Indoor Air Quality: A Review of Cleaning Technologies
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Aims: Indoor air quality (IAQ) has attracted increased attention with the emergence of COVID-19. Ventilation is perhaps the area in which the most changes have been proposed in response to the emergency caused by this virus. However, other strategies are possible, such as source control and the extraction of pollutants. The latter incorporates clean technologies, an emergent area with respect to IAQ. Method: Various air treatment technologies can be used to control contaminants, which are reviewed and discussed in this work, including physicochemical technologies (e.g., filtration, adsorption, UV-photocatalytic oxidation, ultraviolet disinfection and ionization) and biological technologies (e.g., plant purification methods and microalgae-based methods). Results and interpretation: This work reviews currently available solutions and technologies for “cleaning” indoor air, with a focus on their advantages and disadvantages. One of the most common problems in this area is the emission of pollutants that are sometimes more dangerous to human health than those that the technologies were developed to remove. Another aspect to consider is the limitation of each technology in relation to the type of pollutants that need to be removed. Each of the investigated technologies works well for a family of pollutants with similar characteristics, but it is not applicable to all pollutant types. Thus, the optimal solution may involve the use of a combination of technologies to extend the scope of application, in addition to the development of new materials, for example, through the use of nanotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microalgae for biodiesel production and other applications: A review
Mata, T. M., Martins, A. A., & Caetano, N. S. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.07.020 · Cited by 5,685 · cited 2×
“, biohydrogen, biodiesel, bioethanol, biobutanol, biomethanol and other biohydrocarbons), thus generating environmental and economic value [151,154] (Figure 5).”
BackgroundSelf-citationOn the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613
A Review: Microalgae and Their Applications in CO2 Capture and Renewable Energy
Klinthong, W., Yang, Y.-H., Huang, C.-H., & Tan, C.-S. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2014.11.0299 · Cited by 278
Blocken, B., van Druenen, T., Ricci, A., Kang, L., van Hooff, T., Qin, P., Xia, L., Ruiz, C. A., Arts, J. H., Diepens, J. F. L., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107659 · Cited by 183 · cited 1×
“[45] assessed aerosol levels in a gymnasium, and demonstrated that the existing mechanical ventilation systems alone are not efficient to decrease the levels.”
BackgroundPearlmutter, D., Theochari, D., Nehls, T., Pinho, P., Piro, P., Korolova, A., Papaefthimiou, S., Mateo, M. C. G., Calheiros, C., Zluwa, I., et al. (2020) · Blue-Green Systems · doi:10.2166/bgs.2019.928 · Cited by 176
Self-citationLevels and sources of volatile organic compounds in homes of children with asthma
Chin, J.-Y., Godwin, C., Parker, E., Robins, T., Lewis, T., Harbin, P., & Batterman, S. (2014) · Indoor Air · doi:10.1111/ina.12086 · Cited by 165
Nature-based solutions as tools for air phytoremediation: A review of the current knowledge and gaps
Prigioniero, A., Zuzolo, D., Niinemets, Ü., & Guarino, C. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.116817 · Cited by 51 · cited 6×
“In general terms, active vegetation systems (in combination with mechanical systems) and passive vegetation systems (without additional energy requirements) can be considered for the present purpose [130,133].”
