CoChat

FDA-Approved Artificial Intelligence and Machine Learning (AI/ML)-Enabled Medical Devices: An Updated Landscape

Open access

Published version of a preprint

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

As artificial intelligence (AI) has been highly advancing in the last decade, machine learning (ML)-enabled medical devices are increasingly used in healthcare. In this study, we collected publicly available information on AI/ML-enabled medical devices approved by the FDA in the United States, as of the latest update on 19 October 2023. We performed comprehensive analysis of a total of 691 FDA-approved artificial intelligence and machine learning (AI/ML)-enabled medical devices and offer an in-depth analysis of clearance pathways, approval timeline, regulation type, medical specialty, decision type, recall history, etc. We found a significant surge in approvals since 2018, with clear dominance of the radiology specialty in the application of machine learning tools, attributed to the abundant data from routine clinical data. The study also reveals a reliance on the 510(k)-clearance pathway, emphasizing its basis on substantial equivalence and often bypassing the need for new clinical trials. Also, it notes an underrepresentation of pediatric-focused devices and trials, suggesting an opportunity for expansion in this demographic. Moreover, the geographical limitation of clinical trials, primarily within the United States, points to a need for more globally inclusive trials to encompass diverse patient demographics. This analysis not only maps the current landscape of AI/ML-enabled medical devices but also pinpoints trends, potential gaps, and areas for future exploration, clinical trial practices, and regulatory approaches. In conclusion, our analysis sheds light on the current state of FDA-approved AI/ML-enabled medical devices and prevailing trends, contributing to a wider comprehension.

Overview

Integrity signals

Registry

Crossref · 10.3390/electronics13030498

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Cited by

See all 294

Metadata

Authors
Joshi, G., Jain, A., Araveeti, S. R., Adhikari, S., Garg, H., & Bhandari, M.
Affiliations
  • The University of Texas at San Antonio Health Science Center (US)
  • New England College (US)
  • Texas A&M University (US)
Corresponding author
Bhandari, Mukund
Venue
Electronics
Publisher
MDPI AG
Published
2024-01-24
Volume
13
Issue
3
Pages
498
ISSN
2079-9292 (ISSN-L)
OpenAlex
W4391221083
Cited by
294
References
18
Citations by year
2026: 75 · 2025: 110 · 2024: 88
FWCI
25.57
Type
journal article
Language
en
Open access
Locations
  • Electronics (publishedVersion, cc-by)
  • medRxiv (acceptedVersion, cc-by-nd)
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
  • Physical Sciences › Computer Science › Information Systems › Internet of Things and AI
Keywords
FDA device approval, 510(k) clearance, substantial equivalence, medical device regulation, radiology, diversity in clinical trials, medical device recall

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.