The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring
Open accessAbstract
The modern healthcare system strives to provide patients with more comfortable and less invasive experiences, focusing on noninvasive and painless diagnostic and treatment methods. A key priority is the early diagnosis of life-threatening diseases, which can significantly improve patient outcomes by enabling treatment at earlier stages. While most patients must undergo diagnostic procedures before beginning treatment, many existing methods are invasive, time-consuming, and inconvenient. To address these challenges, electrochemical-based wearable and point-of-care (PoC) sensing devices have emerged, playing a crucial role in the noninvasive, continuous, periodic, and remote monitoring of key biomarkers. Due to their numerous advantages, several wearable and PoC devices have been developed. In this focused review, we explore the advancements in metal–organic frameworks (MOFs)-based wearable and PoC devices. MOFs are porous crystalline materials that are cost-effective, biocompatible, and can be synthesized sustainably on a large scale, making them promising candidates for sensor development. However, research on MOF-based wearable and PoC sensors remains limited, and no comprehensive review has yet to synthesize the existing knowledge in this area. This review aims to fill that gap by emphasizing the design of materials, fabrication methodologies, sensing mechanisms, device construction, and real-world applicability of these sensors. Additionally, we underscore the importance and potential of MOF-based wearable and PoC sensors for advancing healthcare technologies. In conclusion, this review sheds light on the current state of the art, the challenges faced, and the opportunities ahead in MOF-based wearable and PoC sensing technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 4 (A) Stepwise fabrication of CNT/MWCNT/PDMS and (B) fabrication of glucose sensor. (C) Current response obtained using the developed sensor for the detection of glucose in volunteers’ sweat. Reproduced with permission from [66]. (D) Graphical representation of the fabricated headband. (E) Non-enzymatic glucose sensing using the headband. (F) Actual photograph of headband integrated with glucose sensor. (G) Photograph of a volunteer wearing the headband and perspiration analysis using a smartphone. (H) Glucose concentration measured in the perspiration and blood of a human for 10 days. Reproduced with permission from [68].](/paper-figures/30181d90dc22416d8f48c31bd330c57a/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-4.jpg)

![Figure 2 (A) Scheme for the synthesis of bimetallic MOF and streptavidin-conjugated MOF. (B) Fabrication of flexible and wearable patch sensors. (C) Scheme for the fabrication of a cortisol sensor. (D) Redox peak current changes in the sensor in the presence of hydroquinone and hydrogen peroxide for 10 cycles. (E) Cortisol detection in sweat samples (inset: photograph of a volunteer wearing the patch sensor). Reproduced with permission from [55].](/paper-figures/8f4ff2179c0849df824c8c6b798d8962/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-2.jpg)
![Figure 3 (A) Graphical representation for the hydrothermal synthesis of CoFe-MOF-CoFe2O4 nanohybrids. (B) Stepwise fabrication of the SARS-CoV-2 sensor and its electrochemical response. Reproduced with permission from [56].](/paper-figures/77330f68a9244b16a531d59c6b998966/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-3.jpg)
![Figure 5 (A) Graphical representation for the stepwise synthesis of GOx/Hemin@NC-ZIF. (B–E) TEM images at different etching times. (F) HAADF and its EDS line scan. (G) EDS mappings for various elements. (H) Relative activities of different electrocatalysts. (I) Photograph of wearable sweatband and its catalytic mechanism toward glucose oxidation along with perspiration analysis on a smartphone display. (J) Relative activities of different electrocatalysts in various reaction conditions. (K) Glucose concentration obtained through perspiration and blood of a human within 14 days. Reproduced with permission from [70].](/paper-figures/047db3fefc164a5586748a5bec9726c9/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-5.jpg)
![Figure 6 Graphical representation of (A) stepwise synthesis of hybridized nanoporous carbon, (B) construction of glucose, lactate, temperature, and pH sensors, and (C–G) stepwise fabrication of the wearable patch sensor and photograph of a volunteer wearing the patch sensor during exercise. Reproduced with permission from [71].](/paper-figures/fda34b99c7fe459684715c786a81ef85/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-6.jpg)
