The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Review: 3-Aminopropyltriethoxysilane (APTES) Deposition Methods on Oxide Surfaces in Solution and Vapor Phases for Biosensing Applications
Open accessAbstract
Surface functionalization and bioreceptor immobilization are critical processes in developing a highly sensitive and selective biosensor. The silanization process with 3-aminopropyltriethoxysilane (APTES) on oxide surfaces is frequently used for surface functionalization because of beneficial characteristics such as its bifunctional nature and low cost. Optimizing the deposition process of the APTES layer to obtain a monolayer is crucial to having a stable surface and effectively immobilizing the bioreceptors, which leads to the improved repeatability and sensitivity of the biosensor. This review provides an overview of APTES deposition methods, categorized into the solution-phase and vapor-phase, and a comprehensive summary and guide for creating stable APTES monolayers on oxide surfaces for biosensing applications. A brief explanation of APTES is introduced, and the APTES deposition methods with their pre/post-treatments and characterization results are discussed. Lastly, APTES deposition methods on nanoparticles used for biosensors are briefly described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Metal Oxide Gas Sensors: Sensitivity and Influencing Factors
Wang, C., Yin, L., Zhang, L., Xiang, D., & Gao, R. (2010) · Sensors · doi:10.3390/s100302088 · Cited by 2,928
The surface chemistry of amorphous silica. Zhuravlev model
Zhuravlev, L. T. (2000) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(00)00556-2 · Cited by 2,474
How Strong Is a Covalent Bond?
Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E. (1999) · Science · doi:10.1126/science.283.5408.1727 · Cited by 1,095
Covalent Surface Modification of Oxide Surfaces
Pujari, S. P., Scheres, L., Marcelis, A. T. M., & Zuilhof, H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201306709 · Cited by 934
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
Optimization of Silica Silanization by 3-Aminopropyltriethoxysilane
Howarter, J. A., & Youngblood, J. P. (2006) · Langmuir · doi:10.1021/la061240g · Cited by 752
Functionalization of SBA-15 with APTES and Characterization of Functionalized Materials
Maria Chong, A. S., & Zhao, X. S. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp035877+ · Cited by 741
Fadeev, A. Y., & McCarthy, T. J. (2000) · Langmuir · doi:10.1021/la000471z · Cited by 626
Metadata
- Authors
- Sypabekova, M., Hagemann, A., Rho, D., & Kim, S.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2022-12-27
- Volume
- 13
- Issue
- 1
- Pages
- 36
- ISSN
- 2079-6374 (ISSN-L)
- OpenAlex
- W4313225293
- Cited by
- 304
- References
- 53
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review: 3-Aminopropyltriethoxysilane (APTES) Deposition Methods on Oxide Surfaces in Solution and Vapor Phases for Biosensing Applications. https://app.cochat.ai/papers/10.3390/bios13010036
- The paper
- Sypabekova, M., Hagemann, A., Rho, D., & Kim, S. (2022). Review: 3-Aminopropyltriethoxysilane (APTES) Deposition Methods on Oxide Surfaces in Solution and Vapor Phases for Biosensing Applications. Biosensors. https://doi.org/10.3390/bios13010036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.