The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay
The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Catalytically active nanomaterials, in particular, nanozymes, are promising candidates for applications in biosensors due to their excellent catalytic activity, stability and cost-effective preparation. Nanozymes with peroxidase-like activities are prospective candidates for applications in biosensors. The purpose of the current work is to develop cholesterol oxidase-based amperometric bionanosensors using novel nanocomposites as peroxidase (HRP) mimetics. To select the most electroactive chemosensor on hydrogen peroxide, a wide range of nanomaterials were synthesized and characterized using cyclic voltammetry (CV) and chronoamperometry. Pt NPs were deposited on the surface of a glassy carbon electrode (GCE) in order to improve the conductivity and sensitivity of the nanocomposites. The most HRP-like active bi-metallic CuFe nanoparticles (nCuFe) were placed on a previously nano-platinized electrode, followed by conjugation of cholesterol oxidase (ChOx) in a cross-linking film formed by cysteamine and glutaraldehyde. The constructed nanostructured bioelectrode ChOx/nCuFe/nPt/GCE was characterized by CV and chronoamperometry in the presence of cholesterol. The bionanosensor (ChOx/nCuFe/nPt/GCE) shows a high sensitivity (3960 A·M−1·m−2) for cholesterol, a wide linear range (2–50 µM) and good storage stability at a low working potential (−0.25 V vs. Ag/AgCl/3 M KCl). The constructed bionanosensor was tested on a real serum sample. A detailed comparative analysis of the bioanalytical characteristics of the developed cholesterol bionanosensor and the known analogs is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms and regulation of cholesterol homeostasis
Luo, J., Yang, H., & Song, B.-L. (2020) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-019-0190-7 · Cited by 1,980
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Karyakin, A. A., Karyakina, E. E., & Gorton, L. (2000) · Analytical Chemistry · doi:10.1021/ac990801o · Cited by 419
Ruecha, N., Rangkupan, R., Rodthongkum, N., & Chailapakul, O. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.018 · Cited by 342
Jung, E., Kong, S. Y., Ro, Y. S., Ryu, H. H., & Shin, S. D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148272 · Cited by 211
Cholesterol biosensors: A review
Narwal, V., Deswal, R., Batra, B., Kalra, V., Hooda, R., Sharma, M., & Rana, J. S. (2019) · Steroids · doi:10.1016/j.steroids.2018.12.003 · Cited by 191
Lin, X., Ni, Y., & Serge Kokot, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.019 · Cited by 160
Nanomaterials towards fabrication of cholesterol biosensors: Key roles and design approaches
Saxena, U., & Das, A. B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.042 · Cited by 135
High-performance electrochemical biosensor for the detection of total cholesterol
Ahmadalinezhad, A., & Chen, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.011 · Cited by 128
Nanozymes towards Personalized Diagnostics: A Recent Progress in Biosensing
Kurup, C. P., & Ahmed, M. U. (2023) · Biosensors · doi:10.3390/bios13040461 · Cited by 126
Zhang, Y., Wang, Y., Sun, X., Chen, L., & Xu, Z. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.059 · Cited by 123
Cai, X., Gao, X., Wang, L., Wu, Q., & Lin, X. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.050 · Cited by 106
Bonomi, R., Cazzolaro, A., Sansone, A., Scrimin, P., & Prins, L. J. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201007389 · Cited by 100
Ahmida, H. S. M. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.05.024 · Cited by 96
A cholesterol biosensor based on a bi-enzyme immobilized on conducting poly(thionine) film
Rahman, M. M., Li, X., Kim, J., Lim, B. O., Ahammad, A. J. S., & Lee, J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.114 · Cited by 96
Optimized fabrication of newly cholesterol biosensor based on nanocellulose
Abdi, M. M., Razalli, R. L., Tahir, P. M., Chaibakhsh, N., Hassani, M., & Mir, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.01.001 · Cited by 91
A chitosan-based polyaniline–Au nanocomposite biosensor for determination of cholesterol
Srivastava, M., Srivastava, S., Nirala, N. R., & Prakash, R. (2013) · Analytical Methods · doi:10.1039/c3ay41812j · Cited by 85
