Machine learning (ML) is becoming a key enabler in building energy management systems (BEMS), yet most existing reviews focus on simulations and fail to reflect the realities of real-world deployment. In response to this limitation, the present work aims to present a systematic review dedicated entirely to experimental, field-tested applications of ML in BEMS, covering systems such as Heating, Ventilation & Air-conditioning (HVAC), Renewable Energy Systems (RES), Energy Storage Systems (ESS), Ground Heat Pumps (GHP), Domestic Hot Water (DHW), Electric Vehicle Charging (EVCS), and Lighting Systems (LS). A total of 73 real-world deployments are analyzed, featuring techniques like Model Predictive Control (MPC), Artificial Neural Networks (ANNs), Reinforcement Learning (RL), Fuzzy Logic Control (FLC), metaheuristics, and hybrid approaches. In order to cover both methodological and practical aspects, and properly identify trends and potential challenges in the field, current review uses a unified framework: On the methodological side, it examines key-attributes such as algorithm design, agent architectures, data requirements, baselines, and performance metrics. From a practical standpoint, the study focuses on building typologies, deployment architectures, zones scalability, climate, location, and experimental duration. In this context, the current effort offers a holistic overview of the scientific landscape, outlining key trends and challenges in real-world machine learning applications for BEMS research. By focusing exclusively on real-world implementations, this study offers an evidence-based understanding of the strengths, limitations, and future potential of ML in building energy control—providing actionable insights for researchers, practitioners, and policymakers working toward smarter, grid-responsive buildings. Findings reveal a maturing field with clear trends: MPC remains the most deployment-ready, ANNs provide efficient forecasting capabilities, RL is gaining traction through safer offline–online learning strategies, FLC offers simplicity and interpretability, and hybrid methods show strong performance in multi-energy setups.

Checked 2026-11-24 · 1 reference not checked yet

Overview

CoChat Summary

TL;DR

This systematic review synthesizes 73 real-world, field-tested machine-learning applications for building energy management systems from 2015–2025, covering HVAC, RES, ESS, GHP, DHW, EVCS, and lighting. It finds MPC most deployment-ready, ANNs effective for forecasting, RL increasingly used with offline-online safety strategies, FLC valued for interpretability, and hybrids strong in multi-energy setups.

Key findings

  • Across the reviewed real-world deployments, Table 7 reports MPC 35, ANN 6, RL 8, FLC 8, hybrid 14, and other 3 applications; MPC is described as most frequent and deployment-ready, while RL remains limited by safety and data requirements.
  • Reported energy/cost savings vary by baseline: HVAC deployments often achieve 15–45%; office MPC 17–45%; residential 19–35%; campus/multi-building 10–30% cost reductions; gains are 20–50% against weak RBC/static baselines but typically below 10% against optimal or centralized MPC.
  • Temporal design converges on 5–15 min control intervals; MPC dominant forecast horizon is 24–48 h with 5–30 min timestep, RL 5–60 min, and FLC 1–30 min.
  • A common data hierarchy emerges: temperature/weather are nearly universal; occupancy/CO₂ add comfort intelligence; forecasts enable proactive control; DER and price signals enable flexibility and grid interaction.

Methods

  • PRISMA-guided systematic review; Scopus and Web of Science search from January 2015 to March 2025; English journal and full conference papers; included only ML-based control/optimization tested in real buildings (field pilot, living lab, or long-term experimental setup); simulation-only studies excluded unless directly benchmarked with field measurements; at least 10 citations required except relaxed for 2025.
  • Extracted methodological attributes (algorithm, agent architecture, forecast horizon/timestep, data, baseline, performance metrics) and practical attributes (implementation type, equipment, building typology, zone scalability, location/climate, experimental period); synthesis is descriptive quantitative, using simple relative frequencies, with no formal meta-analysis, imputation, or weighting.

