Testing Lab-on-a-Chip Technology for Culturing Human Melanoma Cells under Simulated Microgravity
Open accessThe DOI matches its Crossref record; 75 of the 77 references it cites were found in a registry or an index.
Abstract
The dynamic development of the space industry makes space flights more accessible and opens up new opportunities for biological research to better understand cell physiology under real microgravity. Whereas specialized studies in space remain out of our reach, preliminary experiments can be performed on Earth under simulated microgravity (sµg). Based on this concept, we used a 3D-clinostat (3D-C) to analyze the effect of short exposure to sµg on human keratinocytes HaCaT and melanoma cells A375 cultured on all-glass Lab-on-a-Chip (LOC). Our preliminary studies included viability evaluation, mitochondrial and caspase activity, and proliferation assay, enabling us to determine the effect of sµg on human cells. By comparing the results concerning cells cultured on LOCs and standard culture dishes, we were able to confirm the biocompatibility of all-glass LOCs and their potential application in microgravity research on selected human cell lines. Our studies revealed that HaCaT and A375 cells are susceptible to simulated microgravity; however, we observed an increased caspase activity and a decrease of proliferation in cancer cells cultured on LOCs in comparison to standard cell cultures. These results are an excellent basis to conduct further research on the possible application of LOCs systems in cancer research in space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
CubeSat evolution: Analyzing CubeSat capabilities for conducting science missions
Poghosyan, A., & Golkar, A. (2017) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2016.11.002 · Cited by 537 · cited 2×
“While sounding rockets and parabolic flights allow to conduct quite sizeable experiments exceeding the size of 10 cm × 10 cm × 10 cm cubic units, it remains a basic unit of the research nanosatellites CubeSat [32,33], as well as the ICE Cubes Service-cubic experiments placed on the ISS to carry our investigations in r…”
BackgroundRevisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
The rate of oxygen utilization by cells
Wagner, B. A., Venkataraman, S., & Buettner, G. R. (2011) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2011.05.024 · Cited by 363
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277 · cited 1×
“Looking forward, the presented LOCs could be placed in a portable bioreactor with a microfluidic system and automated administration of reagents while the all-glass transparent structure of our LOCs facilitates the use of cameras and microsensors [1,69].”
MethodEvolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
The Evolution of Polystyrene as a Cell Culture Material
Lerman, M. J., Lembong, J., Muramoto, S., Gillen, G., & Fisher, J. P. (2018) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2018.0056 · Cited by 258
Cited by
The Fight against Cancer by Microgravity: The Multicellular Spheroid as a Metastasis Model
Grimm, D. G., Schulz, H., Krüger, M., Cortés-Sánchez, J. L., Egli, M., Kraus, A., Sahana, J., Corydon, T. J., Hemmersbach, R., Wise, P. M., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23063073 · Cited by 79
Development of lab-on-chip biosensor for the detection of toxic heavy metals: A review
Karthik, V., Karuna, B., Kumar, P. S., Saravanan, A., & Hemavathy, R. V. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.134427 · Cited by 77
Lab-on-a-chip systems for cancer biomarker diagnosis
Özyurt, C., Uludağ, İ., İnce, B., & Sezgintürk, M. K. (2023) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2023.115266 · Cited by 72
Lab-on-chip technologies for space research — current trends and prospects
Krakos, A. (2023) · Microchimica Acta · doi:10.1007/s00604-023-06084-4 · Cited by 45
Small tissue chips with big opportunities for space medicine
Mu, X., He, W., Rivera, V. A. M., Alba, R. A. D. D., Newman, D. J., & Zhang, Y. S. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.09.002 · Cited by 40
Metadata
- Authors
- Przystupski, D., Górska, A., Michel, O., Podwin, A., Śniadek, P., Łapczyński, R., Saczko, J., & Kulbacka, J.
- Affiliations
- Wroclaw Medical University (PL)
- University of Wrocław (PL)
- Wrocław University of Science and Technology (PL)
- SatRevolution S.A, Stabłowicka 147, 54-066 Wroclaw, Poland
- Corresponding author
- Michel, Olga
- ORCID
- Venue
- Cancers
- Publisher
- MDPI AG
- Published
- 2021-01-22
- Volume
- 13
- Issue
- 3
- Pages
- 402
- ISSN
- 2072-6694 (ISSN-L)
- PMC
- PMC7866167
- OpenAlex
- W3122417868
- Cited by
- 29
- References
- 77
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 4 · 2023: 6 · 2022: 10 · 2021: 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Cancers (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowe Centrum Badań i Rozwoju (POIR.04.01.01-00-0010/19-00)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- lab-on-a-chip, simulated microgravity, melanoma cells, A375 cells, HaCaT keratinocytes, biocompatibility, caspase activity, mitochondrial activity, cell proliferation, space biology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testing Lab-on-a-Chip Technology for Culturing Human Melanoma Cells under Simulated Microgravity. https://app.cochat.ai/papers/10.3390/cancers13030402
- The paper
- Przystupski, D., Górska, A., Michel, O., Podwin, A., Śniadek, P., Łapczyński, R., Saczko, J., & Kulbacka, J. (2021). Testing Lab-on-a-Chip Technology for Culturing Human Melanoma Cells under Simulated Microgravity. Cancers. https://doi.org/10.3390/cancers13030402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.