Abstract
While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackson, J. D., & Levitt, L. C. (1962) · Physics Today · doi:10.1063/1.3057859 · Cited by 823
Centrifugal microfluidic platforms: advanced unit operations and applications
Strohmeier, O., Keller, M., Schwemmer, F., Zehnle, S., Mark, D., von Stetten, F., Zengerle, R., & Paust, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00371c · Cited by 463
Fabrication and characterization of electroosmotic micropumps
Zeng, S., Chen, C.-H., Mikkelsen, J. C., & Santiago, J. G. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00855-3 · Cited by 403
Compact and Highly Efficient Grating Couplers Between Optical Fiber and Nanophotonic Waveguides
Van Laere, F., Roelkens, G., Ayre, M., Schrauwen, J., Taillaert, D., Van Thourhout, D., Krauss, T. F., & Baets, R. (2007) · Journal of Lightwave Technology · doi:10.1109/jlt.2006.888164 · Cited by 373
Bridging the gap between optical fibers and silicon photonic integrated circuits
Zaoui, W. S., Kunze, A., Vogel, W., Berroth, M., Butschke, J., Letzkus, F., & Burghartz, J. (2014) · Optics Express · doi:10.1364/oe.22.001277 · Cited by 245
Sensitivity and Optimization of Localized Surface Plasmon Resonance Transducers
Kedem, O., Tesler, A. B., Vaskevich, A., & Rubinstein, I. (2011) · ACS Nano · doi:10.1021/nn102617d · Cited by 175
Puertas, S., Batalla, P., Moros, M., Polo, E., del Pino, P., Guisán, J. M., Grazú, V., & de la Fuente, J. M. (2011) · ACS Nano · doi:10.1021/nn200019s · Cited by 162
Highly-integrated lab-on-chip system for point-of-care multiparameter analysis
Schumacher, S., Nestler, J., Otto, T., Wegener, M., Ehrentreich-Förster, E., Michel, D., Wunderlich, K., Palzer, S., Sohn, K., Weber, A., et al. (2012) · Lab Chip · doi:10.1039/c1lc20693a · Cited by 148 · cited 1×
“The materials and manufacturing processes used for the microfluidic cartridge have been described elsewhere [7,8].”
MethodSelf-citationSuspended SOI waveguide with sub-wavelength grating cladding for mid-infrared
Soler Penadés, J., Alonso-Ramos, C., Khokhar, A. Z., Nedeljkovic, M., Boodhoo, L. A., Ortega-Moñux, A., Molina-Fernández, I., Cheben, P., & Mashanovich, G. Z. (2014) · Optics Letters · doi:10.1364/ol.39.005661 · Cited by 128
Jonsson, M. P., Jönsson, P., & Höök, F. (2008) · Analytical Chemistry · doi:10.1021/ac8008753 · Cited by 83
O’Brien, T., Johnson, L. H., III, Aldrich, J. L., Allen, S. G., Liang, L.-T., Plummer, A. L., Krak, S. J., & Boiarski, A. A. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00061-5 · Cited by 65 · cited 1×
“A change of matter on the ring resonator leads to a change in the refractive index, which changes the wavelength of the power peak’s appearance [21,22].”
BackgroundPolarization-Selective Coupling to Long-Range Surface Plasmon Polariton Waveguides
Mueller, J. P. B., Leósson, K., & Capasso, F. (2014) · Nano Letters · doi:10.1021/nl501860r · Cited by 54
Monolithic optofluidic ring resonator lasers created by femtosecond laser nanofabrication
Chandrahalim, H., Chen, Q., Said, A. A., Dugan, M. A., & Fan, X. (2015) · Lab on a Chip · doi:10.1039/c5lc00254k · Cited by 40
Leung, A., Shankar, P. M., & Mutharasan, R. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.10.056 · Cited by 39 · cited 1×
“A change of matter on the ring resonator leads to a change in the refractive index, which changes the wavelength of the power peak’s appearance [21,22].”
BackgroundOptofluidic Approaches for Enhanced Microsensor Performances
Testa, G., Persichetti, G., & Bernini, R. (2014) · Sensors · doi:10.3390/s150100465 · Cited by 35
Nestler, J., Morschhauser, A., Hiller, K., Otto, T., Bigot, S., Auerswald, J., Knapp, H. F., Gavillet, J., & Geßner, T. (2009) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-009-1948-4 · Cited by 32 · cited 1×
“The materials and manufacturing processes used for the microfluidic cartridge have been described elsewhere [7,8].”
