The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Microfluidic Mixing: A Review
Open accessAbstract
The aim of microfluidic mixing is to achieve a thorough and rapid mixing of multiple samples in microscale devices. In such devices, sample mixing is essentially achieved by enhancing the diffusion effect between the different species flows. Broadly speaking, microfluidic mixing schemes can be categorized as either “active”, where an external energy force is applied to perturb the sample species, or “passive”, where the contact area and contact time of the species samples are increased through specially-designed microchannel configurations. Many mixers have been proposed to facilitate this task over the past 10 years. Accordingly, this paper commences by providing a high level overview of the field of microfluidic mixing devices before describing some of the more significant proposals for active and passive mixers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 2×
“[66] proposed an active micromixer based on electrohydrodynamic (EDH) forces.”
BackgroundZeta potential in colloid science : principles and applications
Hunter, R. J. (1981) · Cited by 1,942
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
Micro T-mixer as a rapid mixing micromixer
WONG, S., WARD, M., & Wharton, C. W. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.02.008 · Cited by 427
Ultrasonic micromixer for microfluidic systems
Yang, Z., Matsumoto, S., Goto, H., Matsumoto, M., & Maeda, R. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00654-9 · Cited by 421
A minute magneto hydro dynamic (MHD) mixer
Bau, H. H., Zhong, J., & Yi, M. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00851-6 · Cited by 371
Artificial cilia for active micro-fluidic mixing
Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., et al. (2008) · Lab on a Chip · doi:10.1039/b717681c · Cited by 296
A fast microfluidic mixer based on acoustically driven sidewall-trapped microbubbles
Ahmed, D., Mao, X., Juluri, B. K., & Huang, T. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0444-3 · Cited by 272
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Passive mixers in microfluidic systems: A review
Lee, C.-Y., Wang, W.-T., Liu, C.-C., & Fu, L.-M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.122 · Cited by 550
Self-citationActive and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Costa, C. M., Cardoso, V. F., Martins, P., Correia, D. M., Gonçalves, R., Costa, P., Correia, V., Ribeiro, C., Fernandes, M. M., Martins, P. M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00196 · Cited by 498
Cai, G., Xue, L., Zhang, H., & Lin, J. (2017) · Micromachines · doi:10.3390/mi8090274 · Cited by 467
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Droplet impact on superhydrophobic surfaces: A review of recent developments
Khojasteh, D., Kazerooni, M., Salarian, S., & Kamali, R. (2016) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2016.07.027 · Cited by 377
Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics
Sharma, S., Zapatero-Rodríguez, J., Estrela, P., & O'Kennedy, R. (2015) · Biosensors · doi:10.3390/bios5030577 · Cited by 349
Evers, M. J. W., Kulkarni, J. A., van der Meel, R., Cullis, P. R., Vader, P., & Schiffelers, R. M. (2018) · Small Methods · doi:10.1002/smtd.201700375 · Cited by 332
Maeki, M., Kimura, N., Sato, Y., Harashima, H., & Tokeshi, M. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.008 · Cited by 319
Acoustofluidics for biomedical applications
Rufo, J., Cai, F., Friend, J., Wiklund, M., & Huang, T. J. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00109-7 · Cited by 305
Dong, G., Chen, B., Liu, B., Hounjet, L. J., Cao, Y., Stoyanov, S. R., Yang, M., & Zhang, B. (2022) · Water Research · doi:10.1016/j.watres.2022.118047 · Cited by 303
Why microfluidics? Merits and trends in chemical synthesis
Liu, Y., & Jiang, X. (2017) · Lab on a Chip · doi:10.1039/c7lc00627f · Cited by 291
Isothermal Amplification Methods for the Detection of Nucleic Acids in Microfluidic Devices
Zanoli, L., & Spoto, G. (2012) · Biosensors · doi:10.3390/bios3010018 · Cited by 265
Recent advances and current challenges in magnetophoresis based micro magnetofluidics
Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T. (2018) · Biomicrofluidics · doi:10.1063/1.5035388 · Cited by 164
Li, F., Macdonald, N. P., Guijt, R. M., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03228 · Cited by 74
Toward improved in vitro models of human cancer
Ayuso, J. M., Park, K.-Y., Virumbrales-Muñoz, M., & Beebe, D. J. (2021) · APL Bioengineering · doi:10.1063/5.0026857 · Cited by 40
Size, Morphology and Crystallinity Control Strategy of Ultrafine HMX by Microfluidic Platform
Jiang, H., Wang, X., Yu, J., Zhou, W., Zhao, S., Xu, S., & Zhao, F. (2023) · Nanomaterials · doi:10.3390/nano13030464 · Cited by 24
Magnetofluidic micromixer based on a complex rotating magnetic field
Munaz, A., Kamble, H., Shiddiky, M. J. A., & Nguyen, N.-T. (2017) · RSC Advances · doi:10.1039/c7ra08073e · Cited by 23
Metadata
- Authors
- Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2011-05-18
- Volume
- 12
- Issue
- 5
- Pages
- 3263-3287
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W1978240589
- Cited by
- 1,111
- References
- 24
- FWCI
- 21.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.