CoChat

Experimental Study of an Enhanced Phase Change Material of Paraffin/Expanded Graphite/Nano-Metal Particles for a Personal Cooling System

Open access
Ma, Chuyuan, Zhang, Ying, Chen, Xianfeng, Song, Xiande, Tang, Kaixuan · 2020 · Materials

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

A composite phase change material (PCM) was prepared by incorporating paraffin (PA) with expanded graphite (EG) and nano-metal particles to improve the thermal conductivity and reduce the leakage performance of PA once it melts and, consequently, develop a more efficient PCM for a personal phase change cooling system. A series of experiments was carried out by a scanning electron microscope, a differential scanning calorimeter, a hot-disk thermal analyzer, and leakage tests on the composite PCM with various mass fractions of EG and metals (i.e., Cu, Al, Ni, and Fe). Through comprehensive consideration of the thermal conductivity, leakage, and homogeneity, a composite PCM with the optimal proportion (PA-EG11%-Cu1.9%) was screened out. Its thermal conductivity was significantly improved nine times, while the phase change enthalpy showed a minimal decrease. In addition, the relationships of the composite PCM with its temperature and density were systematically investigated. The experimental results are important for determining the proper package density of PCM for application into a personal cooling system because its weight is crucial for the system design and benefits the performance comparison of various PCMs prepared under various conditions. Lastly, the heat storage efficiency of the PA–EG–Cu material was investigated using heat storage tests. Cooling performance clearly improved compared to the PCM without nano-particles added.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ma13040980

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Preparation of composite phase change material (PCM).
Figure 1 Preparation of composite phase change material (PCM).CC BY · PubMed Central
Figure 2 Paraffin-expanded graphite (PA-EG) mold.
Figure 2 Paraffin-expanded graphite (PA-EG) mold.CC BY · PubMed Central
Figure 3 Heat storage experiment.
Figure 3 Heat storage experiment.CC BY · PubMed Central
Figure 4 Penetration of different mass fractions: (a) EG—5%, (b) EG—8%, (c) EG—11%, and (d) EG—15%.
Figure 4 Penetration of different mass fractions: (a) EG—5%, (b) EG—8%, (c) EG—11%, and (d) EG—15%.CC BY · PubMed Central
Figure 5 SEM (scanning electron microscope) analysis of PA-EG: (a) 500× magnification, (b) 2000× magnification, (c) 1500× magnification, and (d) 800× magnification.
Figure 5 SEM (scanning electron microscope) analysis of PA-EG: (a) 500× magnification, (b) 2000× magnification, (c) 1500× magnification, and (d) 800× magnification.CC BY · PubMed Central
Figure 6 SEM analysis of PA-EG-Cu: (a) 800× magnification, (b) 10,000× magnification, (c) 10,000× magnification, and (d) 20,000× magnification.
Figure 6 SEM analysis of PA-EG-Cu: (a) 800× magnification, (b) 10,000× magnification, (c) 10,000× magnification, and (d) 20,000× magnification.CC BY · PubMed Central
Figure 7 SEM analysis of PA-EG-Al: (a) 10,000× magnification, (b) 20,000× magnification, (c) 5000× magnification, and (d) 800× magnification.
Figure 7 SEM analysis of PA-EG-Al: (a) 10,000× magnification, (b) 20,000× magnification, (c) 5000× magnification, and (d) 800× magnification.CC BY · PubMed Central
Figure 8 SEM analysis of PA-EG-Fe: (a) 20,000× magnification, (b) 800× magnification, (c) 5000× magnification, and (d) 10,000× magnification.
Figure 8 SEM analysis of PA-EG-Fe: (a) 20,000× magnification, (b) 800× magnification, (c) 5000× magnification, and (d) 10,000× magnification.CC BY · PubMed Central
Figure 9 SEM analysis of PA-EG-Ni: (a) 800× magnification, (b) 10,000× magnification, (c) 20,000× magnification, and (d) 5000× magnification.
Figure 9 SEM analysis of PA-EG-Ni: (a) 800× magnification, (b) 10,000× magnification, (c) 20,000× magnification, and (d) 5000× magnification.CC BY · PubMed Central
Figure 10 Differential scanning calorimeter (DSC) analysis of PA.
Figure 10 Differential scanning calorimeter (DSC) analysis of PA.CC BY · PubMed Central
Figure 11 DSC analysis of PA-EG.
Figure 11 DSC analysis of PA-EG.CC BY · PubMed Central
Figure 12 DSC analysis of PA-EG-nano-metal particles.
Figure 12 DSC analysis of PA-EG-nano-metal particles.CC BY · PubMed Central
Figure 13 DSC with different mass fractions analysis of PA-EG-Cu.
Figure 13 DSC with different mass fractions analysis of PA-EG-Cu.CC BY · PubMed Central
Figure 14 Comparison of the phase change temperature and phase change enthalpy.
Figure 14 Comparison of the phase change temperature and phase change enthalpy.CC BY · PubMed Central
Figure 15 Comparison of the phase change temperature and phase change enthalpy.
Figure 15 Comparison of the phase change temperature and phase change enthalpy.CC BY · PubMed Central
Figure 16 Thermal conductivity of different nano-metals with different mass fractions.
Figure 16 Thermal conductivity of different nano-metals with different mass fractions.CC BY · PubMed Central
Figure 17 Thermal conductivity at different temperatures.
Figure 17 Thermal conductivity at different temperatures.CC BY · PubMed Central
Figure 18 Heat storage curve of PA-EG.
Figure 18 Heat storage curve of PA-EG.CC BY · PubMed Central
Figure 19 Heat storage curve of PA-EG-Cu.
Figure 19 Heat storage curve of PA-EG-Cu.CC BY · PubMed Central
Figure 20 Thermal conductivity at different densities.
Figure 20 Thermal conductivity at different densities.CC BY · PubMed Central
Figure 21 Mass loss curve.
Figure 21 Mass loss curve.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 87

Metadata

Authors
Ma, C., Zhang, Y., Chen, X., Song, X., & Tang, K.
Affiliations
Wuhan University of Technology (CN)
Corresponding author
Tang, Kaixuan
Venue
Materials
Publisher
MDPI AG
Published
2020-02-22
Volume
13
Issue
4
Pages
980
ISSN
1996-1944 (ISSN-L)
OpenAlex
W3006864822
Cited by
80
References
42
Citations by year
2026: 7 · 2025: 15 · 2024: 11 · 2023: 14 · 2022: 20 · 2021: 11 · 2020: 2
FWCI
5.78
Type
journal article
Language
en
Open access
Locations
  • Materials (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Natural Science Foundation of China (51404178, 51706164)
  • National Key R&D Program of China (2017YFC0804700)
  • Hong Kong Scholar Program (XJ2015037)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
Keywords
phase change materials, alkanes, expanded graphite, copper nanoparticles, thermal conductivity enhancement, leakage reduction, personal cooling systems, heat storage efficiency, transition enthalpy, density-temperature relationship

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.