The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Microfluidic Mixing: A Review
Open accessAbstract
The aim of microfluidic mixing is to achieve a thorough and rapid mixing of multiple samples in microscale devices. In such devices, sample mixing is essentially achieved by enhancing the diffusion effect between the different species flows. Broadly speaking, microfluidic mixing schemes can be categorized as either “active”, where an external energy force is applied to perturb the sample species, or “passive”, where the contact area and contact time of the species samples are increased through specially-designed microchannel configurations. Many mixers have been proposed to facilitate this task over the past 10 years. Accordingly, this paper commences by providing a high level overview of the field of microfluidic mixing devices before describing some of the more significant proposals for active and passive mixers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 2×
“[66] proposed an active micromixer based on electrohydrodynamic (EDH) forces.”
BackgroundZeta potential in colloid science : principles and applications
Hunter, R. J. (1981) · Cited by 1,942
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
Micro T-mixer as a rapid mixing micromixer
WONG, S., WARD, M., & Wharton, C. W. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.02.008 · Cited by 427
Ultrasonic micromixer for microfluidic systems
Yang, Z., Matsumoto, S., Goto, H., Matsumoto, M., & Maeda, R. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00654-9 · Cited by 421
A minute magneto hydro dynamic (MHD) mixer
Bau, H. H., Zhong, J., & Yi, M. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00851-6 · Cited by 371
Artificial cilia for active micro-fluidic mixing
Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., et al. (2008) · Lab on a Chip · doi:10.1039/b717681c · Cited by 296
A fast microfluidic mixer based on acoustically driven sidewall-trapped microbubbles
Ahmed, D., Mao, X., Juluri, B. K., & Huang, T. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0444-3 · Cited by 272
Hybridization Enhancement Using Cavitation Microstreaming
Liu, R. H., Lenigk, R., Druyor-Sanchez, R. L., Yang, J., & Grodzinski, P. (2003) · Analytical Chemistry · doi:10.1021/ac026267t · Cited by 244
Efficient spatial-temporal chaotic mixing in microchannels
Niu, X., & Lee, Y.-K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/3/316 · Cited by 244
A barrier embedded chaotic micromixer
Kim, D. S., Lee, S. W., Kwon, T. H., & Lee, S. S. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/006 · Cited by 236
A Picoliter-Volume Mixer for Microfluidic Analytical Systems
He, B., Burke, B. J., Zhang, X., Zhang, R., & Regnier, F. E. (2001) · Analytical Chemistry · doi:10.1021/ac000850x · Cited by 200
High-throughput micromixers based on acoustic streaming induced by surface acoustic wave
Luong, T.-D., Phan, V.-N., & Nguyen, N.-T. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0694-0 · Cited by 172
A rapid magnetic particle driven micromixer
Wang, Y., Zhe, J., Chung, B. T. F., & Dutta, P. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0188-x · Cited by 163
Self-citationA magnetohydrodynamic chaotic stirrer
Yi, M., Qian, S., & Bau, H. H. (2002) · Journal of Fluid Mechanics · doi:10.1017/s0022112002001635 · Cited by 134
Lin, C., Tsai, C., & Fu, L. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/5/006 · Cited by 122
Self-citationRapid magnetic microfluidic mixer utilizing AC electromagnetic field
Wen, C., Yeh, C.-P., Tsai, C., & Fu, L. (2009) · Electrophoresis · doi:10.1002/elps.200900400 · Cited by 116
Self-citationMilliseconds microfluidic chaotic bubble mixer
Mao, X., Juluri, B. K., Lapsley, M. I., Stratton, Z. S., & Huang, T. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0496-4 · Cited by 86
Kang, T. G., Singh, M., Anderson, P. D., & Meijer, H. E. H. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0437-2 · Cited by 66
Micromixer based on viscoelastic flow instability at low Reynolds number
Lam, Y. C., Gan, H. Y., Nguyen, N., & Lie, H. (2009) · Biomicrofluidics · doi:10.1063/1.3108462 · Cited by 52
High-throughput microparticle separation using gradient traveling wave dielectrophoresis
Choi, E., Kim, B., & Park, J. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/12/125014 · Cited by 39
An integrated microfluidic system for counting of CD4+/CD8+ T lymphocytes
Wang, J.-H., Wang, C., Lin, C.-C., Lei, H., & Lee, G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0687-z · Cited by 32
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Passive mixers in microfluidic systems: A review
Lee, C.-Y., Wang, W.-T., Liu, C.-C., & Fu, L.-M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.122 · Cited by 550
Self-citationActive and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Metadata
- Authors
- Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2011-05-18
- Volume
- 12
- Issue
- 5
- Pages
- 3263-3287
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W1978240589
- Cited by
- 1,111
- References
- 24
- FWCI
- 21.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.