BackgroundInfluential
Research works printed but not linked: 133
- Mannan, M., and Al-Ghamdi, S. (2021). Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure. Int. J. Environ. Res. Public Health, 18. · DOI · Paper page
- Jones, 1999, Indoor air quality and health, Atmos. Environ., 33, 4535, 10.1016/S1352-2310(99)00272-1 · DOI · Paper page
- Van Tran, V., Park, D., and Lee, Y.-C. (2020). Indoor Air Pollution, Related Human Diseases, and Recent Trends in the Control and Improvement of Indoor Air Quality. Int. J. Environ. Res. Public Health, 17. · DOI · Paper page
- Mata, T.M., Oliveira, G.M., Monteiro, H., Silva, G.V., Caetano, N.S., and Martins, A.A. (2021). Indoor Air Quality Improvement Using Nature-Based Solutions: Design Proposals to Greener Cities. Int. J. Environ. Res. Public Health, 18. · DOI
- Mata, T.M., Felgueiras, F., Martins, A.A., Monteiro, H., Ferraz, M.P., Oliveira, G.M., Gabriel, M.F., and Silva, G.V. (2022). Indoor Air Quality in Elderly Centers: Pollutants Emission and Health Effects. Environments, 9. · DOI
- Kelly, 2018, Improving indoor air quality, health and performance within environments where people live, travel, learn and work, Atmos. Environ., 200, 90, 10.1016/j.atmosenv.2018.11.058 · DOI · Paper page
- Kraakman, 2021, A state–of–the–art review on indoor air pollution and strategies for indoor air pollution control, Chemosphere, 262, 128376, 10.1016/j.chemosphere.2020.128376 · DOI · Paper page
- Yocom, 1982, A Critical Review, J. Air Pollut. Control. Assoc., 32, 500, 10.1080/00022470.1982.10465427 · doi:10.1080/00022470.1982.10465427
- Zhang, 2016, Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self-assessed acute health symptoms, and cognitive performance, Indoor Air, 27, 47, 10.1111/ina.12284 · DOI · Paper page
- Permentier, 2017, Carbon dioxide poisoning: A literature review of an often forgotten cause of intoxication in the emergency department, Int. J. Emerg. Med., 10, 14, 10.1186/s12245-017-0142-y · doi:10.1186/s12245-017-0142-y
- Sokhi, 2022, Advances in air quality research–current and emerging challenges, Atmos. Chem. Phys., 22, 4615, 10.5194/acp-22-4615-2022 · DOI · Paper page
- Hassanvand, 2015, Characterization of PAHs and metals in indoor/outdoor PM10/PM2.5/PM1 in a retirement home and a school dormitory, Sci. Total Environ., 527–528, 100, 10.1016/j.scitotenv.2015.05.001 · DOI · Paper page
- Luengas, 2015, A review of indoor air treatment technologies, Rev. Environ. Sci. Bio. Technol., 14, 499, 10.1007/s11157-015-9363-9 · DOI · Paper page
- Silva, G.V., Martins, A.O., and Martins, S.D.S. (2021). Indoor Air Quality: Assessment of Dangerous Substances in Incense Products. Int. J. Environ. Res. Public Health, 18. · DOI
- Kim, 2017, Air ionization as a control technology for off-gas emissions of volatile organic compounds, Environ. Pollut., 225, 729, 10.1016/j.envpol.2017.03.026 · doi:10.1016/j.envpol.2017.03.026
- Wang, 2011, Characterization and performance evaluation of a full-scale activated carbon-based dynamic botanical air filtration system for improving indoor air quality, Build. Environ., 46, 758, 10.1016/j.buildenv.2010.10.008 · DOI
- Pacheco-Torgal, F., Labrincha, J.A., Diamanti, M.V., Yu, C.P., and Lee, H.K. (2015). Biotechnologies and Biomimetics for Civil Engineering, Springer International Publishing Switzerland. · DOI
- Daugulis, 2012, Recent advances in two-phase partitioning bioreactors for the treatment of volatile organic compounds, Biotechnol. Adv., 30, 1707, 10.1016/j.biotechadv.2012.08.009 · DOI · Paper page
- Salama, 2022, Purification of Ambient Air by Novel Green Plant with Titanium Dioxide Nanoparticles, Int. J. Prev. Med., 13, 67, 10.4103/ijpvm.IJPVM_586_20 · DOI
- Szczotko, M., Orych, I., Mąka, L., and Solecka, J. (2022). A Review of Selected Types of Indoor Air Purifiers in Terms of Microbial Air Contamination Reduction. Atmosphere, 13. · DOI
- Miller, 1996, Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control, J. Air Waste Manag. Assoc., 46, 869, 10.1080/10473289.1996.10467523 · DOI
- Nazarenko, 2020, Air Filtration and Severe Acute Respiratory Syndrome Coronavirus 2, Epidemiol. Health, 42, e2020049, 10.4178/epih.e2020049 · DOI
- Liu, 2017, A review of air filtration technologies for sustainable and healthy building ventilation, Sustain. Cities Soc., 32, 375, 10.1016/j.scs.2017.04.011 · DOI
- Bluyssen, 2020, The effect of a mobile HEPA filter system on ‘infectious’ aerosols, sound and air velocity in the SenseLab, Build. Environ., 188, 107475, 10.1016/j.buildenv.2020.107475 · DOI
- Villanueva, 2021, Sampling and analysis techniques for inorganic air pollutants in indoor air, Appl. Spectrosc. Rev., 57, 531, 10.1080/05704928.2021.2020807 · doi:10.1080/05704928.2021.2020807
- Zhao, 2020, Air purifiers: A supplementary measure to remove airborne SARS-CoV-2, Build. Environ., 177, 106918, 10.1016/j.buildenv.2020.106918 · DOI
- Liu, 2021, Portable HEPA Purifiers to Eliminate Airborne SARS-CoV-2: A Systematic Review, Otolaryngol. Neck Surg., 166, 615, 10.1177/01945998211022636 · DOI
- Minguillón, M.C., Querol, X., Alastuey, A., Riediker, M., Felisi, J.M., Garrido, T., Bekö, G., Nehr, S., Wiesen, P., and Carslaw, N. (2022, July 02). Guide for Ventilation towards Healthy Classrooms. COST Action CA17136 Report. Available online: http://hdl.handle.net/10261/225519.
