CoChat

Analysis of Artificial Intelligence-Based Approaches Applied to Non-Invasive Imaging for Early Detection of Melanoma: A Systematic Review

Open access
Patel, Raj H., Foltz, Emilie A., Witkowski, Alexander, Ludzik, Joanna · 2023 · Cancers
Cited by 82

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background: Melanoma, the deadliest form of skin cancer, poses a significant public health challenge worldwide. Early detection is crucial for improved patient outcomes. Non-invasive skin imaging techniques allow for improved diagnostic accuracy; however, their use is often limited due to the need for skilled practitioners trained to interpret images in a standardized fashion. Recent innovations in artificial intelligence (AI)-based techniques for skin lesion image interpretation show potential for the use of AI in the early detection of melanoma. Objective: The aim of this study was to evaluate the current state of AI-based techniques used in combination with non-invasive diagnostic imaging modalities including reflectance confocal microscopy (RCM), optical coherence tomography (OCT), and dermoscopy. We also aimed to determine whether the application of AI-based techniques can lead to improved diagnostic accuracy of melanoma. Methods: A systematic search was conducted via the Medline/PubMed, Cochrane, and Embase databases for eligible publications between 2018 and 2022. Screening methods adhered to the 2020 version of the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Included studies utilized AI-based algorithms for melanoma detection and directly addressed the review objectives. Results: We retrieved 40 papers amongst the three databases. All studies directly comparing the performance of AI-based techniques with dermatologists reported the superior or equivalent performance of AI-based techniques in improving the detection of melanoma. In studies directly comparing algorithm performance on dermoscopy images to dermatologists, AI-based algorithms achieved a higher ROC (>80%) in the detection of melanoma. In these comparative studies using dermoscopic images, the mean algorithm sensitivity was 83.01% and the mean algorithm specificity was 85.58%. Studies evaluating machine learning in conjunction with OCT boasted accuracy of 95%, while studies evaluating RCM reported a mean accuracy rate of 82.72%. Conclusions: Our results demonstrate the robust potential of AI-based techniques to improve diagnostic accuracy and patient outcomes through the early identification of melanoma. Further studies are needed to assess the generalizability of these AI-based techniques across different populations and skin types, improve standardization in image processing, and further compare the performance of AI-based techniques with board-certified dermatologists to evaluate clinical applicability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/cancers15194694

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 82

Metadata

Authors
Patel, R. H., Foltz, E. A., Witkowski, A., & Ludzik, J.
Venue
Cancers
Publisher
MDPI AG
Published
2023-09-23
Volume
15
Issue
19
Pages
4694
ISSN
2072-6694 (ISSN-L)
OpenAlex
W4386996094
Cited by
82
References
9
FWCI
3.94
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.