CoChat

l-DNA-Based Catalytic Hairpin Assembly Circuit

Open access

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index; 3 of the 7 sources its claims cite were checked for support.

Abstract

Isothermal, enzyme-free amplification methods based on DNA strand-displacement reactions show great promise for applications in biosensing and disease diagnostics but operating such systems within biological environments remains extremely challenging due to the susceptibility of DNA to nuclease degradation. Here, we report a catalytic hairpin assembly (CHA) circuit constructed from nuclease-resistant l-DNA that is capable of unimpeded signal amplification in the presence of 10% fetal bovine serum (FBS). The superior biostability of the l-DNA CHA circuit relative to its native d-DNA counterpart was clearly demonstrated through a direct comparison of the two systems (d versus l) under various conditions. Importantly, we show that the l-CHA circuit can be sequence-specifically interfaced with an endogenous d-nucleic acid biomarker via an achiral peptide nucleic acid (PNA) intermediary, enabling catalytic detection of the target in FBS. Overall, this work establishes a blueprint for the detection of low-abundance nucleic acids in harsh biological environments and provides further impetus for the construction of DNA nanotechnology using l-oligonucleotides.

Overview

CoChat Summary

TL;DR

The paper reports the first catalytic hairpin assembly (CHA) circuit built entirely from nuclease-resistant l-DNA, which amplifies signal in 10% fetal bovine serum where its d-DNA counterpart fails. It also interfaces the l-CHA circuit with a d-RNA biomarker, miR-155, through an achiral PNA inversion gate.

Key findings

  • The l-DNA CHA circuit operated similarly to the d-DNA version but with a reduced initial rate: 24.78 ± 1.0 min−1 for l-CHA versus 54.02 ± 2.64 min−1 for d-CHA at 200 nM initiator.
  • With 2 nM initiator (100-fold below hairpins/reporter), d-CHA reached 40% maximal fluorescence after 3 h (~20-fold amplification), while l-CHA reached ~20% maximal fluorescence (~10-fold amplification).
  • In 10% FBS, the d-CHA circuit degraded during a 2 h pre-incubation, showed initiator-independent leak, and failed to amplify; the l-CHA circuit remained intact and gave a concentration-dependent response, again reaching ~20% maximal signal with 2 nM l-OUT155 after 3 h.
  • The full heterochiral circuit detected d-miR-155 with modest ~3–5-fold amplification, discriminated against single- and double-mismatch inputs, and in 10% FBS produced ~3-fold amplification with 20 nM l-miR-155, though with higher background.

Methods

  • CHA hairpins H1 and H2 were designed by varying complementary domains 4–6 following Ellington-derived principles, optimized first as d-DNA and monitored by native PAGE; l-DNA versions were then synthesized and purified.
  • Fluorescence CHA reactions contained 200 nM each H1, H2, and reporter R, with or without 200 nM inversion gate A155, in 50 mM KCl, 20 mM NaCl, 1 mM MgCl2, 25 mM TRIS pH 7.6, at 37 °C; reactions were pre-incubated 2 h, then initiator was added and monitored for 3 h using Cy3 excitation/emission at 520/580–640 nm.
  • Heterochiral strand-displacement and CHA reactions were also analyzed by 20% native PAGE; duplex components were assembled by hybridization titration to achieve 1:1 strand ratios.

Limitations

  • The paper states that the l-CHA rate was somewhat reduced relative to d-CHA and attributes this to possible differences in oligonucleotide quality, pipetting, and concentration errors.
  • The paper states that the full heterochiral circuit in 10% FBS had reduced sensitivity due to higher background, possibly from leakage between the inversion gate and l-H1, and that further optimization is needed.
  • Evident from the text: the work tests only 10% FBS, not living cells; mismatch discrimination is shown only within the toehold domain; and in serum the full circuit used l-miR-155 rather than native d-miR-155 to avoid nuclease degradation before activation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/molecules25040947

