Comparative Study of Ramp-Rate Control Algorithms for PV with Energy Storage Systems
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The high variability of solar irradiance, originated by moving clouds, causes fluctuations in Photovoltaic (PV) power generation, and can negatively impact the grid stability. For this reason, grid codes have incorporated ramp-rate limitations for the injected PV power. Energy Storage Systems (ESS) coordinated by ramp-rate (RR) control algorithms are often applied for mitigating these power fluctuations to the grid. These algorithms generate a power reference to the ESS that opposes the PV fluctuations, reducing them to an acceptable value. Despite their common use, few performance comparisons between the different methods have been presented, especially from a battery status perspective. This is highly important, as different smoothing methods may require the battery to operate at different regimes (i.e., number of cycles and cycles deepness), which directly relates to the battery lifetime performance. This paper intends to fill this gap by analyzing the different methods under the same irradiance profile, and evaluating their capability to limit the RR and maintain the battery State of Charge (SOC) at the end of the day. Moreover, an analysis into the ESS capacity requirements for each of the methods is quantified. Finally, an analysis of the battery cycles and its deepness is performed based on the well-established rainflow cycle counting method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental Validation of a Battery Dynamic Model for EV Applications
Tremblay, O., & Dessaint, L.-A. (2009) · World Electric Vehicle Journal · doi:10.3390/wevj3020289 · Cited by 1,223 · cited 2×
“The battery pack model was implemented based on the empirical model for Li-Ion batteries presented in [27], which follows Shepherd ́s equation for battery voltage estimation [28].”
MethodHohm, D. P., & Ropp, M. E. (2002) · Conference Record of the Twenty-Eighth IEEE Photovoltaic Specialists Conference - 2000 (Cat. No.00CH37036) · doi:10.1109/pvsc.2000.916230 · Cited by 576 · cited 1×
“One converter is responsible for the PV boost stage, and controlled by a maximum power point tracking (MPPT) based on the Perturb & Observe (P&O) method [25,26].”
MethodDesign of Primary and Secondary Cells
Shepherd, C. M. (1965) · Journal of The Electrochemical Society · doi:10.1149/1.2423659 · Cited by 510 · cited 1×
“The battery pack model was implemented based on the empirical model for Li-Ion batteries presented in [27], which follows Shepherd ́s equation for battery voltage estimation [28].”
MethodStandardization of the rainflow counting method for fatigue analysis
AMZALLAG, C., GEREY, J., ROBERT, J., & BAHUAUD, J. (1994) · International Journal of Fatigue · doi:10.1016/0142-1123(94)90343-3 · Cited by 488 · cited 1×
“In order to quantify the cycles number and their deepness, the rainflow cycle counting method, proposed in [32] for fatigue analysis and reproduce for battery applications, is used.”
MethodOmran, W. A., Kazerani, M., & Salama, M. M. A. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2010.2062515 · Cited by 395 · cited 1×
“Other possibility relies on constraining the maximum power point (MPP) by modifying the traditional maximum power point tracker (MPPT) algorithms [9,10].”
Method(2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2304951 · Cited by 332 · cited 3×
“Previous publications [22] and [20] proposed a moving average window of 20 minutes for a 4 kW and 1 kW PV system, respectively, while, in [23] and [16], a 16-minute and 15-minute moving average for a 10 MW and 500 kW PV plant are considered.”
BackgroundMethodYang, Y., Enjeti, P., Blaabjerg, F., & Wang, H. (2015) · IEEE Industry Applications Magazine · doi:10.1109/mias.2014.2345837 · Cited by 262
Ramp-Rate Control of Photovoltaic Generator With Electric Double-Layer Capacitor
Kakimoto, N., Satoh, H., Takayama, S., & Nakamura, K. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2001580 · Cited by 194 · cited 2×
“Previous publications [22] and [20] proposed a moving average window of 20 minutes for a 4 kW and 1 kW PV system, respectively, while, in [23] and [16], a 16-minute and 15-minute moving average for a 10 MW and 500 kW PV plant are considered.”
BackgroundMethodReview of PREPA Technical Requirements for Interconnecting Wind and Solar Generation
Gevorgian, V., & Booth, S. (2013) · doi:10.2172/1260328 · Cited by 187 · cited 4×
“For Germany [6] and Puerto Rico (PREPA) [5], a maximum ramp-rate of 10%/minute of the rated PV power is considered.”
BackgroundMethodInfluentialChina's renewable energy goals by 2050
Yang, X. J., Hu, H., Tan, T., & Li, J. (2016) · Environmental Development · doi:10.1016/j.envdev.2016.10.001 · Cited by 184 · cited 1×
“This represents less than two percent of the worldwide electricity demand, but when compared to the ambition of China alone, of 1300 GW of solar capacity by the year of 2055 [2], illustrates what is yet to come for PV energy systems.”
Background
Cited by
Nanoferrites heterogeneous catalysts for biodiesel production from soybean and canola oil: a review
Naagar, M., Chalia, S., Thakur, P., Sridhara, S. N., Thakur, A., & Sharma, P. B. (2021) · Environmental Chemistry Letters · doi:10.1007/s10311-021-01247-2 · Cited by 93
Metadata
- Authors
- Martins, J., Spataru, S., Sera, D., Stroe, D.-I., & Lashab, A.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2019-04-08
- Volume
- 12
- Issue
- 7
- Pages
- 1342
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2905213697
- Cited by
- 237
- References
- 20
- FWCI
- 16.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.