The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring
Open accessAbstract
The modern healthcare system strives to provide patients with more comfortable and less invasive experiences, focusing on noninvasive and painless diagnostic and treatment methods. A key priority is the early diagnosis of life-threatening diseases, which can significantly improve patient outcomes by enabling treatment at earlier stages. While most patients must undergo diagnostic procedures before beginning treatment, many existing methods are invasive, time-consuming, and inconvenient. To address these challenges, electrochemical-based wearable and point-of-care (PoC) sensing devices have emerged, playing a crucial role in the noninvasive, continuous, periodic, and remote monitoring of key biomarkers. Due to their numerous advantages, several wearable and PoC devices have been developed. In this focused review, we explore the advancements in metal–organic frameworks (MOFs)-based wearable and PoC devices. MOFs are porous crystalline materials that are cost-effective, biocompatible, and can be synthesized sustainably on a large scale, making them promising candidates for sensor development. However, research on MOF-based wearable and PoC sensors remains limited, and no comprehensive review has yet to synthesize the existing knowledge in this area. This review aims to fill that gap by emphasizing the design of materials, fabrication methodologies, sensing mechanisms, device construction, and real-world applicability of these sensors. Additionally, we underscore the importance and potential of MOF-based wearable and PoC sensors for advancing healthcare technologies. In conclusion, this review sheds light on the current state of the art, the challenges faced, and the opportunities ahead in MOF-based wearable and PoC sensing technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 4 (A) Stepwise fabrication of CNT/MWCNT/PDMS and (B) fabrication of glucose sensor. (C) Current response obtained using the developed sensor for the detection of glucose in volunteers’ sweat. Reproduced with permission from [66]. (D) Graphical representation of the fabricated headband. (E) Non-enzymatic glucose sensing using the headband. (F) Actual photograph of headband integrated with glucose sensor. (G) Photograph of a volunteer wearing the headband and perspiration analysis using a smartphone. (H) Glucose concentration measured in the perspiration and blood of a human for 10 days. Reproduced with permission from [68].](/paper-figures/30181d90dc22416d8f48c31bd330c57a/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-4.jpg)

![Figure 2 (A) Scheme for the synthesis of bimetallic MOF and streptavidin-conjugated MOF. (B) Fabrication of flexible and wearable patch sensors. (C) Scheme for the fabrication of a cortisol sensor. (D) Redox peak current changes in the sensor in the presence of hydroquinone and hydrogen peroxide for 10 cycles. (E) Cortisol detection in sweat samples (inset: photograph of a volunteer wearing the patch sensor). Reproduced with permission from [55].](/paper-figures/8f4ff2179c0849df824c8c6b798d8962/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-2.jpg)
![Figure 3 (A) Graphical representation for the hydrothermal synthesis of CoFe-MOF-CoFe2O4 nanohybrids. (B) Stepwise fabrication of the SARS-CoV-2 sensor and its electrochemical response. Reproduced with permission from [56].](/paper-figures/77330f68a9244b16a531d59c6b998966/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-3.jpg)
![Figure 5 (A) Graphical representation for the stepwise synthesis of GOx/Hemin@NC-ZIF. (B–E) TEM images at different etching times. (F) HAADF and its EDS line scan. (G) EDS mappings for various elements. (H) Relative activities of different electrocatalysts. (I) Photograph of wearable sweatband and its catalytic mechanism toward glucose oxidation along with perspiration analysis on a smartphone display. (J) Relative activities of different electrocatalysts in various reaction conditions. (K) Glucose concentration obtained through perspiration and blood of a human within 14 days. Reproduced with permission from [70].](/paper-figures/047db3fefc164a5586748a5bec9726c9/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-5.jpg)
![Figure 6 Graphical representation of (A) stepwise synthesis of hybridized nanoporous carbon, (B) construction of glucose, lactate, temperature, and pH sensors, and (C–G) stepwise fabrication of the wearable patch sensor and photograph of a volunteer wearing the patch sensor during exercise. Reproduced with permission from [71].](/paper-figures/fda34b99c7fe459684715c786a81ef85/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-6.jpg)
![Figure 7 (A) Photograph of wearable LD sensor and its electrochemical sensing of LD. (B) Graphical representation of various components of the three-electrode system. (C) Block diagram of the potentiostat. (D–F) Real-time application of the fabricated LD sensor. Reproduced with permission from [77].](/paper-figures/e9268f91e19b4dceaabde7717abd9bb7/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-7.jpg)