- Cox, 2018, Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways, Indoor Air, 28, 818, 10.1111/ina.12502 · DOI
- Dubey, 2021, Assessing effectiveness of air purifiers (HEPA) for controlling indoor particulate pollution, Heliyon, 7, e07976, 10.1016/j.heliyon.2021.e07976 · DOI
- Lee, 2021, Effectiveness of portable air filtration on reducing indoor aerosol transmission: Preclinical observational trials, J. Hosp. Infect., 119, 163, 10.1016/j.jhin.2021.09.012 · DOI
- Cheek, 2020, Portable air purification: Review of impacts on indoor air quality and health, Sci. Total Environ., 766, 142585, 10.1016/j.scitotenv.2020.142585 · DOI · Paper page
- Bahri, 2013, Plasma-Based Indoor Air Cleaning Technologies: The State of the Art-Review, CLEAN Soil Air Water, 42, 1667, 10.1002/clen.201300296 · DOI
- Swamy, 2021, Development of an indoor air purification system to improve ventilation and air quality, Heliyon, 7, e08153, 10.1016/j.heliyon.2021.e08153 · DOI
- Martins, 2022, Air pollution control for indoor environments using nanofiber filters: A brief review and post-pandemic perspectives, Chem. Eng. J. Adv., 11, 100330, 10.1016/j.ceja.2022.100330 · DOI
- Aydin, 2020, Design and fabrication of nano-engineered electrospun filter media with cellulose nanocrystal for toluene adsorption from indoor air, Mater. Sci. Eng. B, 264, 114953
- Kadam, 2020, Gelatin/β–Cyclodextrin Bio–Nanofibers as respiratory filter media for filtration of aerosols and volatile organic compounds at low air resistance, J. Hazard. Mater., 403, 123841, 10.1016/j.jhazmat.2020.123841 · DOI
- Niu, 2020, Indoor air filtration could lead to increased airborne endotoxin levels, Environ. Int., 142, 105878, 10.1016/j.envint.2020.105878 · DOI
- Bliss, S. (2005). Best Practices Guide to Residential Construction: Materials, Finishes, and Details, Wiley.