![Figure 7 (A) Photograph of wearable LD sensor and its electrochemical sensing of LD. (B) Graphical representation of various components of the three-electrode system. (C) Block diagram of the potentiostat. (D–F) Real-time application of the fabricated LD sensor. Reproduced with permission from [77].](/paper-figures/e9268f91e19b4dceaabde7717abd9bb7/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-7.jpg)
![Figure 8 (A) Graphical representation for the synthesis of (A) zinc–glutamate MOF, (B) MXene, and (C) MOF-MXene nanocomposite. (D) Electrochemical sensing of melatonin and its amperometric response. (E) Scheme for the fabrication of band-aid based prototype melatonin sensor. (F) Photograph of prototype sensor connected to the portable potentiostat. (G) Various real samples analyzed. Reproduced with permission from [80].](/paper-figures/3c88776a10fc4b88a617c226f2c55d27/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-8.jpg)
![Figure 9 (A) Schematic illustration of various components of the sensor and CEES sensing mechanism. (B) Wearable and PoC sensor and potentiometric responses obtained for drinking water and aerosols. (C,D) Potentiometric response obtained for textile-based wearable sensor for various concentrations of Cl ions and CEES. Reproduced with permission from [83].](/paper-figures/dd838de260634bc08533fcd1afa6e00e/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-9.jpg)
![Figure 10 (A) Scheme for the synthesis of MOF@CNTF and (B) electrochemical cell. (C) Photograph of a volunteer wearing the band-based wearable sensor and its components. (D) Potential response and (E) real-time sweat sodium concentrations of two subjects obtained using the wearable sensor. Reproduced with permission from [85].](/paper-figures/1574d54b76ff4de09bf1880d635981d9/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-10.jpg)
![Figure 11 (A) Scheme for the synthesis of UC@MAF7. (B) Top view and cross-sectional view of the fabricated sensor. (C) UA sensing mechanism. (D) Schematic illustration of sensor fabrication and sensing mechanism. (E) Schematic representation of top and cross-sectional view of the microfluidic channel and actual photographs of fluids flowing in the microfluidic channel at different time intervals. (F) Photograph of printed circuit board consisting of (1) microcontroller, (2) analog front end, and (3) Bluetooth transceiver along with block diagram of the PCB. (G) Photographs of the subjects wearing the sensor on different parts of the body and UA concentrations measured in 10 volunteers. Reproduced with permission from [86].](/paper-figures/6a0ff81287ee40c5ab59fa88f9c8b981/metal-organic-frameworks-based-wearable-and-point-of-care-electrochemical-figure-11.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Chemistry and Applications of Metal-Organic Frameworks
Furukawa, H., Cordova, K. E., O’Keeffe, M., & Yaghi, O. M. (2013) · Science · doi:10.1126/science.1230444 · Cited by 16,945
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Metal–organic frameworks: Structures and functional applications
Jiao, L., Seow, J. Y. R., Skinner, W. S., Wang, Z. U., & Jiang, H.-L. (2019) · Materials Today · doi:10.1016/j.mattod.2018.10.038 · Cited by 1,404
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Metal–organic frameworks for energy storage: Batteries and supercapacitors
Wang, L., Han, Y., Feng, X., Zhou, J., Qi, P., & Wang, B. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.09.002 · Cited by 1,298
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2013) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 696
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Metal–Organic Framework-Based Sensors for Environmental Contaminant Sensing
Fang, X., Zong, B., & Mao, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0218-0 · Cited by 576
Metal-organic frameworks for direct electrochemical applications
Xu, Y., Li, Q., Xue, H., & Pang, H. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.08.010 · Cited by 557
Metal–organic frameworks meet scalable and sustainable synthesis
Julien, P. A., Mottillo, C., & Friščić, T. (2017) · Green Chemistry · doi:10.1039/c7gc01078h · Cited by 520
Metal-organic framework-based materials as an emerging platform for advanced electrochemical sensing
Liu, C.-S., Li, J., & Pang, H. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213222 · Cited by 484
