CoChat

Performance Evaluation of a Small-Scale Latent Heat Thermal Energy Storage Unit for Heating Applications Based on a Nanocomposite Organic PCM

Open access

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

A small-scale latent heat thermal energy storage (LHTES) unit for heating applications was studied experimentally using an organic phase change material (PCM). The unit comprised of a tank filled with the PCM, a staggered heat exchanger (HE) for transferring heat from and to the PCM, and a water pump to circulate water as a heat transfer fluid (HTF). The performance of the unit using the commercial organic paraffin A44 was studied in order to understand the thermal behavior of the system and the main parameters that influence heat transfer during the PCM melting and solidification processes. The latter will assist the design of a large-scale unit. The effect of flow rate was studied given that it significantly affects charging (melting) and discharging (solidification) processes. In addition, as organic PCMs have low thermal conductivity, the possible improvement of the PCM’s thermal behavior by means of nanoparticle addition was investigated. The obtained results were promising and showed that the use of graphite-based nanoplatelets improves the PCM thermal behavior. Charging was clearly faster and more efficient, while with the appropriate tuning of the HTF flow rate, an efficient discharging was accomplished.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/chemengineering3040088

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Test rig hydraulic drawing. Figure 1. Test rig hydraulic drawing.
Figure 1 Test rig hydraulic drawing. Figure 1. Test rig hydraulic drawing.CC-BY · From the PDF
Figure 2 Heat exchanger photo ( left ) and drawing ( right ). Figure 2. Heat exchanger photo ( left ) and drawing ( right ). Figure 2. Heat exchanger photo ( left ) and drawing ( right ).
Figure 2 Heat exchanger photo ( left ) and drawing ( right ). Figure 2. Heat exchanger photo ( left ) and drawing ( right ). Figure 2. Heat exchanger photo ( left ) and drawing ( right ).CC-BY · From the PDF
Figure 3 Thermocouples position and tank insulation. Figure 3. Thermocouples position and tank insulation. Figure 3. Thermocouples position and tank insulation.
Figure 3 Thermocouples position and tank insulation. Figure 3. Thermocouples position and tank insulation. Figure 3. Thermocouples position and tank insulation.CC-BY · From the PDF
Figure 4 Differential scanning calorimetry (DSC) results of A44 on heating and cooling cycle under 0.8 °C/min and 2.0 °C/min. Figure 4. Di erential scanning calorimetry (DSC) results of A44 on heating and cooling cycle under 0.8 C / min and 2.0 C / min.
Figure 4 Differential scanning calorimetry (DSC) results of A44 on heating and cooling cycle under 0.8 °C/min and 2.0 °C/min. Figure 4. Di erential scanning calorimetry (DSC) results of A44 on heating and cooling cycle under 0.8 C / min and 2.0 C / min.CC-BY · From the PDF
Figure 5 Comparison of the inlet and outlet water temperatures of the two same experiments A and B with 30 L/h flow rate. Figure 5. Comparison of the inlet and outlet water temperatures of the two same experiments A and B with 30 L / h flow rate.
Figure 5 Comparison of the inlet and outlet water temperatures of the two same experiments A and B with 30 L/h flow rate. Figure 5. Comparison of the inlet and outlet water temperatures of the two same experiments A and B with 30 L / h flow rate.CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 The interior of the tank filled with the PCM nanocomposite and the heat exchanger during the transducers' operation. Figure 7. The interior of the tank filled with the PCM nanocomposite and the heat exchanger during the transducers' operation.
Figure 7 The interior of the tank filled with the PCM nanocomposite and the heat exchanger during the transducers' operation. Figure 7. The interior of the tank filled with the PCM nanocomposite and the heat exchanger during the transducers' operation.CC-BY · From the PDF
Figure 8 Mean temperature profiles of A44 for charging and discharging and three HTF flow rates. Figure 8. Mean temperature profiles of A44 for charging and discharging and three HTF flow rates.
Figure 8 Mean temperature profiles of A44 for charging and discharging and three HTF flow rates. Figure 8. Mean temperature profiles of A44 for charging and discharging and three HTF flow rates.CC-BY · From the PDF
Image 9
CC-BY · From the PDF
Figure 10 Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon charging. Figure 10. Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon charging. ChemEngineering 2019 , 3 , x FOR PEER REVIEW 13 of 16
Figure 10 Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon charging. Figure 10. Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon charging. ChemEngineering 2019 , 3 , x FOR PEER REVIEW 13 of 16CC-BY · From the PDF
Figure 11 Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon discharging. Figure 11. Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon discharging.
Figure 11 Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon discharging. Figure 11. Comparison of HTF temperature evolution in case of pure A44 and A44 with nano-particles (A44 + NP) upon discharging.CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Figure 13 Mean temperature evolution of pure A44 and A44 + NP upon discharging. Figure 13. Mean temperature evolution of pure A44 and A44 + NP upon discharging.
Figure 13 Mean temperature evolution of pure A44 and A44 + NP upon discharging. Figure 13. Mean temperature evolution of pure A44 and A44 + NP upon discharging.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 14

Metadata

Authors
Koukou, M. K., Dogkas, G., Vrachopoulos, M. G., Konstantaras, J., Pagkalos, C., Lymperis, K., Stathopoulos, V., Evangelakis, G., Prouskas, C., Coelho, L., & Rebola, A.
Affiliations
  • National and Kapodistrian University of Athens (GR)
  • Z&X Mechanical Installations Ltd., 12 Agapinoros Street, 8049 Paphos, Cyprus
  • University of Ioannina (GR)
  • Polytechnic Institute of Setubal-IPS, 2910-761 Setúbal, Portugal
Corresponding author
Koukou, Maria K.
Venue
ChemEngineering
Publisher
MDPI AG
Published
2019-11-01
Volume
3
Issue
4
Pages
88
ISSN
2305-7084 (ISSN-L)
OpenAlex
W2989153716
Cited by
13
References
38
Citations by year
2025: 2 · 2023: 1 · 2022: 2 · 2021: 6 · 2020: 2
FWCI
1.41
Type
journal article
Language
en
Open access
Locations
  • ChemEngineering (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
TESSE2B PROJECT HORIZON (680555)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Solar Thermal and Photovoltaic Systems
Keywords
latent heat storage, organic phase change materials, graphite nanoplatelets, heating applications, heat transfer fluid flow rate, PCM melting and solidification, thermal conductivity enhancement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.