CoChat

Changes in Biomarkers of Tobacco Exposure among Cigarette Smokers Transitioning to ENDS Use: The Population Assessment of Tobacco and Health Study, 2013–2015

Open access
Anic, Gabriella M., Rostron, Brian L., Hammad, Hoda T., van Bemmel, Dana M., Del Valle-Pinero, Arseima Y., Christensen, Carol H., Erives, Gladys, Faulcon, Lisa M., Blount, Benjamin C., Wang, Yuesong, Wang, Lanqing, Bhandari, Deepak, Calafat, Antonia M., Kimmel, Heather L., Everard, Colm D., Compton, Wilson M., Edwards, Kathryn C., Goniewicz, Maciej L., Wei, Binnian, Hyland, Andrew, Hatsukami, Dorothy K., Hecht, Stephen S., Niaura, Raymond S., Borek, Nicolette, Ambrose, Bridget K., Chang, Cindy M. · 2022 · International Journal of Environmental Research and Public Health
Cited by 52

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Limited data are available for how biomarkers of tobacco exposure (BOE) change when cigarette smokers transition to using electronic nicotine delivery systems (ENDS). Using biomarker data from Waves 1 (2013–2014) and 2 (2014–2015) of the PATH Study, we examined how mean BOE concentrations, including metabolites of nicotine, tobacco-specific nitrosamines (TSNA), polycyclic aromatic hydrocarbons (PAH), and volatile organic compounds (VOC) and metals, changed when 2475 adult smokers transitioned to using ENDS or quit tobacco products. Exclusive smokers who transitioned to dual use had a significant decrease in NNAL (4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol), but not nicotine metabolites, most PAHs, metals, or VOCs. Exclusive smokers who became dual users had significant reductions in total nicotine equivalents, NNAL, and 2CyEMA (acrylonitrile metabolite), but only in those who reduced cigarettes per day (CPD) by >=50%. Smokers who transitioned to exclusive ENDS use had significant reductions in most TSNAs, PAHs, and VOCs; however, nicotine metabolites did not decrease in dual users who became exclusive ENDS users. Smokers who quit tobacco use had significant decreases in nicotine metabolites, all TSNAs, most PAHs, and most VOCs. Cigarette smokers who became dual users did not experience significant reductions in most BOEs. Reductions were impacted by changes in CPD. However, transitioning from smoking to no tobacco or exclusive ENDS use was associated with reduced exposure to most BOEs measured. Future analyses could incorporate additional waves of PATH data and examine changes in biomarker exposure by ENDS device type and CPD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijerph19031462

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Anic, G. M., Rostron, B. L., Hammad, H. T., van Bemmel, D. M., Del Valle-Pinero, A. Y., Christensen, C. H., Erives, G., Faulcon, L. M., Blount, B. C., Wang, Y., Wang, L., Bhandari, D., Calafat, A. M., Kimmel, H. L., Everard, C. D., Compton, W. M., Edwards, K. C., Goniewicz, M. L., Wei, B., Hyland, A., Hatsukami, D. K., Hecht, S. S., Niaura, R. S., Borek, N., Ambrose, B. K., & Chang, C. M.
Venue
International Journal of Environmental Research and Public Health
Publisher
MDPI AG
Published
2022-01-27
Volume
19
Issue
3
Pages
1462
ISSN
1660-4601 (ISSN-L)
OpenAlex
W4210611458
Cited by
52
References
6
FWCI
5.26
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.