The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review
Open accessAbstract
Thermal comfort and indoor air quality (IAQ) of educational buildings can affect students’ academic performance and well-being and are closely related to ventilation energy consumption. Demands of the indoor environmental quality within the classroom generally vary with the education levels and result in ventilation energy consumption accounting for a considerable proportion of the total energy use in bulk educational buildings. Its huge energy-saving potential is attracting worldwide attention from scholars and governments. Therefore, appropriate operation strategies of ventilation systems should be adopted to effectively reduce energy consumption without sacrificing thermal comfort and IAQ. However, the absence of relevant standards and guidelines for designing a quality classroom environment considering the special features of educational buildings remains an important research question. This study conducts a comprehensive review to determine research gaps and identify future directions for the interaction between thermal comfort, IAQ and ventilation energy consumption for educational buildings. The review results show that: (1) The thermal comfort prediction model should consider the influences of genders, ages and socioeconomic backgrounds; (2) The mixed-mode ventilation coupling the natural and mechanical approaches is preferred given its advantage of lower energy consumption and improved thermal comfort, but its control strategies need further exploration; (3) Optimizing passive design parameters of buildings (e.g., window to wall ratios, window orientations and sun shading installations) can significantly reduce the ventilation demands while maintaining indoor thermal comfort; (4) More studies are required for investigating thermal comfort in educational buildings during the heating period; and (5) IAQ of university buildings clearly requires further studies, especially on bacterial and fungal aerosol pollutants, for a more comprehensive assessment of the built environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Adaptive Thermal Comfort: Principles and Practice
Nicol, F., Humphreys, M., & Roaf, S. (2012) · doi:10.4324/9780203123010 · Cited by 636
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Personal factors in thermal comfort assessment: clothing properties and metabolic heat production
Havenith, G., Holmér, I., & Parsons, K. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00008-7 · Cited by 376
Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., & Rüden, H. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.053 · Cited by 359
Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain
Rivas, I., Viana, M., Moreno, T., Pandolfi, M., Amato, F., Reche, C., Bouso, L., Àlvarez-Pedrerol, M., Alastuey, A., Sunyer, J., et al. (2014) · Environment International · doi:10.1016/j.envint.2014.04.009 · Cited by 345 · cited 1×
“The significant parameters related to the educational environments include the microclimatic parameters (i.e., temperature, relative humidity, and ventilation rate) [31,32], building age [24], occupancy level [33], and floor covering [34] etc.”
BackgroundIndoor air quality investigation according to age of the school buildings in Korea
Yang, W., Sohn, J., Kim, J., Son, B., & Park, J. (2009) · Journal of Environmental Management · doi:10.1016/j.jenvman.2007.10.003 · Cited by 235
Cited by
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Metadata
- Authors
- Jia, L.-R., Han, J., Chen, X., Li, Q.-Y., Lee, C.-C., & Fung, Y.-H.
- Venue
- Buildings
- Publisher
- MDPI AG
- Published
- 2021-11-28
- Volume
- 11
- Issue
- 12
- Pages
- 591
- ISSN
- 2075-5309 (ISSN-L)
- OpenAlex
- W3215685902
- Cited by
- 212
- References
- 7
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review. https://app.cochat.ai/papers/10.3390/buildings11120591
- The paper
- Jia, L.-R., Han, J., Chen, X., Li, Q.-Y., Lee, C.-C., & Fung, Y.-H. (2021). Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review. Buildings. https://doi.org/10.3390/buildings11120591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.