Transendothelial Electrical Resistance Measurement across the Blood–Brain Barrier: A Critical Review of Methods
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The blood–brain barrier (BBB) represents the tightest endothelial barrier within the cardiovascular system characterized by very low ionic permeability. Our aim was to describe the setups, electrodes, and instruments to measure electrical resistance across brain microvessels and culture models of the BBB, as well as critically assess the influence of often neglected physical and technical parameters such as temperature, viscosity, current density generated by different electrode types, surface size, circumference, and porosity of the culture insert membrane. We demonstrate that these physical and technical parameters greatly influence the measurement of transendothelial electrical resistance/resistivity (TEER) across BBB culture models resulting in severalfold differences in TEER values of the same biological model, especially in the low-TEER range. We show that elevated culture medium viscosity significantly increases, while higher membrane porosity decreases TEER values. TEER data measured by chopstick electrodes can be threefold higher than values measured by chamber electrodes due to different electrode size and geometry, resulting in current distribution inhomogeneity. An additional shunt resistance at the circumference of culture inserts results in lower TEER values. A detailed description of setups and technical parameters is crucial for the correct interpretation and comparison of TEER values of BBB models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Structure and function of the blood–brain barrier
Abbott, N. J., Patabendige, A. A. K., Dolman, D. E. M., Yusof, S. R., & Begley, D. J. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.07.030 · Cited by 5,185 · cited 1×
“The interendothelial tight junctions of brain microvessels create the basis of this physical defense system which restricts the movement of ions through the paracellular space, thus contributing greatly to the development and maintenance of the ionic homeostasis in the brain [2].”
BackgroundHelms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
Self-citationElectrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study.
Butt, A. M., Jones, H. C., & Abbott, N. J. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018243 · Cited by 775 · cited 1×
“The average electrical resistivity of arterial microvessels was 1490 Ω·cm2, while, in venous vessels, a lower value of 918 Ω·cm2 was measured [37].”
BackgroundThe blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662 · cited 1×
“The leak can be modeled as a sort of parasitic shunt resistance, coupled parallelly with the actual resistance of the barrier layer [44].”
BackgroundElectrical resistance of brain microvascular endothelium
Crone, C., & Olesen, S. P. (1982) · Brain Research · doi:10.1016/0006-8993(82)91227-6 · Cited by 491 · cited 6×
“The first direct measurement of the electrical resistance of pial microvenules was performed on anesthetized frogs at room temperature [3].”
BackgroundMethodResultInfluentialMeasuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209 · cited 3×
“In addition, the mobile electrodes (chopstick or chamber) are not suitable to measure TEER in specifically designed microchannel systems [16].”
BackgroundMethodStebbins, M. J., Wilson, H. K., Canfield, S. G., Qian, T., Palecek, S. P., & Shusta, E. V. (2016) · Methods · doi:10.1016/j.ymeth.2015.10.016 · Cited by 179
Butt, A. M., & Jones, H. C. (1992) · Brain Research · doi:10.1016/0006-8993(92)90374-i · Cited by 106
Cited by
Yang, J., Luly, K. M., & Green, J. J. (2023) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1853 · Cited by 40
Sacharidou, A., Chambliss, K., Peng, J., Barrera, J., Tanigaki, K., Luby-Phelps, K., Özdemir, İ., Khan, S., Sirsi, S. R., Kim, S. H., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40562-w · Cited by 25
“…Aldrich) treated with 100ug/ ml collagen I (BD Bioscience), and transendothelial electrical resistance (TEER) was monitored daily for 4-6d until studies were performed using an epithelial volt-ohmmeter (EVOM, World Precision Instruments) to con fi rm the establishment of a con fl uent monolayer 51 .”
Measurement of Transendothelial Electrical Resistance in Blood-Brain Barrier Endothelial Cells
Waithe, O. Y., Peng, X., Childs, E. W., & Tharakan, B. (2024) · Methods in Molecular Biology · doi:10.1007/978-1-0716-3429-5_16 · Cited by 10
Use of the MicroSiM (µSiM) Barrier Tissue Platform for Modeling the Blood-Brain Barrier
McCloskey, M. C., Kasap, P., Trempel, M., Widom, L. P., Kuebel, J., Chen, K., Gaborski, T. R., Engelhardt, B., & McGrath, J. L. (2024) · Journal of Visualized Experiments · doi:10.3791/65258 · Cited by 8
Metadata
- Authors
- Vigh, J. P., Kincses, A., Ozgür, B., Walter, F. R., Santa-Maria, A. R., Valkai, S., Vastag, M., Neuhaus, W., Brodin, B., Dér, A., & Deli, M. A.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2021-06-11
- Volume
- 12
- Issue
- 6
- Pages
- 685
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W3168667198
- Cited by
- 127
- References
- 9
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.