Detection of COVID-19 Patients from CT Scan and Chest X-ray Data Using Modified MobileNetV2 and LIME
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The COVID-19 global pandemic caused by the widespread transmission of the novel coronavirus (SARS-CoV-2) has become one of modern history’s most challenging issues from a healthcare perspective. At its dawn, still without a vaccine, contagion containment strategies remained most effective in preventing the disease’s spread. Patient isolation has been primarily driven by the results of polymerase chain reaction (PCR) testing, but its initial reach was challenged by low availability and high cost, especially in developing countries. As a means of taking advantage of a preexisting infrastructure for respiratory disease diagnosis, researchers have proposed COVID-19 patient screening based on the results of Chest Computerized Tomography (CT) and Chest Radiographs (X-ray). When paired with artificial-intelligence- and deep-learning-based approaches for analysis, early studies have achieved a comparatively high accuracy in diagnosing the disease. Considering the opportunity to further explore these methods, we implement six different Deep Convolutional Neural Networks (Deep CNN) models—VGG16, MobileNetV2, InceptionResNetV2, ResNet50, ResNet101, and VGG19—and use a mixed dataset of CT and X-ray images to classify COVID-19 patients. Preliminary results showed that a modified MobileNetV2 model performs best with an accuracy of 95 ± 1.12% (AUC = 0.816). Notably, a high performance was also observed for the VGG16 model, outperforming several previously proposed models with an accuracy of 98.5 ± 1.19% on the X-ray dataset. Our findings are supported by recent works in the academic literature, which also uphold the higher performance of MobileNetV2 when X-ray, CT, and their mixed datasets are considered. Lastly, we further explain the process of feature extraction using Local Interpretable Model-Agnostic Explanations (LIME), which contributes to a better understanding of what features in CT/X-ray images characterize the onset of COVID-19.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Inception-v4, Inception-ResNet and the Impact of Residual Connections on Learning
Szegedy, C., Ioffe, S., Vanhoucke, V., & Alemi, A. (2017) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v31i1.11231 · Cited by 4,636 · cited 3×
“We used six different pre-trained ConvNets: VGG16, MobileNetV2, ResNet50, ResNet101, InceptionResNetV2, and VGG19.”
MethodInfluentialThe Effectiveness of Data Augmentation in Image Classification using Deep Learning
Perez, L., & Wang, J. (2017) · arXiv · doi:10.48550/arxiv.1712.04621 · Cited by 2,499 · cited 1×
“Adaptive learning rate optimization, also known as Adam [28,29], was used as an optimization algorithm as used in previous works [14].”
MethodApostolopoulos, I. D., & Mpesiana, T. A. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00865-4 · Cited by 2,338 · cited 1×
“On that note, Apostol, Oztuk, and Khan (2020) considered an imbalanced dataset of 284 COVID-19 and 967 non-COVID-19 patient chest X-ray images and achieved 89.6% accuracy using a CNN-based Xception model [17].”
BackgroundInfluentialNarin, A., Kaya, C., & Pamuk, Z. (2021) · Pattern Analysis and Applications · doi:10.1007/s10044-021-00984-y · Cited by 2,054 · cited 2×
“In parallel, several studies explored and recommended screening COVID-19 patients using chest X-ray images instead—notable contributions can be found in [11–13].”
BackgroundMethodLi, L., Qin, L., Xu, Z., Yin, Y., Wang, X., Kong, B., Bai, J., Lu, Y., Fang, Z., Song, Q., et al. (2020) · Radiology · doi:10.1148/radiol.2020200905 · Cited by 1,927 · cited 1×
“These results outperform the referenced literature [34,35], which used large datasets containing 4356 and 1065 images, respectively.”
ResultSmith, L. N. (2018) · arXiv · doi:10.48550/arxiv.1803.09820 · Cited by 790 · cited 2×
“At first, the following were chosen at random: Batch size = [20, 30, 40, 50, 60]; Number of epochs = [20, 25, 30, 35, 40]; Learning rate = [0.001, 0.01, 0.1].”
BackgroundMethodInfluentialExplainable Deep Learning for Pulmonary Disease and Coronavirus COVID-19 Detection from X-rays
Brunese, L., Mercaldo, F., Reginelli, A., & Santone, A. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105608 · Cited by 623 · cited 2×
“Researchers often train their models with large chest X-ray image datasets [15,16] in order to develop a robust model.”
BackgroundMethodInfluential
Cited by
Machine-learning-based disease diagnosis: a comprehensive review
Ahsan, M. M., Luna, S. A., & Siddique, Z. (2022) · Healthcare · doi:10.3390/healthcare10030541 · Cited by 603
“Despite the fact that a vaccine had been advanced in distribution because to the global emergency, it was unavailable to the majority of people for the duration of the crisis [88].”
BackgroundSelf-citationŞAHiN, E., Arslan, N. N., & Özdemir, D. (2025) · Neural Computing and Applications · doi:10.1007/s00521-024-10437-2 · Cited by 278
Bhandari, M., Shahi, T. B., Siku, B., & Neupane, A. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106156 · Cited by 193
Explainable artificial intelligence (XAI) in radiology and nuclear medicine: a literature review
de Vries, B. M., Zwezerijnen, G. J. C., Burchell, G. L., van Velden, F. H. P., Menke-van der Houven van Oordt, C. W., & Boellaard, R. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1180773 · Cited by 106
Sakai, A., Komatsu, M., Komatsu, R., Matsuoka, R., Yasutomi, S., Dozen, A., Shozu, K., Arakaki, T., Machino, H., Asada, K., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10030551 · Cited by 68
Metadata
- Authors
- Ahsan, M. M., Nazim, R., Siddique, Z., & Huebner, P.
- Venue
- Healthcare
- Publisher
- MDPI AG
- Published
- 2021-08-25
- Volume
- 9
- Issue
- 9
- Pages
- 1099
- ISSN
- 2227-9032 (ISSN-L)
- OpenAlex
- W3194248593
- Cited by
- 95
- References
- 8
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of COVID-19 Patients from CT Scan and Chest X-ray Data Using Modified MobileNetV2 and LIME. https://app.cochat.ai/papers/10.3390/healthcare9091099
- The paper
- Ahsan, M. M., Nazim, R., Siddique, Z., & Huebner, P. (2021). Detection of COVID-19 Patients from CT Scan and Chest X-ray Data Using Modified MobileNetV2 and LIME. Healthcare. https://doi.org/10.3390/healthcare9091099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.