MethodSelf-citationAbsolute Refractive Index Determination by Microinterferometric Backscatter Detection
Sørensen, H. S., Pranov, H. J., Larsen, N. B., Bornhop, D. J., & Andersen, P. E. (2003) · Analytical Chemistry · doi:10.1021/ac0206162 · Cited by 29
Polarization-selective elements with a substrate-mode grating pair structure
Huang, Y.-T., & Chen, Y.-H. (1993) · Optics Letters · doi:10.1364/ol.18.000921 · Cited by 23
März, A., Bocklitz, T. W., & Popp, J. (2011) · Analytical Chemistry · doi:10.1021/ac2015799 · Cited by 23
Research highlights: microfluidics and magnets
Pushkarsky, I., Tseng, P., Murray, C., & Carlo, D. D. (2014) · Lab on a Chip · doi:10.1039/c4lc90060j · Cited by 12
A multilayered integrated sensor for three-dimensional, micro total analysis systems
Xiao, J., Song, F., & Seo, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/9/095022 · Cited by 7
Misalignment-Tolerant Silicon Optical Modulator With Surface-Normal Optical Interface
Zhang, Z., Huang, B., Zhang, Z., Liu, H., Li, H., & Chen, H. (2015) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2015.2406733 · Cited by 6
TOWARDS AN IMPLANTABLE PULSED MODE ELECTROLYTIC DRUG DELIVERY SYSTEM
Yi, Y., Büttner, U., Foulds, I. G., & Arabia, S. (2013) · Cited by 5
Nanophotonic biosensors in silicon-on-insulator
Bienstman, P., Werquin, S., Arce, C. L., Witters, D., Puers, R., Lammertyn, J., Claes, T., Hallynck, E., Hoste, J.-W., & Martens, D. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6627335 · Cited by 3
A Photonic Biosensor for Space Applications (PBSA)
de Diego-Castilla, G., Pantoja, S. R., Geidel, S., Peransı́, S., Nestler, J., Martins, R., Sousa, A. M. L., Gómez‐Elvira, J., Moreno‐Paz, M., Cuesta, L. E., et al. (2015) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · Cited by 3
Self-citationON-CHIP PUMP SYSTEM FOR HIGH-PRESSURE MICROFLUIDIC APPLICATIONS
Ogden, S., Knaust, S., Dahlin, A. P., Hjort, K., & Bodén, R. (2013) · Cited by 1
Integration of Capillary Ring Resonator Biosensor with PDMS Microfluidics for Label-Free Biosensing
Farahi, F., & White, I. M. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-14998-6_78 · Cited by 1
Cited by
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Liao, Z., Zhang, Y., Li, Y., Miao, Y., Gao, S., Lin, F., Deng, Y., & Geng, L. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.032 · Cited by 236
Sengupta, J., & Hussain, C. M. (2020) · Carbon Trends · doi:10.1016/j.cartre.2020.100011 · Cited by 160
Cegielski, P. J., Giesecke, A. L., Neutzner, S., Porschatis, C., Gandini, M., Schall, D., Perini, C. A. R., Bolten, J., Suckow, S., Kataria, S., et al. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b02811 · Cited by 132
Metadata
- Authors
- Geidel, S., Peransi Llopis, S., Rodrigo, M., De Diego-Castilla, G., Sousa, A., Nestler, J., Otto, T., Gessner, T., & Parro, V.
- Affiliations
- Fraunhofer Institute for Electronic Nano Systems (DE)
- DAS Photonics S.L., Valencia 46022, Spain
- Centro de Astrobiología (INTA-CSIC), Torrejon de Ardoz 28850, Spain
- Evoleo Technologies Lda, 442565 Maia, Portugal
- Berlin Institute for the Foundations of Learning and Data (DE)
- Corresponding author
- Geidel, Sascha
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2016-09-13
- Volume
- 7
- Issue
- 9
- Pages
- 153
- ISSN
- 2072-666X (ISSN-L)
- PMC
- PMC6189757
- OpenAlex
- W2518754193
- Cited by
- 26
- References
- 27
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 1
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Micromachines (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Funders
- European Commission (312942-PBSA)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- microfluidic cartridge, immunoassay, protein detection, biofunctionalization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.