The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay
The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Catalytically active nanomaterials, in particular, nanozymes, are promising candidates for applications in biosensors due to their excellent catalytic activity, stability and cost-effective preparation. Nanozymes with peroxidase-like activities are prospective candidates for applications in biosensors. The purpose of the current work is to develop cholesterol oxidase-based amperometric bionanosensors using novel nanocomposites as peroxidase (HRP) mimetics. To select the most electroactive chemosensor on hydrogen peroxide, a wide range of nanomaterials were synthesized and characterized using cyclic voltammetry (CV) and chronoamperometry. Pt NPs were deposited on the surface of a glassy carbon electrode (GCE) in order to improve the conductivity and sensitivity of the nanocomposites. The most HRP-like active bi-metallic CuFe nanoparticles (nCuFe) were placed on a previously nano-platinized electrode, followed by conjugation of cholesterol oxidase (ChOx) in a cross-linking film formed by cysteamine and glutaraldehyde. The constructed nanostructured bioelectrode ChOx/nCuFe/nPt/GCE was characterized by CV and chronoamperometry in the presence of cholesterol. The bionanosensor (ChOx/nCuFe/nPt/GCE) shows a high sensitivity (3960 A·M−1·m−2) for cholesterol, a wide linear range (2–50 µM) and good storage stability at a low working potential (−0.25 V vs. Ag/AgCl/3 M KCl). The constructed bionanosensor was tested on a real serum sample. A detailed comparative analysis of the bioanalytical characteristics of the developed cholesterol bionanosensor and the known analogs is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms and regulation of cholesterol homeostasis
Luo, J., Yang, H., & Song, B.-L. (2020) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-019-0190-7 · Cited by 1,980
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Karyakin, A. A., Karyakina, E. E., & Gorton, L. (2000) · Analytical Chemistry · doi:10.1021/ac990801o · Cited by 419
Ruecha, N., Rangkupan, R., Rodthongkum, N., & Chailapakul, O. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.018 · Cited by 342
Jung, E., Kong, S. Y., Ro, Y. S., Ryu, H. H., & Shin, S. D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148272 · Cited by 211
Cholesterol biosensors: A review
Narwal, V., Deswal, R., Batra, B., Kalra, V., Hooda, R., Sharma, M., & Rana, J. S. (2019) · Steroids · doi:10.1016/j.steroids.2018.12.003 · Cited by 191
Lin, X., Ni, Y., & Serge Kokot, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.019 · Cited by 160
Nanomaterials towards fabrication of cholesterol biosensors: Key roles and design approaches
Saxena, U., & Das, A. B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.042 · Cited by 135
High-performance electrochemical biosensor for the detection of total cholesterol
Ahmadalinezhad, A., & Chen, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.011 · Cited by 128
Nanozymes towards Personalized Diagnostics: A Recent Progress in Biosensing
Kurup, C. P., & Ahmed, M. U. (2023) · Biosensors · doi:10.3390/bios13040461 · Cited by 126
Research works printed but not linked: 2
- Alagappan, 2020, Development of cholesterol biosensor using Au nanoparticles decorated f-MWCNT covered with polypyrrole network, Arab. J. Chem., 13, 2001, 10.1016/j.arabjc.2018.02.018 · DOI
- Sibirnyj, 2021, The use of enzymes for ethanol, methanol and formaldehyde determination in food products, J. Microbiol. Biotechnol. Food Sci., 2021, 393
Metadata
- Authors
- Demkiv, O., Nogala, W., Stasyuk, N., Grynchyshyn, N., Vus, B., & Gonchar, M.
- Venue
- Journal of Functional Biomaterials
- Publisher
- MDPI AG
- Published
- 2023-06-07
- Volume
- 14
- Issue
- 6
- Pages
- 315
- ISSN
- 2079-4983
- Cited by
- 15
- References
- 64
- Language
- en
- Funders
- National Research Foundation of Ukraine (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
- National Science Centre, Poland (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
- FEBS Ukrainian Short-Term Fellowship (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay. https://app.cochat.ai/papers/10.3390/jfb14060315
- The paper
- Demkiv, O., Nogala, W., Stasyuk, N., Grynchyshyn, N., Vus, B., & Gonchar, M. (2023). The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay. Journal of Functional Biomaterials. https://doi.org/10.3390/jfb14060315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.