CoChat

Full Parametric Study of the Influence of Ionomer Content, Catalyst Loading and Catalyst Type on Oxygen and Ion Transport in PEM Fuel Cell Catalyst Layers

Open access

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index; 1 of the 2 sources its claims cite were checked for support.

Abstract

This study investigates the influence of ionomer content, catalyst loading and catalyst type on oxygen and ion transport in PEM fuel cell catalyst layers.

Overview

CoChat Summary

## TL;DR

This paper reports a full parametric study of cathode catalyst layers in PEM fuel cells, varying ionomer content, Pt loading, and catalyst type (40 wt.% and 60 wt.% Pt/C) to see how oxygen and ion transport affect performance. The key result is that the optimum ionomer content depends on operating point, humidity, loading, and catalyst type, with thicker/high-loading layers increasingly limited by through-plane diffusion and proton transport.

## Key findings

  • The study varied ionomer content from 15 to 50 wt.% in dry layers, corresponding to an I/C ratio of 0.29–1.67, and Pt loading from 0.05–0.8 mg cm−2 for 40 wt.% Pt/C and 60 wt.% Pt/C catalysts.
  • SEM/EDX showed no obvious interfaces between printed sublayers and a homogeneous distribution of Pt, C, and F; the authors conclude that electrical and protonic contact is established regardless of printing multiple layers.
  • The HFR during polarization curves was in a low and narrow range of 25–35 mOhm cm2, indicating stable production/characterization and little influence from membrane-property variation.
  • For the 40 wt.% catalyst, the optimum ionomer content depended on conditions: at low current density the optimum was around I/C = 0.71–1.36 for Pt loadings > 0.3 mg cm−2; at 30% RH the optimum was 1.36, while at 120% RH it was 0.62–1.36. At 300 mV, the optimum Pt loading was around 0.25 mg cm−2; for the 60 wt.% catalyst it was around 0.3 mg cm−2.
  • The paper concludes that through-plane diffusion losses become more limiting than proton conductivity at high Pt loading and high ionomer content, and that the general trends are similar for 40 and 60 wt.% Pt/C, though the 60 wt.% catalyst needs less ionomer because its catalyst layer is thinner.

## Methods

  • Design: Full parametric study of cathode catalyst layers, varying ionomer content, Pt loading, and catalyst type (40 wt.% Pt/C and 60 wt.% Pt/C) in membrane electrode assemblies.
  • Sample/data: Catalyst-coated membranes were made by screen printing; ionomer content was 15–50 wt.% in dry layers, with I/C = 0.29–1.67 and Pt loading = 0.05–0.8 mg cm−2. The authors say they discussed “80+ cells” in the analysis.
  • Main analysis: Ex situ SEM/EDX for morphology and layer uniformity; in situ polarization curves, high-frequency resistance (HFR), cyclic voltammetry for ECSA, and humidity sweeps at 1 A/cm2 under varied relative humidity.

## Limitations

  • The authors explicitly note that the paper provides a data set as a starting point for further work, and say they plan future studies on graded catalyst layers, limiting current density, impedance spectroscopy, and accelerated stress tests; this indicates the present study does not address those topics.
  • The paper states that some comparisons are based on selected points/conditions from the polarization curves and that some data are “not shown” for all ionomer contents; this suggests the reported analysis is not exhaustive for every measured condition.
  • The paper does not report a formal statistical uncertainty analysis or error bars for the key optimum values in the provided text, so the strength of those optima is not fully quantified here.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/molecules25071523