Cholesterol Oxidase Senses Subtle Changes in Lipid Bilayer Structure
Ahn, K.-W., & Sampson, N. S. (2004) · Biochemistry · doi:10.1021/bi035697q · Cited by 78
Eom, K. S., Lee, Y. J., Seo, H. W., Kang, J. Y., Shim, J. S., & Lee, S. H. (2020) · The Analyst · doi:10.1039/c9an01679a · Cited by 76
Recent advances in carbon nanotubes-based biocatalysts and their applications
Kumari, A., Rajeev, R., Benny, L., Sudhakar, Y. N., Varghese, A., & Hegde, G. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102542 · Cited by 73
Stewart, A. J., O’Reilly, E. J., Moriarty, R. D., Bertoncello, P., Keyes, T. E., Forster, R. J., & Dennany, L. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.01.073 · Cited by 69
Komathi, S., Gopalan, A., Kim, S., Saianand, G., & Lee, K.-P. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.01.032 · Cited by 67
Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin
Zhao, C., Wan, L. J., Li, J., Wang, Q. L., & Jiao, K. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.08.022 · Cited by 64
Central nervous system cholesterol metabolism in health and disease
Ho, W. Y., Hartmann, H., & Ling, S. (2022) · IUBMB Life · doi:10.1002/iub.2662 · Cited by 62
Porous ZnO microtubes with excellent cholesterol sensing and catalytic properties
Giri, A. K., Sinhamahapatra, A., Prakash, S., Chaudhari, J. C., Shahi, V. K., & Panda, A. B. (2013) · Journal of Materials Chemistry A · doi:10.1039/c2ta00107a · Cited by 54
Hojo, K., Hakamata, H., Ito, A., Kotani, A., Furukawa, C., Hosokawa, Y., & Kusu, F. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.020 · Cited by 51
Liu, X., Nan, Z., Qiu, Y., Zheng, L., & Lu, X. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.11.119 · Cited by 49
Rashidi, K., Mahmoudi, M., Mohammadi, G., Zangeneh, M. M., Korani, S., Goicoechea, H. C., Gu, H., & Jalalvand, A. R. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.08.163 · Cited by 47
Kaçar, C., Erden, P. E., Dalkıran, B., İnal, E. K., & Kιlιç, E. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02448-4 · Cited by 45
Pramanik, K., Sarkar, P., Bhattacharyay, D., & Majumdar, P. (2018) · Electroanalysis · doi:10.1002/elan.201800318 · Cited by 36
Lütjohann, D., Björkhem, I., Friedrichs, S., Kerksiek, A., Lövgren‐Sandblom, A., Geilenkeuser, W., Ahrends, R., Andrade, I. A. L. D. A., Ansorena, D., Astiasarán, I., et al. (2019) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2019.03.025 · Cited by 36
Dey, R. S., & Raj, C. R. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.063 · Cited by 36
Doaga, R., McCormac, T., & Dempsey, E. (2020) · Microchimica Acta · doi:10.1007/s00604-020-4203-1 · Cited by 31
Batra, B., Narwal, V., Sumit, S., Ahlawat, J., & Sharma, M. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100111 · Cited by 31
Nanomaterials as Redox Mediators in Laccase-Based Amperometric Biosensors for Catechol Assay
Demkiv, O. M., Gayda, G. Z., Stasyuk, N. Y., Brahinetz, O., Gonchar, M. V., & Nisnevitch, M. (2022) · Biosensors · doi:10.3390/bios12090741 · Cited by 22
Self-citationMurakami, K., Harada, A., Toh, R., Kubo, T., Miwa, K., Kim, J., Kiriyama, M., Iino, T., Nishikawa, Y., Uno, S., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-28953-x · Cited by 15
Cerium Oxide/Polypyrrole Nanocomposite as the Matrix for Cholesterol Biosensor
Anh, T. T. N., Van Thu, V., Dang, H.-S., Pham, V.-H., & Tam, P. D. (2021) · Advances in Polymer Technology · doi:10.1155/2021/6627645 · Cited by 14
Shi, R., Chen, J., Wan, X., & Tian, J. (2023) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/acbac2 · Cited by 5
Huang, Y., Cui, L., Xue, Y., Zhang, S., Zhu, N., Liang, J., & Li, G. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.253
Eguílaz, M., Villalonga, R., Agüı́, L., Yáñez‐Sedeño, P., & Pingarrón, J. M. (2011) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2011.07.040
Çevik, E., Cerit, A., Gazel, N., & Yıldız, H. B. (2018) · Electroanalysis · doi:10.1002/elan.201800248
Nantaphol, S., Chailapakul, O., & Siangproh, W. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.041
Li, X., Xu, J., & Chen, H. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.08.020
Sharma, D., Lee, J., Seo, J., & Shin, H. (2017) · Sensors · doi:10.3390/s17092128
