The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Biocompatibility of Advanced Manufactured Titanium Implants—A Review
Open accessAbstract
Titanium (Ti) and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing) or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
The future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
Biomedical applications of titanium and its alloys
Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008) · JOM · doi:10.1007/s11837-008-0031-1 · Cited by 983
Al-Bermani, S. S., Blackmore, M., Zhang, W., & Todd, I. (2010) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-010-0397-x · Cited by 860
Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Parthasarathy, J., Starly, B., Raman, S., & Christensen, A. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.10.006 · Cited by 816
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
Additive manufacturing (AM) and nanotechnology: promises and challenges
Ivanova, O., Williams, C., & Campbell, T. (2013) · Rapid Prototyping Journal · doi:10.1108/rpj-12-2011-0127 · Cited by 461
Selective Laser Melting: A manufacturing technology for the future?
Bremen, S., Meiners, W., & Diatlov, A. (2012) · Laser Technik Journal · doi:10.1002/latj.201290018 · Cited by 402
Study on microstructure and mechanical properties of laser rapid forming Inconel 718
Zhao, X., Chen, J., Lin, X., & Huang, W. (2008) · Materials Science and Engineering: A · doi:10.1016/j.msea.2007.05.079 · Cited by 401
Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
Schiff, N., Grosgogeat, B., Lissac, M., & Dalard, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00328-3 · Cited by 386
Physico-chemical considerations of titanium as a biomaterial
Tengvall, P., & Lundström, I. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90056-y · Cited by 373
Warnke, P. H., Douglas, T., Wollny, P., Sherry, E., Steiner, M., Galonska, S., Becker, S. T., Springer, I. N., Wiltfang, J., & Sivananthan, S. (2009) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2008.0288 · Cited by 305
In vivo performance of selective electron beam‐melted Ti‐6Al‐4V structures
Ponader, S., von Wilmowsky, C., Widenmayer, M., Lutz, R., Heinl, P., Körner, C., Singer, R. F., Nkenke, E., Neukam, F. W., & Schlegel, K. A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32337 · Cited by 179
Palmquist, A., Snis, A., Emanuelsson, L., Browne, M., & Thomsen, P. (2011) · Journal of Biomaterials Applications · doi:10.1177/0731684411431857 · Cited by 144
Thomsen, P., Malmström, J., Emanuelsson, L., René, M., & Snis, A. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31250 · Cited by 131
Printing of Titanium implant prototype
Wiria, F. E., Shyan, J. Y. M., Lim, P. N., Wen, F. G. C., Yeo, J. F., & Cao, T. (2010) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2009.12.050 · Cited by 99
Early Human Bone Response to Laser Metal Sintering Surface Topography: A Histologic Report
Mangano, C., Piattelli, A., d'Avila, S., et al. (2010) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-09-00003 · Cited by 64
Cytocompatibility of titanium metal injection molding with various anodic oxidation post-treatments
Demangel, C., Auzene, D., Vayssade, M., Duval, J.-L., Vigneron, P., Nagel, M. D., & Puippe, J. C. (2012) · Materials Science and Engineering C · doi:10.1016/j.msec.2012.05.037 · Cited by 22
Cited by
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Surface texture metrology for metal additive manufacturing: a review
Townsend, A., Senin, N., Blunt, L., Leach, R. K., & Taylor, J. S. (2016) · Precision Engineering · doi:10.1016/j.precisioneng.2016.06.001 · Cited by 743
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Titanium Alloys for Dental Implants: A Review
W. Nicholson, J. (2020) · Prosthesis · doi:10.3390/prosthesis2020011 · Cited by 461
Zhang, L.-C., Chen, L.-Y., & Wang, L. (2020) · Advanced Engineering Materials · doi:10.1002/adem.201901258 · Cited by 456
Metadata
- Authors
- Sidambe, A.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2014-12-19
- Volume
- 7
- Issue
- 12
- Pages
- 8168-8188
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2129012148
- Cited by
- 741
- References
- 18
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.