Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus
Open accessThe DOI matches its Crossref record.
Abstract
The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The solutions to electric vehicle air conditioning systems: A review
Zhang, Z., Wang, J., Feng, X., Chang, L., Chen, Y., & Wang, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.04.005 · Cited by 283
Review of Cabin Thermal Management for Electrified Passenger Vehicles
Lajunen, A., Yang, Y., & Emadi, A. (2020) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2020.2988468 · Cited by 107
“demonstrated this when they evaluated the performance of a coolant-source heat pump in an electric bus [104].”
BackgroundŁebkowski, A. (2019) · Energies · doi:10.3390/en12050951 · Cited by 57
Metadata
- Authors
- Cho, C.-W., Lee, H.-S., Won, J.-P., & Lee, M.-Y.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2012-03-08
- Volume
- 5
- Issue
- 3
- Pages
- 658-669
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2024631681
- Cited by
- 60
- References
- 0
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus. https://app.cochat.ai/papers/10.3390/en5030658
- The paper
- Cho, C.-W., Lee, H.-S., Won, J.-P., & Lee, M.-Y. (2012). Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus. Energies. https://doi.org/10.3390/en5030658
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.