Determination of Total Cholesterol in Serum by Gas Chromatography-Mass Spectrometry
Lian, K., Zhang, P., Wang, W., Dai, T., & Li, L. (2014) · Asian Journal of Chemistry · doi:10.14233/ajchem.2014.15780
Li, Z., Xie, C., Wang, J., Meng, A., & Zhang, F. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.11.054
Nano-Rods Structured Cerium Oxide Platform for Cholesterol Biosensor
Anh, T. T. N., Tam, L. T., Thu, V. V., Le, A., Hung, V., & Tam, P. D. (2020) · Journal of Inorganic and Organometallic Polymers and Materials · doi:10.1007/s10904-020-01527-4
Silva, D. P. B., Miyazaki, C. M., Mascagni, D. B. T., & Ferreira, M. (2019) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2019.16534
Cao, S., Zhang, L., Chai, Y., & Yuan, R. (2013) · Talanta · doi:10.1016/j.talanta.2013.02.002
Haritha, V. S., Kumar, S. R. S., & Rakhi, R. B. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.03.128
Liu, L., Jingshan, W., Wang, J., Wu, J., Wu, S., & Xie, L. (2021) · ChemistrySelect · doi:10.1002/slct.202102053
Rastogi, L., Dash, K., & Sashidhar, R. B. (2021) · Current Research in Biotechnology · doi:10.1016/j.crbiot.2021.02.001
ZnO nanowire-based fluorometric enzymatic assays for lactate and cholesterol
Briones, M., Busó‐Rogero, C., Catalán‐Gómez, S., García‐Mendiola, T., Pariente, F., Redondo‐Cubero, A., & Lorenzo, E. (2020) · Microchimica Acta · doi:10.1007/s00604-020-4137-7
Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol–gel film
Kumar, A., Malhotra, R., Malhotra, B. D., & Sk, G. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00792-3
Amperometric Cholesterol Determination Using HRP Incorporated Carbon Paste Electrode
Hooda, V., & Gahlaut, A. (2020) · Biosciences Biotechnology Research Asia · doi:10.13005/bbra/2809
Yan, Q., Wu, R., Chen, H., Wang, H., & Nan, W. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.108201
A cholesterol biosensor based on gold nanoparticles decorated functionalized graphene nanoplatelets
Aravind, S. S. J., Baby, T. T., Arockiadoss, T., Rakhi, R. B., & Ramaprabhu, S. (2011) · Thin Solid Films · doi:10.1016/j.tsf.2011.03.032
An Au nanocomposite based biosensor for determination of cholesterol
Xu, L., Zhang, M., Hou, Y., Huang, W., Yao, C., & Wu, Q. (2015) · Analytical Methods · doi:10.1039/c5ay00376h
Cu-Pt-Bi Nanocomposite Modified Glassy Carbon Electrode for Dual Mode H2O2and Cholesterol Sensing
Soorya, V. C., & Berchmans, S. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0801709jes
Gopalan, A., Lee, K.-P., & Dhanusuraman, R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.11.034
Jerez-Masaquiza, M. D., Fernández, L., González, G., Montero-Jiménez, M., & Espinoza-Montero, P. J. (2020) · Nanomaterials · doi:10.3390/nano10071328
Stasyuk, N. Y., Demkiv, O. M., Gayda, G. Z., Zakalskiy, A. E., Клепач, Г. М., Anatoliivna, B. N., Gonchar, M. V., & Nisnevitch, M. (2022) · Biosensors · doi:10.3390/bios12070472
Self-citationLiu, J., Cheng, H., Xie, H., Luo, G., Niu, Y., Zhang, S., Li, G., & Sun, W. (2019) · RSC Advances · doi:10.1039/c9ra06265c
Peroxidase-Like Metal-Based Nanozymes: Synthesis, Catalytic Properties, and Analytical Application
Demkiv, O. M., Stasyuk, N. Y., Serkiz, R. Y., Gayda, G. Z., Nisnevitch, M., & Gonchar, M. V. (2021) · Applied Sciences · doi:10.3390/app11020777
Self-citation
Research works printed but not linked: 2
- Alagappan, 2020, Development of cholesterol biosensor using Au nanoparticles decorated f-MWCNT covered with polypyrrole network, Arab. J. Chem., 13, 2001, 10.1016/j.arabjc.2018.02.018 · DOI
- Sibirnyj, 2021, The use of enzymes for ethanol, methanol and formaldehyde determination in food products, J. Microbiol. Biotechnol. Food Sci., 2021, 393
Metadata
- Authors
- Demkiv, O., Nogala, W., Stasyuk, N., Grynchyshyn, N., Vus, B., & Gonchar, M.
- Venue
- Journal of Functional Biomaterials
- Publisher
- MDPI AG
- Published
- 2023-06-07
- Volume
- 14
- Issue
- 6
- Pages
- 315
- ISSN
- 2079-4983
- Cited by
- 15
- References
- 64
- Language
- en
- Funders
- National Research Foundation of Ukraine (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
- National Science Centre, Poland (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
- FEBS Ukrainian Short-Term Fellowship (2020.02/0100, 2021.01/0010, 2016/23/B/ST4/02868)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.