Limitations

  • The paper states a formal meta-analysis was not possible because studies varied widely in building types, control goals, time horizons, and evaluation metrics; synthesis is descriptive only, with no imputation or weighting.
  • The paper states the evidence base is biased toward academic/lab/office testbeds; residential, small commercial, multi-building portfolios, multi-agent coordination, and long-term RL validation remain underexplored; standardized evaluation, baselines, and transferable models are lacking.
  • Evident from the text: geographic/climate concentration in Europe, Asia, and North America; the citation threshold may favor older/high-impact studies; Table 7 method counts sum to 74 while the abstract says 73 studies.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/en19010219

Cites

170 of 171 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Geographical distribution of real-world experiments for BEMS.
Figure 1 Geographical distribution of real-world experiments for BEMS.CC-BY · From the PDF
Figure 2 Left: Occurrences of ML-based control applications in real-world BEMS; Right: Real-world ML-based applications for BEMS per year.
Figure 2 Left: Occurrences of ML-based control applications in real-world BEMS; Right: Real-world ML-based applications for BEMS per year.CC-BY · From the PDF
Figure 3 Paper structure.
Figure 3 Paper structure.CC-BY · From the PDF
Identification of Studies via Databases & Registers
Identification of Studies via Databases & RegistersCC-BY · From the PDF
Figure 5 Reasons for controlling energy systems in the building environment.
Figure 5 Reasons for controlling energy systems in the building environment.CC-BY · From the PDF
Figure 6 Step-by-step control cycle of a modern building energy management system.
Figure 6 Step-by-step control cycle of a modern building energy management system.CC-BY · From the PDF
Figure 7 Left: Occurrence of ML types in in real-world BEMS applications; Right : Percentage (%) of MLtypes in in real-world BEMS applications.
Figure 7 Left: Occurrence of ML types in in real-world BEMS applications; Right : Percentage (%) of MLtypes in in real-world BEMS applications.CC-BY · From the PDF
Figure 8 Left: Occurrence of MPC types in real-world BEMS applications; Right: Occurrence of MPC solvers in real-world BEMS applications.
Figure 8 Left: Occurrence of MPC types in real-world BEMS applications; Right: Occurrence of MPC solvers in real-world BEMS applications.CC-BY · From the PDF
Figure 9 Left: Occurrence of ANN types in real-world BEMS applications; Center: Occurrence of RL types in real-world BEMS applications; Right: Occurrence of FLC types in real-world BEMS applications.
Figure 9 Left: Occurrence of ANN types in real-world BEMS applications; Center: Occurrence of RL types in real-world BEMS applications; Right: Occurrence of FLC types in real-world BEMS applications.CC-BY · From the PDF
Figure 10 Left: Occurrence of hybrid schemes in real-world BEMS applications; Right: Occurrence of hybrid counterparts in real-world BEMS applications.
Figure 10 Left: Occurrence of hybrid schemes in real-world BEMS applications; Right: Occurrence of hybrid counterparts in real-world BEMS applications.CC-BY · From the PDF
Figure 11 Left: Percentage (%) of single-agent vs. multi-agent real-world applications for BEMS; Right: Occurrence of multi-agent strategies (cooperative, hierarchical, fully decentralized) in realworld applications for BEMS.
Figure 11 Left: Percentage (%) of single-agent vs. multi-agent real-world applications for BEMS; Right: Occurrence of multi-agent strategies (cooperative, hierarchical, fully decentralized) in realworld applications for BEMS.CC-BY · From the PDF
Figure 12 Data cluster occurrence in real-world applications for BEMS.
Figure 12 Data cluster occurrence in real-world applications for BEMS.CC-BY · From the PDF
Figure 13 Left : Occurrence of baseline control methodologies in real-world applications for BEMS; Right : Percentage (%) of baseline control methodologies in real-world applications for BEMS.
Figure 13 Left : Occurrence of baseline control methodologies in real-world applications for BEMS; Right : Percentage (%) of baseline control methodologies in real-world applications for BEMS.CC-BY · From the PDF
Figure 14 Left: Performance metrics occurrences in real-world implementations for BEMS; Right: Performance metrics percentage (%) in real-world implementations for BEMS.
Figure 14 Left: Performance metrics occurrences in real-world implementations for BEMS; Right: Performance metrics percentage (%) in real-world implementations for BEMS.CC-BY · From the PDF
Figure 15 Left: Occurrence of implementation types in real-world BEMS applications; Right: Percentage (%) of implementation types in real-world BEMS applications.
Figure 15 Left: Occurrence of implementation types in real-world BEMS applications; Right: Percentage (%) of implementation types in real-world BEMS applications.CC-BY · From the PDF
Figure 16 Left : Occurrence of energy system types in real-world BEMS applications; Right : Percentage (%) of single-energy system vs. multi-energy system studies in real-world BEMS.
Figure 16 Left : Occurrence of energy system types in real-world BEMS applications; Right : Percentage (%) of single-energy system vs. multi-energy system studies in real-world BEMS.CC-BY · From the PDF
Figure 17 Left: Occurrences of building types in real-world BEMS applications; Right: Percentage (%) of operational vs. experimental building testbeds in real-world BEMS applications.
Figure 17 Left: Occurrences of building types in real-world BEMS applications; Right: Percentage (%) of operational vs. experimental building testbeds in real-world BEMS applications.CC-BY · From the PDF
Figure 18 Left : Occurrence of single- vs. multi-zone buildings in real-world BEMS applications; Right : Percentage (%) of single- vs. multi-zone buildings in real-world BEMS applications.
Figure 18 Left : Occurrence of single- vs. multi-zone buildings in real-world BEMS applications; Right : Percentage (%) of single- vs. multi-zone buildings in real-world BEMS applications.CC-BY · From the PDF
Figure 19 Left: Occurrences of real-world applications per country; Right: Percentage (%) of real-world applications (%) per continent.
Figure 19 Left: Occurrences of real-world applications per country; Right: Percentage (%) of real-world applications (%) per continent.CC-BY · From the PDF
Figure 20 Left: Climate distribution of real-world BEMS applications; Right: Climate-type distribution across real implementations.
Figure 20 Left: Climate distribution of real-world BEMS applications; Right: Climate-type distribution across real implementations.CC-BY · From the PDF
Figure 21 Left : Number of real-world applications considering the experimental duration; Right : Percentage (%) of real-world applications considering the experimental duration.
Figure 21 Left : Number of real-world applications considering the experimental duration; Right : Percentage (%) of real-world applications considering the experimental duration.CC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 7 Not valid · 162 Not checked · 188 Own results and interpretations