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 (a) Three types of nucleic acids used in this work. d-DNA (black), l-DNA (blue), and peptide nucleic acid (PNA) (green) are distinguished by color throughout the text; (b) Inversion Gate. The toehold domain (t*) resides on the achiral PNA strand in the l-DNA/PNA heteroduplex (Inversion Gate). Therefore, the d-input can still bind to the inversion gate (via t and t*) and displace l-OUT. In this way, the sequence information in domain (a) has become inverted.
Figure 1 (a) Three types of nucleic acids used in this work. d-DNA (black), l-DNA (blue), and peptide nucleic acid (PNA) (green) are distinguished by color throughout the text; (b) Inversion Gate. The toehold domain (t*) resides on the achiral PNA strand in the l-DNA/PNA heteroduplex (Inversion Gate). Therefore, the d-input can still bind to the inversion gate (via t and t*) and displace l-OUT. In this way, the sequence information in domain (a) has become inverted.CC BY · PubMed Central
Figure 2 Schematic illustration of the heterochiral l-CHA circuit. Sequences of all strands are listed in Table S1. d-MiR-155 RNA is colored red.
Figure 2 Schematic illustration of the heterochiral l-CHA circuit. Sequences of all strands are listed in Table S1. d-MiR-155 RNA is colored red.CC BY · PubMed Central
Figure 3 Fluorescence monitoring (Cy3) of CHA reactions in the absence (a,b) and presence (c,d) of 10% fetal bovine serum (FBS). All reaction mixtures contained 200 nM hairpins (H1 and H2) and 200 nM reporter complex (R) in the indicated stereochemistry, along with either 0% or 10% FBS, 50 mM KCl, 20 mM NaCl, 1 mM MgCl2, and 25 mM TRIS (pH 7.6). Reactions were initiated with the indicated concentration of either d- or l-OUT155 and were carried out at 37 °C. CHA reactions initiated with a scrambled input OUTs (200 nM) are indicated by dotted lines. Fluorescence (Fluor.) in all figures is reported in units such that 0.0 and 1.0 are the fluorescence of the quenched and activated reporter complex, respectively, at 200 nM. Average fluorescence data from triplicate experiments is plotted.
Figure 3 Fluorescence monitoring (Cy3) of CHA reactions in the absence (a,b) and presence (c,d) of 10% fetal bovine serum (FBS). All reaction mixtures contained 200 nM hairpins (H1 and H2) and 200 nM reporter complex (R) in the indicated stereochemistry, along with either 0% or 10% FBS, 50 mM KCl, 20 mM NaCl, 1 mM MgCl2, and 25 mM TRIS (pH 7.6). Reactions were initiated with the indicated concentration of either d- or l-OUT155 and were carried out at 37 °C. CHA reactions initiated with a scrambled input OUTs (200 nM) are indicated by dotted lines. Fluorescence (Fluor.) in all figures is reported in units such that 0.0 and 1.0 are the fluorescence of the quenched and activated reporter complex, respectively, at 200 nM. Average fluorescence data from triplicate experiments is plotted.CC BY · PubMed Central
Figure 4 Fluorescence monitoring (Cy3) of the full heterochiral CHA circuit in the absence (a,c) and presence (b,d) of 10% FBS. Reaction conditions are identical to those described in Figure 3, except that 200 nM inversion gate A155 was also included. Reactions were initiated with the indicated concentration of either d- or l-miR-155 as indicated and were carried out at 37 °C. Average fluorescence data from triplicate experiments is plotted.
Figure 4 Fluorescence monitoring (Cy3) of the full heterochiral CHA circuit in the absence (a,c) and presence (b,d) of 10% FBS. Reaction conditions are identical to those described in Figure 3, except that 200 nM inversion gate A155 was also included. Reactions were initiated with the indicated concentration of either d- or l-miR-155 as indicated and were carried out at 37 °C. Average fluorescence data from triplicate experiments is plotted.CC BY · PubMed Central
Figure 5 Mismatch discrimination by the full heterochiral CHA circuit. Reaction conditions are identical to those described in Figure 4. Reactions were initiated with either 20 nM input (solid lines) or 200 nM input (dotted lines) and were carried out at 37 °C.
Figure 5 Mismatch discrimination by the full heterochiral CHA circuit. Reaction conditions are identical to those described in Figure 4. Reactions were initiated with either 20 nM input (solid lines) or 200 nM input (dotted lines) and were carried out at 37 °C.CC BY · PubMed Central

Verification

Claims the paper makes

3 Valid · 0 Not valid · 3 Not checked · 29 Own results and interpretations

15 more claims

Create a free account to see all 35 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 14
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 33 references

Cited by

Metadata

Authors
Kabza, A. M., & Sczepanski, J. T.
Affiliations
Texas A&M University (US)
Corresponding author
Sczepanski, Jonathan T.
Venue
Molecules
Publisher
MDPI AG
Published
2020-02-20
Volume
25
Issue
4
Pages
947
ISSN
1420-3049 (ISSN-L)
OpenAlex
W3007783347
Cited by
26
References
34
Citations by year
2026: 4 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 8 · 2020: 1
FWCI
1.30
Type
journal article
Language
en
Open access
Locations
  • Molecules (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Institutes of Health (R21EB027855, R35GM124974)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › DNA and Nucleic Acid Chemistry
  • Physical Sciences › Mathematics › Theoretical Computer Science › DNA and Biological Computing
Keywords
L-DNA, catalytic hairpin assembly, DNA strand displacement, enzyme-free amplification, nuclease resistance, peptide nucleic acid, sequence-specific detection, fetal bovine serum, DNA nanotechnology, biosensing
MeSH terms
Nucleic Acid Conformation, Nucleic Acid Hybridization, Oligonucleotides, Biosensing Techniques, DNA, Catalytic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.