Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i
Abstract
ImmunoCAP ISAC E112i (ISAC) and Allergy Explorer 2 (ALEX2) detect specific immunoglobulin E (IgE) reactivity. Both multiplex assays contain molecular allergens and ALEX2 additionally includes allergen extracts and inhibitors that block the binding of IgE to cross-reacting carbohydrate determinants (CCDs). This study aimed to compare the performance of ISAC and ALEX2 by determining the IgE reactivity against allergen extracts and/or allergen components and by using qualitative, semiquantitative, and quantitative analyses of all comparable allergen components in sera from 216 participants recruited in South Tyrol/Italy. For extract sensitization in ALEX2, the analysis revealed negative corresponding allergen components in 18.4% and at least one positive corresponding allergen component in 81.6% of all cases. For ISAC, the corresponding results were 23.5% and 76.5% of cases, respectively. The ALEX2 CCD inhibitor eliminated CCD-positive signals detected by ISAC in 88.5% of cases. Based on sensitization values of 0.3–14.9 ISU or kUA/L, there was good agreement between ALEX2 and ISAC, although ALEX2 showed higher values than ISAC. The addition of allergen-extract tests in ALEX2 resulted in the detection of more sensitizations than with corresponding allergen components alone. In the range of <15 ISU or kUA/L, ALEX2 may be more effective in detecting sensitizations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Unlike ISAC, ALEX includes cross-reactivity inhibition, which minimizes false positives from panallergens like profilins and CCDs (cross-reactive carbohydrate determinants) [201].”
From Pollen–Food Allergy Syndrome: Allergens, Clinical Insights, Diagnostic and Therapeutic Challenges (2024) · cites this paper as [201]
In the citing paper
“ISAC (Immuno Solid-Phase Allergen Chip; ThermoFisher Scientific, Waltham, MA, USA) is a multiplex diagnostic platform that tests for IgE to over 100 allergenic components simultaneously [201].”
From Pollen–Food Allergy Syndrome: Allergens, Clinical Insights, Diagnostic and Therapeutic Challenges (2024) · cites this paper as [201]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Research works printed but not linked: 17
- Steering Committee Authors, and Review Panel Members (2020). A WAO—ARIA—GA2LEN consensus document on molecular-based allergy diagnosis (PAMD@): Update 2020. World Allergy Organ J., 13, 100091. · DOI · Paper page
- Matricardi, 2016, Molecular allergology between precision medicine and the choosing wisely initiative, Clin. Exp. Allergy, 46, 664, 10.1111/cea.12679 · DOI
- Incorvaia, 2021, Personalized medicine for allergy treatment: Allergen immunotherapy still a unique and unmatched model, Allergy, 76, 1041, 10.1111/all.14575 · DOI
- Hoffmann, K., Hilger, C., Santos, A., de las Vecillas, L., and Dramburg, S. (2022). Molecular Allergology User’s Guide 2.0, John Wiley & Sons Ltd. · DOI
- Barber, 2021, Molecular allergology and its impact in specific allergy diagnosis and therapy, Allergy, 76, 3642, 10.1111/all.14969 · DOI · Paper page
- Jordakieva, 2018, Allergy diagnosis from symptoms to molecules, or from molecules to symptoms: A comparative clinical study, World Allergy Organ. J., 11, 22, 10.1186/s40413-018-0199-y · DOI
- Jakob, 2015, Molecular allergy diagnostics using multiplex assays: Methodological and practical considerations for use in research and clinical routine. Part 21 of the Series Molecular Allergology, Allergo J. Int., 24, 320, 10.1007/s40629-015-0087-8 · DOI
- Scala, 2021, A qualitative and quantitative comparison of IgE antibody profiles with two multiplex platforms for component-resolved diagnostics in allergic patients, Clin. Exp. Allergy, 51, 1603, 10.1111/cea.14016 · DOI
- Diem, 2022, Real-life evaluation of molecular multiplex IgE test methods in the diagnosis of pollen associated food allergy, Allergy, 77, 3028, 10.1111/all.15329 · DOI
- Platteel, 2022, A comprehensive comparison between ISAC and ALEX2 multiplex test systems, Clin. Chem. Lab. Med., 60, 1046, 10.1515/cclm-2022-0191 · DOI
- Quan, 2022, Validation of a commercial allergen microarray platform for specific immunoglobulin E detection of respiratory and plant food allergens, Ann. Allergy Asthma Immunol., 128, 283, 10.1016/j.anai.2021.11.019 · DOI
- Lu, 2016, Sample size for assessing agreement between two methods of measurement by Bland−Altman method, Int. J. Biostat., 12, 1, 10.1515/ijb-2015-0039 · DOI
- Schober, 2018, Correlation coefficients: Appropriate use and interpretation, Anesth. Analg., 126, 1763, 10.1213/ANE.0000000000002864 · DOI · Paper page
- McBride, 2005, A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient. HAM2005-062, NIWA Client. Rep., 45, 307
- Nerelius, 2020, Comparative study of Allergy Explorer (ALEX) versus ImmunoCAP platforms, Russ. J. Allergy, 17, 66, 10.36691/RAJ.2.020.17.1.007 · DOI
- Heffler, 2018, Extended IgE profile based on an allergen macroarray: A novel tool for precision medicine in allergy diagnosis, World Allergy Organ. J., 11, 7, 10.1186/s40413-018-0186-3 · DOI
- Bojcukova, 2019, Comparison of two multiplex arrays in the diagnostics of allergy, Clin. Transl. Allergy, 9, 31, 10.1186/s13601-019-0270-y · DOI
Cited by
Sorted by citations
Pollen–Food Allergy Syndrome: Allergens, Clinical Insights, Diagnostic and Therapeutic Challenges
Haidar, L., Bănărescu, C. F., Uța, C., Moldovan, S. I., Zimbru, E.-L., Zimbru, R.-I., Ciurariu, E., Georgescu, M., & Panaitescu, C. (2024) · Applied Sciences · doi:10.3390/app15010066 · Cited by 21
Metadata
- Authors
- Nösslinger, H., Mair, E., Oostingh, G. J., Ahlgrimm-Siess, V., Ringauf, A., & Lang, R.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2024-05-08
- Volume
- 14
- Issue
- 10
- Pages
- 976
- ISSN
- 2075-4418
- PMC
- PMC11119049
- Cited by
- 21
- References
- 1
- Language
- en
- Funders
- South Tyrolean Fund for the Promotion of Scientific Research (SFPR) at the South Tyrolean Health Care Service (SABES)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i. https://app.cochat.ai/papers/10.3390/diagnostics14100976
- The paper
- Nösslinger, H., Mair, E., Oostingh, G. J., Ahlgrimm-Siess, V., Ringauf, A., & Lang, R. (2024). Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i. Diagnostics. https://doi.org/10.3390/diagnostics14100976