CoChat

The Effects of Novel Pulsed Electromagnetic Field Therapy Device on Acute Distal Radius Fractures: A Prospective, Double-Blind, Sham-Controlled, Randomized Pilot Study

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Background: this pilot study aimed at determining whether the application of a novel new method of generating pulsed electromagnetic field (PEMF), the Fracture Healing Patch (FHP), accelerates the healing of acute distal radius fractures (DRF) when compared to a sham treatment. Methods: 41 patients with DRFs treated with cast immobilization were included. Patients were allocated to a PEMF group (n = 20) or a control (sham) group (n = 21). All patients were assessed with regard to functional and radiological outcomes (X-rays and CT scans) at 2, 4, 6 and 12 weeks. Results: fractures treated with active PEMF demonstrated significantly higher extent of union at 4 weeks as assessed by CT (76% vs. 58%, p = 0.02). SF12 mean physical score was significantly higher in PEMF treated group (47 vs. 36, p = 0.005). Time to cast removal was significantly shorter in PEMF treated patients, 33 ± 5.9 days in PEMF vs. 39.8 ± 7.4 days in sham group (p = 0.002). Conclusion: early addition of PEMF treatment may accelerate bone healing which could lead to a shorter cast immobilization, thus allowing an earlier return to daily life activities and work. There were no complications related to the PEMF device (FHP).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm12051866

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The treatment equipment used in the study. (A) A set of Pulsar FHP and activator; (B) activated or sham FHP placed on the patient’s hand over the Velband dressing; (C) schematic presentation of the FHP under the cast; (D) representative X-ray, of the FHP placed under the cast (lateral view).
Figure 1 The treatment equipment used in the study. (A) A set of Pulsar FHP and activator; (B) activated or sham FHP placed on the patient’s hand over the Velband dressing; (C) schematic presentation of the FHP under the cast; (D) representative X-ray, of the FHP placed under the cast (lateral view).CC BY · PubMed Central
Figure 2 Study consort flow diagram demonstrating the method of patient recruitment.
Figure 2 Study consort flow diagram demonstrating the method of patient recruitment.CC BY · PubMed Central
Figure 3 Radiological assessment of percentage of the extent of fracture union at 4 weeks as assessed by CT. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.
Figure 3 Radiological assessment of percentage of the extent of fracture union at 4 weeks as assessed by CT. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.CC BY · PubMed Central
Figure 4 Radiological assessment of fracture healing at 2 and 6 weeks by X-rays, using RUSS. Graphs are reported as mean ± SE. Student’s t-test. (A) At 2 weeks follow-up. (B) At 6 weeks follow-up.* Statistically significant.
Figure 4 Radiological assessment of fracture healing at 2 and 6 weeks by X-rays, using RUSS. Graphs are reported as mean ± SE. Student’s t-test. (A) At 2 weeks follow-up. (B) At 6 weeks follow-up.* Statistically significant.CC BY · PubMed Central
Figure 5 Assessment of functional outcome in terms of wrist range of movement as measured at 6, 12 and 24 weeks. (A) Flexion was significantly better in the PEMF treated patients at 12 and 24 weeks. (B–D) All other parameters were slightly better in PEMF treated group, however not statistically significant. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.
Figure 5 Assessment of functional outcome in terms of wrist range of movement as measured at 6, 12 and 24 weeks. (A) Flexion was significantly better in the PEMF treated patients at 12 and 24 weeks. (B–D) All other parameters were slightly better in PEMF treated group, however not statistically significant. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.CC BY · PubMed Central
Figure 6 Assessment of functional outcome using PRWE. (A) Pain sub-score was better in the PEMF group at week 12 (p = 0.06). (B) No differences were found in the function sub-score between groups. (C) Total PRWE score was better in PEMF treated patients at 12 weeks, however not statistically significant (p = 0.07). Graphs are reported as mean ± SE. Student’s t-test.
Figure 6 Assessment of functional outcome using PRWE. (A) Pain sub-score was better in the PEMF group at week 12 (p = 0.06). (B) No differences were found in the function sub-score between groups. (C) Total PRWE score was better in PEMF treated patients at 12 weeks, however not statistically significant (p = 0.07). Graphs are reported as mean ± SE. Student’s t-test.CC BY · PubMed Central
Figure 7 Assessment of patients physical and mental wellbeing using SF 12. (A) SF12 physical score was significantly higher in PEMF treated group at 12 weeks. (B) No differences were noticed in the SF12 mental score. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.
Figure 7 Assessment of patients physical and mental wellbeing using SF 12. (A) SF12 physical score was significantly higher in PEMF treated group at 12 weeks. (B) No differences were noticed in the SF12 mental score. Graphs are reported as mean ± SE. Student’s t-test. * Statistically significant.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 21

Metadata

Authors
Factor, S., Druckmann, I., Atlan, F., Rosenblatt, Y., Tordjman, D., Krespi, R., Kazum, E., Pritsch, T., & Eisenberg, G.
Affiliations
Tel Aviv University (IL)
Corresponding author
Factor, Shai
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2023-02-27
Volume
12
Issue
5
Pages
1866
ISSN
2077-0383 (ISSN-L)
OpenAlex
W4322503485
Cited by
20
References
32
Citations by year
2026: 6 · 2025: 4 · 2024: 9 · 2023: 1
FWCI
3.99
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
  • Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
Keywords
pulsed electromagnetic field therapy, distal radius fracture, fracture healing, cast immobilization, fracture union, functional outcome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.