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
The Applications of Metal−Organic Frameworks in Electrochemical Sensors
Liu, L., Zhou, Y., Liu, S., & Xu, M. (2018) · ChemElectroChem · doi:10.1002/celc.201700931 · Cited by 409
Metal–organic framework composites and their electrochemical applications
Xue, Y., Zheng, S., Xue, H., & Pang, H. (2019) · Journal of Materials Chemistry A · doi:10.1039/c8ta12178h · Cited by 389
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Metal–organic framework composites as electrocatalysts for electrochemical sensing applications
Kempahanumakkagari, S., Vellingiri, K., Deep, A., Kwon, E. E., Bolan, N., & Kim, K.-H. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.028 · Cited by 370
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Metal oxide based non-enzymatic electrochemical sensors for glucose detection
Dong, Q., Ryu, H., & Lei, Y. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.137744 · Cited by 338
Design and sensing applications of metal–organic framework composites
Lei, J., Qian, R., Ling, P., Cui, L., & Ju, H. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.02.012 · Cited by 332
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Daniel, M., Mathew, G., Anpo, M., & Neppolian, B. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214627 · Cited by 294
Paper based diagnostics for personalized health care: Emerging technologies and commercial aspects
Mahato, K., Srivastava, A., & Chandra, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.001 · Cited by 280
Metal-organic frameworks: A novel platform for combined advanced therapies
Rojas, S., Arenas-Vivo, A., & Horcajada, P. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.02.032 · Cited by 261
Metal–organic frameworks for electrochemical applications
Liu, W., & Yin, X.-B. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.07.011 · Cited by 260
Joshi, A., & Kim, K.-H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112046 · Cited by 247
Recent trends and perspectives in electrochemical sensors based on MOF-derived materials
Gonçalves, J. M., Martins, P. R., Rocha, D. P., Matias, T. A., Julião, M. S. S., Munoz, R. A. A., & Angnes, L. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc02025k · Cited by 225
Shu, Y., Su, T., Lu, Q., Shang, Z., Xu, Q., & Hu, X. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04106 · Cited by 221
Metal−Organic Frameworks toward Electrochemical Sensors: Challenges and Opportunities
Chuang, C., & Kung, C. (2020) · Electroanalysis · doi:10.1002/elan.202060111 · Cited by 184
Electrochemical sensors: From the bench to the skin
Mahato, K., & Wang, J. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.130178 · Cited by 180
3D printing of polymer composites to fabricate wearable sensors: A comprehensive review
Osman, A., & Lü, J. (2023) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2023.100734 · Cited by 151
Rasheed, T., & Rızwan, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113867 · Cited by 131
Xiao, J., Fan, C. G., Xu, T., Su, L., & Zhang, X. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131586 · Cited by 115
Asaduzzaman, M., Zahed, M. A., Sharifuzzaman, M., Reza, M. S., Hui, X., Sharma, S., Shin, Y. D., & Park, J. Y. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114846 · Cited by 106
Zhu, X., Yuan, S., Ju, Y., Yang, J. H., Zhao, C., & Liu, H. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02328 · Cited by 105
3D biosensors in advanced medical diagnostics of high mortality diseases
Rebelo, R., Barbosa, A. I., Caballero, D., Kwon, I. K., Oliveira, J. M., Kundu, S. C., Reis, R. L., & Correlo, V. M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.12.057 · Cited by 101
Progress and opportunities for metal–organic framework composites in electrochemical sensors
Zhang, W., Li, X., Ding, X., Hua, K., Sun, A., Hu, X., Nie, Z., Zhang, Y., Wang, J., Li, R., et al. (2023) · RSC Advances · doi:10.1039/d3ra00966a · Cited by 99
Pashazadeh‐Panahi, P., Belali, S., Sohrabi, H., Oroojalian, F., Hashemzaei, M., Mokhtarzadeh, A., & de la Guárdia, M. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116285 · Cited by 98
Wijesundara, Y. H., Howlett, T. S., Kumari, S., & Gassensmith, J. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00409 · Cited by 96
Hydrophilic metal-organic frameworks integrated uricase for wearable detection of sweat uric acid
Xiao, J., Luo, Y., Su, L., Lu, J., Han, W., Xu, T., & Zhang, X. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339843 · Cited by 93
