoresponsive PNIPAAm/alginate/methylcellulose hydrogel loaded with Octenisept® (octenidine dihydrochloride plus 2-phenoxyethanol) for wound dressings. The hydrogel showed shear-thinning printability, temperature-dependent swelling and OCT release, antimicrobial activity against *S. aureus*, *P. aeruginosa*, and *C. albicans*, and >98% fibroblast viability in vitro.
Key findings
- The ink was shear-thinning: G′ > G″ in the tested frequency range, critical strain ~46%, and viscosity dropped from about 175,000 Pa·s at low shear (<1 s⁻¹) to about 20 Pa·s above 1 s⁻¹. Printed tubular constructs increased by 10.7% of their original height and original diameter.
- The hydrogel had a compressive strength of 61 ± 9 kPa and an elastic modulus of 0.29 ± 0.06 MPa, and could be compressed to 20% strain without fracture.
- Swelling was temperature-dependent: in water at 20 °C the hydrogel reached 577 ± 12% after 48 h versus 228 ± 7% at 37 °C; in PBS, equilibrium swelling was 930 ± 42% at 20 °C and 556 ± 14% at 37 °C. OCT cumulative release in water reached 91.3 ± 11.7% at 37 °C and 77.2 ± 2.3% at 20 °C; in PBS at 37 °C, ~100% was released within 5 h, whereas at 20 °C 99.2 ± 7.8% was released within 24 h.
- Antimicrobial inhibition zones were 20.7 ± 0.5 mm for *P. aeruginosa*, 30.0 ± 2.5 mm for *S. aureus*, and 36.3 ± 3.3 mm for *C. albicans*; hydrogel without OCT showed no intrinsic antimicrobial activity. More than 98% of L929 fibroblasts remained viable, and 46% fewer *P. aeruginosa* and 53% fewer *S. aureus* adhered to molded hydrogel than to 3D-printed hydrogel.
Methods
- The ink combined PNIPAAm precursors with sodium alginate and methylcellulose (ALG:MC mass ratio 1:1), PEGDA, and photoinitiator; specimens were UV-cured and Ca²⁺-crosslinked. Printing used a BioX pneumatic extrusion printer with a 27G (200 µm) nozzle at 150 kPa and 3–5 mm/s.
- Characterization included rheology, uniaxial compression, ATR-FTIR, SEM, swelling at 20 and 37 °C in water and PBS, and OCT release measured by UV-Vis absorbance at 269 nm.
- Biological testing used inhibition-zone assays against *S. aureus* ATCC 6538, *P. aeruginosa* ATCC 15442, and *C. albicans* ATCC 10231, colonization assays, and neutral red cytotoxicity testing in L929 fibroblasts per ISO 10993; statistical significance was tested with Kruskal-Wallis ANOVA at p ≤ 0.05.
Limitations
- The paper states that further investigation is needed to explore the effect of hydrogel treatment on wound healing in vivo, and that the exact mechanism of temperature-induced deformation has not been quantitatively determined.
- The paper also notes that in water, 24 h incubation was insufficient to achieve 100% OCT delivery.
- Evident from the text: all biological evaluation is in vitro (antimicrobial, colonization, and cytotoxicity assays), with no in vivo efficacy, safety, or long-term stability/degradation data reported.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
0 Valid · 0 Not valid · 40 Not checked · 89 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The hydrogel exhibited a compressive strength of 61 ± 9 kPa and an elastic modulus of 0.29 ± 0.06 MPa (Figure 3e).”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.1. Characterization of the Ink and Hydrogel
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The critical strain (%) value was obtained from the intersection of the two linear parts of the dynamic strain sweep test plots and corresponded to a value of ~46% (Figure 2b).”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.1. Characterization of the Ink and Hydrogel
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Our study confirmed this observation as OCT was released more rapidly at 37 °C than that at 20 °C.”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.2. Temperature-Triggered Behavior of the Hydrogel
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The hydrogel demonstrated a temperature-dependent release of OCT.”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.2. Temperature-Triggered Behavior of the Hydrogel
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The swelling ratio in PBS at 37 °C reached almost the same value as the sample kept at 20 °C in water.”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.2. Temperature-Triggered Behavior of the Hydrogel
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
65 more claims
Create a free account to see all 129 claims and to verify the 70 references still open.
- It may state two separate claims as one. 40
- Probably not a substantial claim. 26
- The quote only partly states this claim. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“When immersed in water at a lower temperature, a dry hydrogel specimen began to swell until it achieved 577 ± 12% of its initial mass after 48 h of incubation. The swelling ratio at a temperature of 37 °C reached only ~50% (228 ± 7%) of the value at 20 °C during 48 h.”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.2. Temperature-Triggered Behavior of the Hydrogel
Reported 50 · recomputed 39.514731
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 3. Results > 3.2. Temperature-Triggered Behavior of the Hydrogel
“a dry hydrogel specimen began to swell until it achieved 577 ± 12% of its initial mass after 48 h of incubation.”
§ 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications > 2. Materials and Methods > 2.3. Characterization of the Ink and Hydrogel
“Swelling=(mwet−mdry)/mdry×100% where mdry [g] is a mass of dry hydrogel.”
