Cited by 5Infrared Thermography in MedicineThermography and Photoacoustic TechniquesThermoregulation and physiological responses

Study on Human Temperature Measurement by Infrared Thermography

Open access
Švantner, Michal, Lang, Vladislav, Kohlschutter, Tomáš, Skála, Jiří, Honner, Milan, Muzika, Lukáš, Kosová, Eliška·2021·The 16th International Workshop on Advanced Infrared Technology & Applications

Abstract

Increased temperature in humans is one of symptoms of infectious diseases. Infrared thermography is a popular method for measuring temperature as it offers fast and non-contact temperature measurement. However, and despite many advantages, its real accuracy for human temperature measurement is not sufficient in many cases. This study was focused on a statistical evaluation of human temperature measurement reliability. The goal of the experiment was to find limitations of thermography at near-laboratory conditions. More than 300 measurements were made simultaneously by a thermography and an arm-pit thermometer on a closed group of persons during several months. The results showed that standard deviations of the performed armpit and thermographic temperature measurement were about 0.15 and 0.36 °C, respectively, but that a temperature shift and a dependence on ambient conditions can occur due to the used experimental configuration.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/engproc2021008004

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A single temperature measurement can indicate whether a patient has fever or hypothermia.

    “A single temperature measurement can tell us whether the patient has a fever or hypothermia [150,151,152,153,154].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [152]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Švantner, M., Lang, V., Kohlschutter, T., Skála, J., Honner, M., Muzika, L., & Kosová, E.
Affiliations
  • University of West Bohemia in Pilsen (CZ)
  • New Technologies—Research Centre, University of West Bohemia, 301 00 Plzeň, Czech Republic
Corresponding author
Švantner, Michal
Venue
The 16th International Workshop on Advanced Infrared Technology & Applications
Publisher
MDPI
Published
2021-11-17
Pages
4
OpenAlex
W3212153468
Cited by
5
References
8
Citations by year
2024: 1 · 2023: 1 · 2022: 3
FWCI
1.57
Type
conference paper
Language
en
Open access
Locations
International Workshop on Advanced Infrared Technology and Applications (AITA) (publishedVersion, cc-by)
Funders
European Regional Development Fund (02.1.01/0.0/0.0, CZ.02.1.01/0.0/0.0/18_069/0010018, CZ.02, CZ.02.1.01, CZ.02.1.01/0.0, CZ.02.1.01/0.0/0.0)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
Keywords
infrared thermography, body temperature measurement, measurement accuracy, non-contact temperature measurement, measurement reliability, ambient temperature dependence, temperature change, infectious disease screening

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review