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 SEM images of three catalyst layers with an ionomer content of 30 wt.% and a platinum loading of (a) 0.08 mg cm−2 (1 Layer), (b) 0.180 mg cm−2 (2 Layers) and (c) 0.271 mg cm−2 (3 Layers) with the corresponding carbon, fluorine and platinum distributions given in (d) 1 layer, (e) 2 layers and (f) 3 layers: red corresponds to carbon, green corresponds to fluorine and turquoise to platinum.
Figure 1 SEM images of three catalyst layers with an ionomer content of 30 wt.% and a platinum loading of (a) 0.08 mg cm−2 (1 Layer), (b) 0.180 mg cm−2 (2 Layers) and (c) 0.271 mg cm−2 (3 Layers) with the corresponding carbon, fluorine and platinum distributions given in (d) 1 layer, (e) 2 layers and (f) 3 layers: red corresponds to carbon, green corresponds to fluorine and turquoise to platinum.CC BY · PubMed Central
Figure 2 Dependence of catalyst layer thickness for the 40 wt% catalyst. (a) Measured thickness with an ionomer content of 35 wt.% dependent on the platinum loading, (b) effect of ionomer content on the thickness of the catalyst layer with Pt loading of 0.40 mg/cm2.
Figure 2 Dependence of catalyst layer thickness for the 40 wt% catalyst. (a) Measured thickness with an ionomer content of 35 wt.% dependent on the platinum loading, (b) effect of ionomer content on the thickness of the catalyst layer with Pt loading of 0.40 mg/cm2.CC BY · PubMed Central
Figure 3 Polarization curves with varying Pt loading and I/C ratio under (a) wet conditions, (b) dry conditions to illustrate the reproducibility of the production method and characterization technique with their corresponding high frequency resistance under (c) wet conditions and (d) dry conditions.
Figure 3 Polarization curves with varying Pt loading and I/C ratio under (a) wet conditions, (b) dry conditions to illustrate the reproducibility of the production method and characterization technique with their corresponding high frequency resistance under (c) wet conditions and (d) dry conditions.CC BY · PubMed Central
Figure 4 Electrochemical active surface area, ECSA, of the different catalyst coated membranes, CCMs, produced with 40wt% Pt/C, dependent on platinum loading and ionomer content.
Figure 4 Electrochemical active surface area, ECSA, of the different catalyst coated membranes, CCMs, produced with 40wt% Pt/C, dependent on platinum loading and ionomer content.CC BY · PubMed Central
Figure 5 The current density dependency on the Pt loading and I/C ratio at cell voltages of (a) 900 mV, (b) 700 mV and (c) 300 mV for a catalyst of 40 wt% Pt/C.
Figure 5 The current density dependency on the Pt loading and I/C ratio at cell voltages of (a) 900 mV, (b) 700 mV and (c) 300 mV for a catalyst of 40 wt% Pt/C.CC BY · PubMed Central
Figure 6 The current density dependency on the Pt loading and ionomer content at cell voltages of (a) 900 mV, (b) 700 mV and (c) 300 mV for a catalyst of 60 wt% Pt/C.
Figure 6 The current density dependency on the Pt loading and ionomer content at cell voltages of (a) 900 mV, (b) 700 mV and (c) 300 mV for a catalyst of 60 wt% Pt/C.CC BY · PubMed Central
Figure 7 Relative humidity sweeps dependent on I/C ratio for Pt/C 40wt.% and a Pt loading of 0.25 mg cm−2 at a current density of 1.0 A cm−2.
Figure 7 Relative humidity sweeps dependent on I/C ratio for Pt/C 40wt.% and a Pt loading of 0.25 mg cm−2 at a current density of 1.0 A cm−2.CC BY · PubMed Central
Figure 8 The cell voltage dependent on Pt loading and I/C ratio for a relative humidity of (a) 30% and (b) 120% for Pt/C of 40wt.% and a relative humidity of (c) 30% and (d) 120% for Pt/C of 60wt.%. All humidity sweeps are carried out at a current density of 1.0 A cm−2.
Figure 8 The cell voltage dependent on Pt loading and I/C ratio for a relative humidity of (a) 30% and (b) 120% for Pt/C of 40wt.% and a relative humidity of (c) 30% and (d) 120% for Pt/C of 60wt.%. All humidity sweeps are carried out at a current density of 1.0 A cm−2.CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 0 Not valid · 2 Not checked · 57 Own results and interpretations

38 more claims

Create a free account to see all 60 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 2
  • It may state two separate claims as one. 17

Create a free account to see these claims.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Alink, R., Singh, R., Schneider, P., Christmann, K., Schall, J., Keding, R., & Zamel, N.
Affiliations
Fraunhofer Institute for Solar Energy Systems (DE)
Corresponding author
Zamel, Nada
Venue
Molecules
Publisher
MDPI AG
Published
2020-03-27
Volume
25
Issue
7
Pages
1523
ISSN
1420-3049 (ISSN-L)
OpenAlex
W3013228126
Cited by
77
References
21
Citations by year
2026: 14 · 2025: 18 · 2024: 12 · 2023: 14 · 2022: 11 · 2021: 8
FWCI
2.83
Type
journal article
Language
en
Open access
Locations
  • Molecules (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion, other-oa)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion, cc-by)
Funders
Bundesministerium für Bildung und Forschung (03SF0544A)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
  • Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
Keywords
proton exchange membrane fuel cells, cathode catalyst layer, ionomer content, catalyst loading, platinum catalysts, oxygen transport, ion transport, membrane electrode assembly, high surface area carbon, parametric study
MeSH terms
Carbon, Catalysis, Electrochemistry, Electrodes, Electrolytes, Ions, Membranes, Artificial, Microscopy, Electron, Scanning, Oxygen, Platinum, Polymers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.