Overview of AC Microgrid Controls with Inverter-Interfaced Generations
Open accessThe DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
Distributed generation (DG) is one of the key components of the emerging microgrid concept that enables renewable energy integration in a distribution network. In DG unit operation, inverters play a vital role in interfacing energy sources with the grid utility. An effective interfacing can successfully be accomplished by operating inverters with effective control techniques. This paper reviews and categorises different control methods (voltage and primary) for improving microgrid power quality, stability and power sharing approaches. In addition, the specific characteristics of microgrids are summarised to distinguish from distribution network control. Moreover, various control approaches including inner-loop controls and primary controls are compared according to their relative advantages and disadvantages. Finally, future research trends for microgrid control are discussed pointing out the research opportunities. This review paper will be a good basis for researchers working in microgrids and for industry to implement the ongoing research improvement in real systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 1×
“It has another inherent drawback between the voltage regulation and power sharing [28,97].”
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 1×
“The different control approaches can be applied to various reference frames [38].”
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 1×
“Q ) control coupling, voltage and frequency deviation, dependence on network impedance, and issues with non-linear loads and accuracy [85–88].”
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 1×
“Although some of the research work is presented to increase the response time of the DG units by applying flywheel and/or mimicking synchronous generators [123–129], there are still opportunities for researchers to further examine the microgrid with improved inertia.”
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 1×
“The selection of Kv and K f have an influence on system stability [95,96].”
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312 · cited 1×
“The grid-following operating mode, sometimes denoted as grid feeding and PQ control [12,13], is achieved by current source inverters (CSIs).”
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Cited by
Microgrids: A review, outstanding issues and future trends
Uddin, M., Mo, H., Dong, D., Elsawah, S., Zhu, J., & Guerrero, J. M. (2023) · Energy Strategy Reviews · doi:10.1016/j.esr.2023.101127 · Cited by 455
High-Level Penetration of Renewable Energy Sources Into Grid Utility: Challenges and Solutions
Alam, M. S., Al-Ismail, F. S., Salem, A., & Abido, M. A. (2020) · IEEE Access · doi:10.1109/access.2020.3031481 · Cited by 431
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Self-citation
Metadata
- Authors
- Hossain, M., Pota, H., Issa, W., & Hossain, M.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2017-08-30
- Volume
- 10
- Issue
- 9
- Pages
- 1300
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2751155104
- Cited by
- 205
- References
- 80
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.