- Liu, 2020, Metabolic linkages between indoor negative air ions, particulate matter and cardiorespiratory function: A randomized, double-blind crossover study among children, Environ. Int., 138, 105663, 10.1016/j.envint.2020.105663 · DOI
- Guieysse, 2008, Biological treatment of indoor air for VOC removal: Potential and challenges, Biotechnol. Adv., 26, 398, 10.1016/j.biotechadv.2008.03.005 · DOI · Paper page
- Waring, 2010, The effect of an ion generator on indoor air quality in a residential room, Indoor Air, 21, 267, 10.1111/j.1600-0668.2010.00696.x · DOI
- Anirudhan, 2011, Adsorptive removal of heavy metal ions from industrial effluents using activated carbon derived from waste coconut buttons, J. Environ. Sci., 23, 1989, 10.1016/S1001-0742(10)60515-3 · DOI · Paper page
- Xie, 2018, Indoor air pollution and control technology, IOP Conf. Ser. Earth Environ. Sci., 170, 032084, 10.1088/1755-1315/170/3/032084 · doi:10.1088/1755-1315/170/3/032084
- Gall, 2011, Barriers and opportunities for passive removal of indoor ozone, Atmos. Environ., 45, 3338, 10.1016/j.atmosenv.2011.03.032 · DOI
- Jo, 2009, Granular-activated carbon adsorption followed by annular-type photocatalytic system for control of indoor aromatic compounds, Sep. Purif. Technol., 66, 438, 10.1016/j.seppur.2009.02.014 · DOI
- Ao, 2004, Combination effect of activated carbon with TiO2 for the photodegradation of binary pollutants at typical indoor air level, J. Photochem. Photobiol. A Chem., 161, 131, 10.1016/S1010-6030(03)00276-4 · DOI · Paper page
- Ao, 2005, Indoor air purification by photocatalyst TiO2 immobilized on an activated carbon filter installed in an air cleaner, Chem. Eng. Sci., 60, 103, 10.1016/j.ces.2004.01.073 · DOI · Paper page
- Sidheswaran, 2012, Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters, Build. Environ., 47, 357, 10.1016/j.buildenv.2011.07.002 · doi:10.1016/j.buildenv.2011.07.002
- Cheng, 2012, Antibacterial and Regenerated Characteristics of Ag-zeolite for Removing Bioaerosols in Indoor Environment, Aerosol Air Qual. Res., 12, 409, 10.4209/aaqr.2011.08.0134 · doi:10.4209/aaqr.2011.08.0134
- Stefanowski, 2017, Improvement of indoor air quality by MDF panels containing walnut shells, Build. Environ., 123, 427, 10.1016/j.buildenv.2017.07.015 · DOI
- Cao, J.-J., Huang, Y., and Zhang, Q. (2021). Ambient Air Purification by Nanotechnologies: From Theory to Application. Catalysts, 11. · DOI
- Hodgson, 2007, Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications, Indoor Air, 17, 305, 10.1111/j.1600-0668.2007.00479.x · DOI · Paper page
- Geiss, 2012, Photocatalytic degradation of organic paint constituents-formation of carbonyls, Build. Environ., 48, 107, 10.1016/j.buildenv.2011.08.021 · DOI
- Farhanian, 2014, Photocatalytic oxidation air cleaner: Identification and quantification of by-products, Build. Environ., 72, 34, 10.1016/j.buildenv.2013.10.014 · doi:10.1016/j.buildenv.2013.10.014
- Kaushik, 2022, Photoelectrochemical oxidation assisted air purifiers; perspective as potential tools to control indoor SARS-CoV-2 Exposure, Appl. Surf. Sci. Adv., 9, 100236, 10.1016/j.apsadv.2022.100236 · DOI
- Cansoy, 2022, Fabrication and characterization of multifunctional nanoclay and TiO2 embedded polyamide electrospun nanofibers and their applications at indoor air filtration, Mater. Sci. Eng. B, 279, 115675, 10.1016/j.mseb.2022.115675 · doi:10.1016/j.mseb.2022.115675
- Weon, 2018, Active {001} Facet Exposed TiO2 Nanotubes Photocatalyst Filter for Volatile Organic Compounds Removal: From Material Development to Commercial Indoor Air Cleaner Application, Environ. Sci. Technol., 52, 9330, 10.1021/acs.est.8b02282 · DOI · Paper page
- Wang, 2022, A review on heterogeneous photocatalysis for environmental remediation: From semiconductors to modification strategies, Chin. J. Catal., 43, 178, 10.1016/S1872-2067(21)63910-4 · DOI · Paper page