Citations
Cites
3D bioprinting of tissues and organs
Murphy, S. V., & Atala, A. (2014) · Nature Biotechnology · doi:10.1038/nbt.2958 · Cited by 7,034
Li, S., Dong, S., Xu, W., Tu, S., Yan, L., Zhao, C., Ding, J., & Chen, X. (2018) · Advanced Science · doi:10.1002/advs.201700527 · Cited by 1,145
Ouyang, L., Yao, R., Zhao, Y., & Sun, W. (2016) · Biofabrication · doi:10.1088/1758-5090/8/3/035020 · Cited by 1,045
Nano-structured smart hydrogels with rapid response and high elasticity
Xia, L.-W., Xie, R., Ju, X.-J., Wang, W., Chen, Q., & Chu, L.-Y. (2013) · Nature Communications · doi:10.1038/ncomms3226 · Cited by 671
Bioprinted Amniotic Fluid-Derived Stem Cells Accelerate Healing of Large Skin Wounds
Skardal, A., Mack, D., Kapetanovic, E., Atala, A., Jackson, J. D., Yoo, J., & Soker, S. (2012) · Stem Cells Translational Medicine · doi:10.5966/sctm.2012-0088 · Cited by 660
Bacterial cellulose: a versatile biopolymer for wound dressing applications
Portela, R., Leal, C. R., Almeida, P. L., & Sobral, R. G. (2019) · Microbial Biotechnology · doi:10.1111/1751-7915.13392 · Cited by 604
Bioinspired mechanically active adhesive dressings to accelerate wound closure
Blacklow, S. O., Li, J., Freedman, B. R., Zeidi, M., Chen, C., & Mooney, D. J. (2019) · Science Advances · doi:10.1126/sciadv.aaw3963 · Cited by 547
Albanna, M., Binder, K. W., Murphy, S. V., Kim, J., Qasem, S. A., Zhao, W., Tan, J., El-Amin, I. B., Dice, D. D., Marco, J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-38366-w · Cited by 512
Li, M., Liang, Y., He, J., Zhang, H., & Guo, B. (2020) · Chemistry of Materials · doi:10.1021/acs.chemmater.0c02823 · Cited by 479
PNIPAM microgels for biomedical applications: from dispersed particles to 3D assemblies
Guan, Y., & Zhang, Y. (2011) · Soft Matter · doi:10.1039/c0sm01541e · Cited by 459
Cited by
Self-Healing Hydrogels: Preparation, Mechanism and Advancement in Biomedical Applications
Devi V. K., A., Shyam, R., Palaniappan, A., Jaiswal, A. K., Oh, T.-H., & Nathanael, A. J. (2021) · Polymers · doi:10.3390/polym13213782 · Cited by 240
Stimuli-Responsive Hydrogels: The Dynamic Smart Biomaterials of Tomorrow
Neumann, M., di Marco, G., Iudin, D., Viola, M., van Nostrum, C. F., van Ravensteijn, B. G. P., & Vermonden, T. (2023) · Macromolecules · doi:10.1021/acs.macromol.3c00967 · Cited by 229
An Overview of Cellulose Derivatives-Based Dressings for Wound-Healing Management
Tudoroiu, E.-E., Dinu-Pîrvu, C.-E., Albu Kaya, M. G., Popa, L., Anuța, V., Prisada, R. M., & Ghica, M. V. (2021) · Pharmaceuticals · doi:10.3390/ph14121215 · Cited by 191
Recent Advances in the Additive Manufacturing of Stimuli‐Responsive Soft Polymers
Tariq, A., Arif, Z. U., Khalid, M. Y., Hossain, M., Rasool, P. I., Umer, R., & Ramakrishna, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202301074 · Cited by 152
Smart 3D Printed Hydrogel Skin Wound Bandages: A Review
Tsegay, F., Elsherif, M., & Butt, H. (2022) · Polymers · doi:10.3390/polym14051012 · Cited by 147
Metadata
- Authors
- Nizioł, M., Paleczny, J., Junka, A., Shavandi, A., Dawiec-Liśniewska, A., & Podstawczyk, D.
- Affiliations
- Wrocław University of Science and Technology (PL)
- Wroclaw Medical University (PL)
- Université Libre de Bruxelles (BE)
- Department of Advanced Material Technology, Faculty of Chemistry, Wroclaw University of Science and Technology, M. Smoluchowskiego 25, 50-372 Wroclaw, Poland
- Corresponding author
- Podstawczyk, Daria
- Venue
- Bioengineering
- Publisher
- MDPI AG
- Published
- 2021-06-08
- Volume
- 8
- Issue
- 6
- Pages
- 79
- ISSN
- 2306-5354 (ISSN-L)
- PMC
- PMC8227034
- OpenAlex
- W3171047925
- Semantic Scholar
- d6070d115b31d3eff86581f945d5018250b1b1aa
- Cited by
- 85
- References
- 67
- Citations by year
- 2026: 13 · 2025: 17 · 2024: 18 · 2023: 18 · 2022: 14 · 2021: 5
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Bioengineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowe Centrum Nauki (2016/23/D/ST8/01267)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Health Sciences › Medicine › Surgery › Wound Healing and Treatments
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- thermosensitive hydrogel, 3D printing, wound dressings, wound healing, poly(N-isopropylacrylamide), sodium alginate, methylcellulose, octenidine dihydrochloride, 2-phenoxyethanol, controlled drug release, sustained drug release, antimicrobial activity, Staphylococcus aureus, Candida albicans, Pseudomonas aeruginosa, fibroblast cytotoxicity, biocompatibility, hydrogel inks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-15, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-15 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications. https://app.cochat.ai/papers/10.3390/bioengineering8060079
- The paper
- Nizioł, M., Paleczny, J., Junka, A., Shavandi, A., Dawiec-Liśniewska, A., & Podstawczyk, D. (2021). 3D Printing of Thermoresponsive Hydrogel Laden with an Antimicrobial Agent towards Wound Healing Applications. Bioengineering. https://doi.org/10.3390/bioengineering8060079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.