Advancements in wearable sensors for cardiovascular disease detection for health monitoring
Khan, B., Riaz, Z., Ahmad, R. U. S., & Khoo, B. L. (2024) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2024.100804 · Cited by 89
Chen, X., Feng, X., Zhan, T., Xue, Y., Li, H., Han, G.-C., Chen, Z., & Kraatz, H. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134498 · Cited by 85
Recent advances in wearable electrochemical biosensors towards technological and material aspects
Fakhr, M. H., Carrasco, I. L., Belyaev, D., Kang, J.-H., Shin, Y., Yeo, J., Koh, W., Ham, J., Michaelis, A., Opitz, J. L., et al. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100503 · Cited by 84
Jiang, X., Wang, H., Chai, Y., Shi, W., & Yuan, R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01075 · Cited by 82
Theyagarajan, K., & Kim, Y. (2023) · Biosensors · doi:10.3390/bios13040424 · Cited by 81
Self-citationMohanapriya, D., Satija, J., Senthilkumar, S., Ponnusamy, V. K., & Thenmozhi, K. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.215746 · Cited by 81
Bagchi, D., Bhattacharya, A., Dutta, T., Nag, S., Wulferding, D., Lemmens, P., & Pal, S. K. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b00223 · Cited by 77
Wang, Q., Chen, M., Xiong, C., Zhu, X., Chen, C., Zhou, F., Dong, Y., Wang, Y., Xu, J., Li, Y., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113695 · Cited by 77
Involvement of metal organic frameworks in wearable electrochemical sensor for efficient performance
Sharma, A., Singh, A., Gupta, V., Sundramoorthy, A. K., & Arya, S. K. (2023) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2023.e00200 · Cited by 76
Green MIP-202(Zr) Catalyst: Degradation and Thermally Robust Biomimetic Sensing of Nerve Agents
Sandhu, S. S., Goud, K. Y., Fernando, P. U. A. I., Kalaj, M., Tostado, N., Teymourian, H., Alberts, E. M., Thornell, T. L., Jenness, G. R., Harvey, S. P., et al. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c08356 · Cited by 74
Su, T., Mi, Z., Xia, Y., Jin, D., Xu, Q. H., Hu, X., & Shu, Y. (2023) · Talanta · doi:10.1016/j.talanta.2023.124620 · Cited by 67
Ren, X. Z., Zhang, D., Li, C., Zhao, J., Feng, R., Zhang, Y., Xu, R. L., & Wei, Q. L. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c05556 · Cited by 60
Xia, Y., Su, T., Mi, Z., Feng, Z., Hong, Y., Hu, X., & Shu, Y. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341754 · Cited by 58
Elashery, S. E. A., Attia, N. F., & Oh, H. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339518 · Cited by 55
Yin, H., He, H., Li, T., Hu, M., Huang, W., Wang, Z., Yang, X., Yao, W., Xiao, F., Wu, Y., et al. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340730 · Cited by 55
Wang, Z., Liu, T., Yu, Y., Asif, M., Xu, N., Xiao, F., & Liu, H. (2018) · Small · doi:10.1002/smll.201802670 · Cited by 54
Recent Progress in MOF-Based Electrochemical Sensors for Non-Enzymatic Glucose Detection
Li, Z., Zeng, W., & Li, Y. (2023) · Molecules · doi:10.3390/molecules28134891 · Cited by 54
Zheng, X. T., Leoi, M. W. N., Yu, Y., Tan, S. C. L., Nadzri, N., Goh, W. P., Jiang, C., Ni, X., Wang, P., Zhao, M., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202310121 · Cited by 51
Kalasin, S., Sangnuang, P., & Surareungchai, W. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02085 · Cited by 48
Wang, S., Liu, M., Shi, Y., Yang, X., Li, L., Lu, Q., Zheng, H., Feng, S., Bai, Y., & Zhang, T. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132290 · Cited by 48
Rebecca, P. N. B., Durgalakshmi, D., Balakumar, S., & Rakkesh, R. A. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149789 · Cited by 41
Integration of devices based on metal–organic frameworks: A promising platform for chemical sensing
Wang, X., Ma, T., Ma, J.-G., & Cheng, P. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.216067 · Cited by 40
Asaduzzaman, M., Hui, X., Reza, M. S., Pradhan, G. B., Jeong, S. H., Song, H., Zahed, M. A., Sharifuzzaman, M., & Park, J. Y. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.145836 · Cited by 38
A review on the recent advancements in nanomaterials for nonenzymatic lactate sensing
Jannath, K. A., Karim, M. M., Saputra, H. A., Seo, K., Kim, K. B., & Shim, Y. (2023) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.12678 · Cited by 32
Li, C., Xu, R. L., Liu, X., Tian, L., Wang, H., Zhang, Y., & Wei, Q. L. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.135383 · Cited by 30