- Ren, 2017, Photocatalytic materials and technologies for air purification, J. Hazard. Mater., 325, 340, 10.1016/j.jhazmat.2016.08.072 · DOI · Paper page
- Monteiro, 2015, Photocatalytic oxidation of gaseous perchloroethylene over TiO 2 based paint, J. Photochem. Photobiol. A Chem., 311, 41, 10.1016/j.jphotochem.2015.06.007 · DOI
- Maggos, T., Binas, V., Siaperas, V., Terzopoulos, A., Panagopoulos, P., and Kiriakidis, G. (2019). A Promising Technological Approach to Improve Indoor Air Quality. Appl. Sci., 9. · DOI
- Salvadores, 2020, Kinetic study of air treatment by photocatalytic paints under indoor radiation source: Influence of ambient conditions and photocatalyst content, Appl. Catal. B Environ., 268, 118694, 10.1016/j.apcatb.2020.118694 · doi:10.1016/j.apcatb.2020.118694
- Demeestere, 2008, Heterogeneous photocatalytic removal of toluene from air on building materials enriched with TiO2, Build. Environ., 43, 406, 10.1016/j.buildenv.2007.01.016 · DOI · Paper page
- Ichiura, 2002, Removal of indoor pollutants under UV irradiation by a composite TiO2–zeolite sheet prepared using a papermaking technique, Chemosphere, 50, 79, 10.1016/S0045-6535(02)00604-5 · DOI
- Dong, 2006, Decomposition of indoor ammonia with TiO2-loaded cotton woven fabrics prepared by different textile finishing methods, Atmos. Environ., 41, 3182, 10.1016/j.atmosenv.2006.08.056 · doi:10.1016/j.atmosenv.2006.08.056
- Zuraimi, 2018, Performance of sorption- and photocatalytic oxidation-based indoor passive panel technologies, Build. Environ., 135, 85, 10.1016/j.buildenv.2018.03.004 · DOI
- Shayegan, 2022, A review on an emerging solution to improve indoor air quality: Application of passive removal materials, Build. Environ., 219, 109228, 10.1016/j.buildenv.2022.109228 · DOI
- Kowalski, W. (2009). Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection, Springer. · DOI · Paper page
- Rauth, 1965, The Physical State of Viral Nucleic Acid and the Sensitivity of Viruses to Ultraviolet Light, Biophys. J., 5, 257, 10.1016/S0006-3495(65)86715-7 · DOI · Paper page
- Whyte, 1968, Bacteriological aspects of air-conditioning plants, Epidemiol. Infect., 66, 567, 10.1017/S002217240002831X · doi:10.1017/s002217240002831x
- Cooley, 1998, Correlation between the prevalence of certain fungi and sick building syndrome, Occup. Environ. Med., 55, 579, 10.1136/oem.55.9.579 · DOI · Paper page
- Lee, 2021, Evaluation of multiple fixed in-room air cleaners with ultraviolet germicidal irradiation, in high-occupancy areas of selected commercial indoor environments, J. Occup. Environ. Hyg., 19, 67, 10.1080/15459624.2021.1991581 · DOI
- Menzies, 2003, Effect of ultraviolet germicidal lights installed in office ventilation systems on workers’ health and wellbeing: Double-blind multiple crossover trial, Lancet, 362, 1785, 10.1016/S0140-6736(03)14897-0 · DOI
- 2012, Germicidal ultraviolet light and environmental control of microorganisms in hospitals, Rev. Costarric. Salud Pública, 21, 19
- Esteves, S., Varghese, A.C., and Worrilow, K.C. (2017). Air disinfection for ART clinics using ultraviolet germicidal irradiation—Chapter 10. Clean Room Technology in ART Clinics, CRC Press, Taylor & Francis Group. · doi:10.1201/9781315372464
- Cardoso, 2021, Effectiveness of a UVC air disinfection system for the HVAC of an ICU, Eur. Phys. J. Plus, 137, 37
- Kramer, 2017, Improving Indoor Air Quality through the Use of Ultraviolet Technology in Commercial Buildings, Procedia Eng., 196, 888, 10.1016/j.proeng.2017.08.021 · DOI
- Hart, D. (1937). Sterilization of the Air in the Operating Room by Bactericidal Radiant Energy, American Association for Thoracic Surgery. · doi:10.1378/chest.3.6.14