![Figure 8 (A) Graphical representation for the synthesis of (A) zinc–glutamate MOF, (B) MXene, and (C) MOF-MXene nanocomposite. (D) Electrochemical sensing of melatonin and its amperometric response. (E) Scheme for the fabrication of band-aid based prototype melatonin sensor. (F) Photograph of prototype sensor connected to the portable potentiostat. (G) Various real samples analyzed. Reproduced with permission from [80].](/paper-figures/3c88776a10fc4b88a617c226f2c55d27/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-8.jpg)
![Figure 9 (A) Schematic illustration of various components of the sensor and CEES sensing mechanism. (B) Wearable and PoC sensor and potentiometric responses obtained for drinking water and aerosols. (C,D) Potentiometric response obtained for textile-based wearable sensor for various concentrations of Cl ions and CEES. Reproduced with permission from [83].](/paper-figures/dd838de260634bc08533fcd1afa6e00e/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-9.jpg)
![Figure 10 (A) Scheme for the synthesis of MOF@CNTF and (B) electrochemical cell. (C) Photograph of a volunteer wearing the band-based wearable sensor and its components. (D) Potential response and (E) real-time sweat sodium concentrations of two subjects obtained using the wearable sensor. Reproduced with permission from [85].](/paper-figures/1574d54b76ff4de09bf1880d635981d9/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-10.jpg)
![Figure 11 (A) Scheme for the synthesis of UC@MAF7. (B) Top view and cross-sectional view of the fabricated sensor. (C) UA sensing mechanism. (D) Schematic illustration of sensor fabrication and sensing mechanism. (E) Schematic representation of top and cross-sectional view of the microfluidic channel and actual photographs of fluids flowing in the microfluidic channel at different time intervals. (F) Photograph of printed circuit board consisting of (1) microcontroller, (2) analog front end, and (3) Bluetooth transceiver along with block diagram of the PCB. (G) Photographs of the subjects wearing the sensor on different parts of the body and UA concentrations measured in 10 volunteers. Reproduced with permission from [86].](/paper-figures/6a0ff81287ee40c5ab59fa88f9c8b981/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-11.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Chemistry and Applications of Metal-Organic Frameworks
Furukawa, H., Cordova, K. E., O’Keeffe, M., & Yaghi, O. M. (2013) · Science · doi:10.1126/science.1230444 · Cited by 16,945
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Metal–organic frameworks: Structures and functional applications
Jiao, L., Seow, J. Y. R., Skinner, W. S., Wang, Z. U., & Jiang, H.-L. (2019) · Materials Today · doi:10.1016/j.mattod.2018.10.038 · Cited by 1,404
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Metal–organic frameworks for energy storage: Batteries and supercapacitors
Wang, L., Han, Y., Feng, X., Zhou, J., Qi, P., & Wang, B. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.09.002 · Cited by 1,298
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Cited by
Thanjavur, N., Laxmi, B., & Kim, Y. (2025) · Biosensors · doi:10.3390/bios15010038 · Cited by 63
Self-citationDeffo, G., Tamo, A. K., Fotsop, C. G., Tchoumi, H. H. B., Talla, D. E. N., Wabo, C. G., Ngaha, M. C. D., Temgoua, R. C. T., Doungmo, G., Njanja, E., et al. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.216680 · Cited by 63
Isa, A., Gharibi, M., Çetinkaya, A., & Özkan, S. A. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113210 · Cited by 45
Wearable MOF biosensors: A new frontier in real-time health monitoring
Rabiee, N. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118156 · Cited by 42
Biochips on the Move: Emerging Trends in Wearable and Implantable Lab-on-Chip Health Monitors
Kazanskiy, N. L., Khorin, P. A., & Khonina, S. N. (2025) · Electronics · doi:10.3390/electronics14163224 · Cited by 30
Metadata
- Authors
- Theyagarajan, K., & Kim, Y.-J.
- Affiliations
- Gachon University (KR)
- Corresponding author
- Kim, Young-Joon
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2024-10-10
- Volume
- 14
- Issue
- 10
- Pages
- 492
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC11506055
- OpenAlex
- W4403304127
- Cited by
- 31
- References
- 86
- Citations by year
- 2026: 16 · 2025: 14 · 2024: 1
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Research Foundation of Korea (NRF-2022R1F1A1074346, RS-2024-00433166)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Inorganic Chemistry › Metal-Organic Frameworks: Synthesis and Applications
- Keywords
- metal-organic frameworks, wearable sensors, point-of-care testing, electrochemical sensor, remote patient monitoring, early diagnosis, sensor fabrication, sensing mechanism
- MeSH terms
- Metal-Organic Frameworks, Wearable Electronic Devices, Humans, Monitoring, Physiologic, Biosensing Techniques, Point-of-Care Systems, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring. https://app.cochat.ai/papers/10.3390/bios14100492
- The paper
- Theyagarajan, K., & Kim, Y.-J. (2024). Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring. Biosensors. https://doi.org/10.3390/bios14100492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.