Advancements in Brain Research: The In Vivo/In Vitro Electrochemical Detection of Neurochemicals
Xu, X., Zuo, Y., Chen, S., Hatami, A., & Gu, H. C. (2024) · Biosensors · doi:10.3390/bios14030125 · Cited by 26
Richard, B., Niyas, K., Ankitha, M., & Rasheed, P. A. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.4c01062 · Cited by 26
Chang, L., Rinawati, M., Guo, Y., Lin, Y.-C., Chang, C.-Y., Su, W.-N. J., Mizuguchi, H., Huang, W., Chen, J., & Yeh, M. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.4c01899 · Cited by 26
Wang, L., Zhou, Z., Niu, J., Peng, J., Wang, T., & Hou, X. (2024) · Talanta · doi:10.1016/j.talanta.2024.126412 · Cited by 26
Theyagarajan, K., Sruthi, V. P., Satija, J., Senthilkumar, S., & Kim, Y. (2024) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2024.100840 · Cited by 26
Self-citationDisley, J., Gil‐Ramírez, G., & González-Rodríguez, J. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117282 · Cited by 24
Banga, I. K., Paul, A., Sardesai, A. U., Muthukumar, S., & Prasad, S. (2021) · RSC Advances · doi:10.1039/d1ra03093k · Cited by 24
Zha, X., Yang, W., Shi, L., Zeng, Q., Xu, J., & Yang, Y. (2023) · Dalton Transactions · doi:10.1039/d2dt03311a · Cited by 23
Palanisamy, S., Lee, L., Kao, C.-F., Chen, W., Wang, H.-C., Shen, S.-T., Jian, J.-W., Yuan, S. F., Kung, Y.-A., & Wang, Y. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133960 · Cited by 23
Advancing healthcare applications: wearable sensors utilizing metal–organic frameworks
Rebecca, P. N. B., Durgalakshmi, D., Balakumar, S., & Rakkesh, R. A. (2023) · Sensors & Diagnostics · doi:10.1039/d3sd00214d · Cited by 19
Theyagarajan, K., Lakshmi, B. A., & Kim, Y. (2024) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2024.114209 · Cited by 18
Self-citationSandhu, S. S., Chang, A., Fernando, P. U. A. I., Morales, J. F., Tostado, N., Jernberg, J., Moores, L. C., & Wang, J. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132818 · Cited by 15
AuNP@ZeNose (ZIF-based electrochemical nose) for detection of flu biomarker in breath
Banga, I. K., Paul, A., Sardesai, A. U., Muthukumar, S., & Prasad, S. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05334-1 · Cited by 14
A nanohybrid-based smartphone-compatible high performance electrochemical glucose sensor
Theyagarajan, K., Lakshmi, B. A., Kim, C., & Kim, Y. (2024) · Materials Today Chemistry · doi:10.1016/j.mtchem.2024.102282 · Cited by 13
Self-citationNon‐enzyme electrochemical sensing fabrics and wearable applications based on bimetallic NiCo‐MOFs
Yuan, M., Wang, L., Li, K., Zhang, Q., Li, Y., Hou, C., & Wang, H. (2023) · Electroanalysis · doi:10.1002/elan.202200556 · Cited by 12
Cited by
Thanjavur, N., Laxmi, B., & Kim, Y. (2025) · Biosensors · doi:10.3390/bios15010038 · Cited by 63
Self-citationDeffo, G., Tamo, A. K., Fotsop, C. G., Tchoumi, H. H. B., Talla, D. E. N., Wabo, C. G., Ngaha, M. C. D., Temgoua, R. C. T., Doungmo, G., Njanja, E., et al. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.216680 · Cited by 63
Isa, A., Gharibi, M., Çetinkaya, A., & Özkan, S. A. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113210 · Cited by 45
Wearable MOF biosensors: A new frontier in real-time health monitoring
Rabiee, N. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118156 · Cited by 42
Biochips on the Move: Emerging Trends in Wearable and Implantable Lab-on-Chip Health Monitors
Kazanskiy, N. L., Khorin, P. A., & Khonina, S. N. (2025) · Electronics · doi:10.3390/electronics14163224 · Cited by 30
Metadata
- Authors
- Theyagarajan, K., & Kim, Y.-J.
- Affiliations
- Gachon University (KR)
- Corresponding author
- Kim, Young-Joon
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2024-10-10
- Volume
- 14
- Issue
- 10
- Pages
- 492
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC11506055
- OpenAlex
- W4403304127
- Cited by
- 31
- References
- 86
- Citations by year
- 2026: 16 · 2025: 14 · 2024: 1
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Research Foundation of Korea (NRF-2022R1F1A1074346, RS-2024-00433166)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Inorganic Chemistry › Metal-Organic Frameworks: Synthesis and Applications
- Keywords
- metal-organic frameworks, wearable sensors, point-of-care testing, electrochemical sensor, remote patient monitoring, early diagnosis, sensor fabrication, sensing mechanism
- MeSH terms
- Metal-Organic Frameworks, Wearable Electronic Devices, Humans, Monitoring, Physiologic, Biosensing Techniques, Point-of-Care Systems, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.