- Armellino, 2019, Comparative evaluation of operating room terminal cleaning by two methods: Focused multivector ultraviolet (FMUV) versus manual-chemical disinfection, Am. J. Infect. Control., 48, 147, 10.1016/j.ajic.2019.10.009 · DOI
- ASHRAE (2019). Ultraviolet air and surface treatment—Chapter 62. ASHRAE Handbook, HVAC Applications, SI Edition, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
- Levetin, 2001, Effectiveness of Germicidal UV Radiation for Reducing Fungal Contamination within Air-Handling Units, Appl. Environ. Microbiol., 67, 3712, 10.1128/AEM.67.8.3712-3715.2001 · doi:10.1128/aem.67.8.3712-3715.2001
- Brickner, 2003, The application of ultraviolet germicidal irradiation to control transmission of airborne disease: Bioterrorism countermeasure, Public Health Rep., 118, 99, 10.1016/S0033-3549(04)50225-X · DOI
- Kujundzic, 2007, Ultraviolet germicidal irradiation inactivation of airborne fungal spores and bacteria in upper-room air and HVAC in-duct configurations, J. Environ. Eng. Sci., 6, 1, 10.1139/s06-039 · DOI
- Zhang, 2020, Disinfection by in-duct ultraviolet lamps under different environmental conditions in turbulent airflows, Indoor Air, 30, 500, 10.1111/ina.12642 · DOI
- Yang, 2018, Disinfection efficacy of ultraviolet germicidal irradiation on airborne bacteria in ventilation ducts, Indoor Air, 28, 806, 10.1111/ina.12504 · DOI
- Escombe, A.R., Moore, D.A.J., Gilman, R.H., Ñavincopa, M., Ticona, E., Mitchell, B., Noakes, C., Martínez, C., Sheen, P., and Ramirez, R. (2009). Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis Transmission. PLoS Med., 6. · DOI · Paper page
- Luongo, 2017, Ultraviolet germicidal coil cleaning: Impact on heat transfer effectiveness and static pressure drop, Build. Environ., 112, 159, 10.1016/j.buildenv.2016.11.022 · DOI
- Nardell, 2021, Air Disinfection for Airborne Infection Control with a Focus on COVID-19: Why Germicidal UV is Essential, Photochem. Photobiol., 97, 493, 10.1111/php.13421 · DOI
- Harstad, 1954, Use of Ultraviolet Irradiation in a Room Air Conditioner for Removal of Bacteria, Appl. Microbiol., 2, 148, 10.1128/am.2.3.148-151.1954 · doi:10.1128/am.2.3.148-151.1954
- Bedford, 1927, The Nature of the Action of Ultra-Violet Light on Micro-Organisms, Br. J. Exp. Pathol., 8, 437
- Gates, 1929, A study of the bactericidal action of ultra violet light: I. The Reaction to Monochromatic Radiations, J. Gen. Physiol., 13, 231, 10.1085/jgp.13.2.231 · DOI
- Gates, 1930, A study of the bactericidal action of ultra violet light: III. The Absorption of Ultra Violet Light by Bacteria, J. Gen. Physiol., 14, 31, 10.1085/jgp.14.1.31 · DOI · Paper page
- Fulton, 1929, The fungicidal action of the ultraviolet, J. Agric. Res., 38, 159
- Rivers, 1928, Ultra-violet light and vaccine virus, J. Exp. Med., 47, 45, 10.1084/jem.47.1.45 · doi:10.1084/jem.47.1.45
- Chang, 2012, Effects of Ultraviolet Germicidal Irradiation and Swirling Motion on Airborne Staphylococcus aureus, Pseudomonas aeruginosa and Legionella pneumophila under Various Relative Humidities, Indoor Air, 23, 74, 10.1111/j.1600-0668.2012.00793.x · DOI
- Nguyen, T.T., Johnson, G.R., Bell, S.C., and Knibbs, L.D. (2022). A Systematic Literature Review of Indoor Air Disinfection Techniques for Airborne Bacterial Respiratory Pathogens. Int. J. Environ. Res. Public Health, 19. · DOI
- Schurk, 2021, A Bipolar Ionization Primer for HVAC Professionals, ASHRAE J., 63, 40
- Meschke, 2009, The effect of surface charge, negative and bipolar ionization on the deposition of airborne bacteria, J. Appl. Microbiol., 106, 1133, 10.1111/j.1365-2672.2008.04078.x · DOI
- Kanesaka, 2022, Evaluation of a bipolar ionization device in inactivation of antimicrobial-resistant bacteria, yeast, Aspergillus spp. and human coronavirus, J. Hosp. Infect., 126, 16, 10.1016/j.jhin.2022.04.004 · DOI
