Cited by 11Medical Image Segmentation TechniquesArtificial Intelligence in Healthcare and EducationAI in cancer detection

The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index, and 1 are not checked yet.

HaTU-Net: Harmonic Attention Network for Automated Ovarian Ultrasound Quantification in Assisted Pregnancy

Open access
Singh, Vivek Kumar, Yousef Kalafi, Elham, Cheah, Eugene, Wang, Shuhang, Wang, Jingchao, Ozturk, Arinc, Li, Qian, Eldar, Yonina C., Samir, Anthony E., Kumar, Viksit·2022·Diagnostics

Abstract

Antral follicle Count (AFC) is a non-invasive biomarker used to assess ovarian reserves through transvaginal ultrasound (TVUS) imaging. Antral follicles’ diameter is usually in the range of 2–10 mm. The primary aim of ovarian reserve monitoring is to measure the size of ovarian follicles and the number of antral follicles. Manual follicle measurement is inhibited by operator time, expertise and the subjectivity of delineating the two axes of the follicles. This necessitates an automated framework capable of quantifying follicle size and count in a clinical setting. This paper proposes a novel Harmonic Attention-based U-Net network, HaTU-Net, to precisely segment the ovary and follicles in ultrasound images. We replace the standard convolution operation with a harmonic block that convolves the features with a window-based discrete cosine transform (DCT). Additionally, we proposed a harmonic attention mechanism that helps to promote the extraction of rich features. The suggested technique allows for capturing the most relevant features, such as boundaries, shape, and textural patterns, in the presence of various noise sources (i.e., shadows, poor contrast between tissues, and speckle noise). We evaluated the proposed model on our in-house private dataset of 197 patients undergoing TransVaginal UltraSound (TVUS) exam. The experimental results on an independent test set confirm that HaTU-Net achieved a Dice coefficient score of 90% for ovaries and 81% for antral follicles, an improvement of 2% and 10%, respectively, when compared to a standard U-Net. Further, we accurately measure the follicle size, yielding the recall, and precision rates of 91.01% and 76.49%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/diagnostics12123213

Cites

35 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Two included studies, of which one had a prospective, randomized-controlled design, showed increased accuracy of follicle evaluation by using AI-assisted 2D and 3D US.

    “Two included studies, of which one had a prospective, randomized-controlled design, showed increased accuracy of follicle evaluation and reduced examination time by using AI-assisted 2D and 3D US [222,223].”

    From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [222]

    The Results (section 3.3; page unavailable) report improved follicle segmentation with HaTU-Net compared with U-Net, supporting increased accuracy for AI-assisted ultrasound analysis. The Dataset section (2.1; page unavailable) describes this study as retrospective and based on static ultrasound images; it does not establish that this study was randomized or evaluated 3D ultrasound. The prospective randomized study mentioned in the citing sentence may be the other cited study. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • Two included studies showed reduced examination time by using AI-assisted 2D and 3D US for follicle evaluation.

    “Two included studies, of which one had a prospective, randomized-controlled design, showed increased accuracy of follicle evaluation and reduced examination time by using AI-assisted 2D and 3D US [222,223].”

    From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [222]

    The Introduction (page unavailable) says manual follicle measurement is time-consuming and proposes automation to improve clinical flow. But the Methods describe a retrospective analysis of ultrasound images, and the Results report segmentation performance, not a measured reduction in examination time. This source therefore supports AI-assisted follicle evaluation, but not the claimed time saving or a prospective randomized comparison of 2D and 3D ultrasound. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Flagged first, then by citations

Research works printed but not linked: 3

  1. Oktay, O., Schlemper, J., Folgoc, L.L., Lee, M., Heinrich, M., Misawa, K., Mori, K., McDonagh, S., Hammerla, N.Y., and Kainz, B. (2018). Attention u-net: Learning where to look for the pancreas. arXiv.
  2. Jose, J.M., Sindagi, V., Hacihaliloglu, I., and Patel, V.M. (2020). KiU-Net: Towards accurate segmentation of biomedical images using over-complete representations. arXiv.
  3. Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., and Antiga, L. (2019). Pytorch: An imperative style, high-performance deep learning library. arXiv.

Cited by

Sorted by citations

Metadata

Authors
Singh, V. K., Yousef Kalafi, E., Cheah, E., Wang, S., Wang, J., Ozturk, A., Li, Q., Eldar, Y. C., Samir, A. E., & Kumar, V.
Affiliations
  • Harvard University (US)
  • Center for Ultrasound Research & Translation at the Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA 02114, USA
  • Third Hospital of Hebei Medical University (CN)
  • Weizmann Institute of Science (IL)
Corresponding author
Kumar, Viksit
Venue
Diagnostics
Publisher
MDPI AG
Published
2022-12-18
Volume
12
Issue
12
Pages
3213
ISSN
2075-4418 (ISSN-L)
OpenAlex
W4312141010
Cited by
11
References
35
Citations by year
2026: 1 · 2025: 5 · 2024: 4 · 2023: 1
FWCI
0.82
Type
journal article
Language
en
Open access
Locations
  • Diagnostics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
Keywords
antral follicle count, ovarian reserve, transvaginal ultrasound, discrete cosine transform, assisted reproduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review