211 more claims

Create a free account to see all 357 claims and to verify the 374 references still open.

See all claims — free account
  • It may state two separate claims as one. 118
  • Probably not a substantial claim. 28
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

5 of 9 · the rest aren’t loaded

4 more findings

Create a free account to see every finding of this check.

See all findings — free account

Citations

Cites

Show all 171 references

Cited by

See all 26

Metadata

Authors
Michailidis, P., Minelli, F., Michailidis, I., Kurucan, M., Coban, H. H., & Kosmatopoulos, E.
Affiliations
  • Democritus University of Thrace (GR)
  • University of Naples Federico II (IT)
  • Adana Science and Technology University (TR)
  • Department of Electrical and Electronics Engineering, Bartin University, 74100 Bartın, Türkiye
Corresponding author
Michailidis, Panagiotis
Venue
Energies
Publisher
MDPI AG
Published
2025-12-31
Volume
19
Issue
1
Pages
219
ISSN
1996-1073 (ISSN-L)
OpenAlex
W7117727181
Cited by
26
References
169
Citations by year
2026: 26
FWCI
1.79
Type
journal article
Language
en
Open access
Locations
  • Energies (publishedVersion, cc-by)
  • Duraspace of Bartin University (Bartin University) (submittedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
Hellenic Foundation for Research and Innovation (16880)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
Keywords
building energy management systems, machine learning applications, HVAC control, renewable energy systems, energy storage systems, ground source heat pump, domestic hot water, electric vehicle charging, lighting systems, model predictive control, artificial neural networks, reinforcement learning, fuzzy logic control, metaheuristic optimization, hybrid control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-24, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-24 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.