- Hyun, 2017, Application of corona discharge-generated air ions for filtration of aerosolized virus and inactivation of filtered virus, J. Aerosol Sci., 107, 31, 10.1016/j.jaerosci.2017.02.004 · DOI
- Pushpawela, 2017, Efficiency of ionizers in removing airborne particles in indoor environments, J. Electrost., 90, 79, 10.1016/j.elstat.2017.10.002 · doi:10.1016/j.elstat.2017.10.002
- Zhou, 2016, Inactivation of airborne bacteria by cold plasma in air duct flow, Build. Environ., 106, 120, 10.1016/j.buildenv.2016.06.026 · DOI
- Zeng, 2021, Evaluating a commercially available in-duct bipolar ionization device for pollutant removal and potential byproduct formation, Build. Environ., 195, 107750, 10.1016/j.buildenv.2021.107750 · DOI
- Moya, 2019, A review of green systems within the indoor environment, Indoor Built Environ., 28, 298, 10.1177/1420326X18783042 · DOI · Paper page
- Deng, 2018, The basic roles of indoor plants in human health and comfort, Environ. Sci. Pollut. Res., 25, 36087, 10.1007/s11356-018-3554-1 · DOI · Paper page
- Han, 2021, Plant-based remediation of air pollution: A review, J. Environ. Manag., 301, 113860, 10.1016/j.jenvman.2021.113860 · DOI
- Hassan, 2021, The Role of Indoor Plants in air Purification and Human Health in the Context of COVID-19 Pandemic: A Proposal for a Novel Line of Inquiry, Front. Mol. Biosci., 8, 709395, 10.3389/fmolb.2021.709395 · DOI
- Megahed, 2020, Indoor Air Quality: Rethinking rules of building design strategies in post-pandemic architecture, Environ. Res., 193, 110471, 10.1016/j.envres.2020.110471 · DOI · Paper page
- Irga, 2018, The phytoremediation of indoor air pollution: A review on the technology development from the potted plant through to functional green wall biofilters, Rev. Environ. Sci. Bio. Technol., 17, 395, 10.1007/s11157-018-9465-2 · DOI
- Gawronski, 2017, Plants in Air Phytoremediation, Adv. Bot. Res., 83, 319, 10.1016/bs.abr.2016.12.008 · DOI
- Teiri, 2021, A review of different phytoremediation methods and critical factors for purification of common indoor air pollutants: An approach with sensitive analysis, Air Qual. Atmos. Health, 15, 373, 10.1007/s11869-021-01118-3 · DOI
- Soreanu, 2013, Botanical Biofiltration of Indoor Gaseous Pollutants—A Mini-Review, Chem. Eng. J., 229, 585, 10.1016/j.cej.2013.06.074 · DOI · Paper page
- Wang, 2014, Effect of ecosystem services provided by urban green infrastructure on indoor environment: A literature review, Build. Environ., 77, 88, 10.1016/j.buildenv.2014.03.021 · DOI · Paper page
- Yang, 2009, Volatile Organic Compounds Emanating from Indoor Ornamental Plants, HortScience, 44, 396, 10.21273/HORTSCI.44.2.396 · doi:10.21273/hortsci.44.2.396
- Gubb, 2022, Potted plants can remove the pollutant nitrogen dioxide indoors, Air Qual. Atmos. Health, 15, 479, 10.1007/s11869-022-01171-6 · DOI
- Jung, C., and Awad, J. (2021). Improving the IAQ for Learning Efficiency with Indoor Plants in University Classrooms in Ajman, United Arab Emirates. Buildings, 11. · DOI
- Christensen, 2014, Can ornamental potted plants remove volatile organic compounds from indoor air?—A review, Environ. Sci. Pollut. Res., 21, 13909, 10.1007/s11356-014-3240-x · DOI · Paper page
- Peng, 2019, Investigation of Indoor Air Quality and Identification of Plant’s Capabilities in Removing Air Pollutants in Urban Residential Buildings, IOP Conf. Ser. Earth Environ. Sci., 281, 012018, 10.1088/1755-1315/281/1/012018 · DOI
- Auer, T., Radi, M., and Brkovi, M. (2019). Green Facades and Living Walls—A Review Establishing the Classification of Construction Types and Mapping the Benefits. Sustainability, 11. · DOI · Paper page
- Francis, 2011, Urban reconciliation ecology: The potential of living roofs and walls, J. Environ. Manag., 92, 1429, 10.1016/j.jenvman.2011.01.012 · DOI · Paper page
- Gattringer, 2021, Nature based solution for indoor air quality treatment, J. Phys. Conf. Ser., 2042, 012133, 10.1088/1742-6596/2042/1/012133 · doi:10.1088/1742-6596/2042/1/012133
- Thomas, 2015, Phytoremediation of Indoor Air, HortScience, 50, 765, 10.21273/HORTSCI.50.5.765 · DOI
- Junior, 2020, Microalgae for biotechnological applications: Cultivation, harvesting and biomass processing, Aquaculture, 528, 735562, 10.1016/j.aquaculture.2020.735562 · DOI · Paper page
- Corrêa, P.S., Júnior, W.G.M., Martins, A.A., Caetano, N.S., and Mata, T.M. (2020). Microalgae Biomolecules: Extraction, Separation and Purification Methods. Processes, 9. · DOI · Paper page
- Branco-Vieira, M., Martin, S.S., Agurto, C., dos Santos, M.A., Freitas, M.A.V., Mata, T.M., Martins, A.A., and Caetano, N.S. (2017). Potential of Phaeodactylum tricornutum for Biodiesel Production under Natural Conditions in Chile. Energies, 11. · DOI · Paper page
- Chew, 2020, Algae utilization and its role in the development of green cities, Chemosphere, 268, 129322, 10.1016/j.chemosphere.2020.129322 · DOI
- European Commission (2021, February 09). Directorate General for the Environment. Building a Green Infrastructure for Europe. Available online: https://data.europa.eu/doi/10.2779/54125. · doi:10.2779/54125
- Elrayies, 2018, Microalgae: Prospects for greener future buildings. Renew. Sustain, Energy Rev., 81, 1175
- Barati, 2022, Microalgae as a Natural CO2 Sequester: A Study on Effect of Tobacco Smoke on Two Microalgae Biochemical Responses, Front. Energy Res., 10, 881758, 10.3389/fenrg.2022.881758 · DOI
- Yewale, 2022, Studies on Biosmotrap: A multipurpose biological air purifier to minimize indoor and outdoor air pollution, J. Clean. Prod., 357, 132001, 10.1016/j.jclepro.2022.132001 · DOI
- Lu, 2018, Application of a novel microalgae-film based air purifier to improve air quality through oxygen production and fine particulates removal, J. Chem. Technol. Biotechnol., 94, 1057, 10.1002/jctb.5852 · DOI · Paper page
- Thawechai, 2016, Mitigation of carbon dioxide by oleaginous microalgae for lipids and pigments production: Effect of light illumination and carbon dioxide feeding strategies, Bioresour. Technol., 219, 139, 10.1016/j.biortech.2016.07.109 · DOI
Cited by
Han, M., Park, J., Kim, I., & Yi, H. (2023) · Applied Sciences · doi:10.3390/app132412991 · Cited by 11
Metadata
- Authors
- Mata, T. M., Martins, A. A., Calheiros, C. S. C., Villanueva, F., Alonso-Cuevilla, N. P., Gabriel, M. F., & Silva, G. V.
- Venue
- Environments
- Publisher
- MDPI AG
- Published
- 2022-09-07
- Volume
- 9
- Issue
- 9
- Pages
- 118
- ISSN
- 2076-3298 (ISSN-L)
- OpenAlex
- W4297028327
- Cited by
- 176
- References
- 7
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- ALiCE (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- LEPABE (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- LAETA (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- FCT/MCTES (PIDDAC) (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- Portuguese National Funding Agency for Science, Research, and Technology (FCT) (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- Programa Operacional Regional do Norte (NORTE2020) (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
- FCT—Fundação para Ciência e Tecnologia (LA/P/0045/2020, UIDB/00511/2020, UIDB/50022/2020, DL 57/2016, NORTE-06-3559-FSE-000107, UIDB/04423/2020, UIDP/04423/2020)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor Air Quality: A Review of Cleaning Technologies. https://app.cochat.ai/papers/10.3390/environments9090118
- The paper
- Mata, T. M., Martins, A. A., Calheiros, C. S. C., Villanueva, F., Alonso-Cuevilla, N. P., Gabriel, M. F., & Silva, G. V. (2022). Indoor Air Quality: A Review of Cleaning Technologies. Environments. https://doi.org/10.3390/environments9090118
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.