Dry Powder for Pulmonary Delivery: A Comprehensive Review
Open accessThe DOI matches its Crossref record; 139 of the 139 references it cites were found in a registry or an index.
Abstract
The pulmonary route has long been used for drug administration for both local and systemic treatment. It possesses several advantages, which can be categorized into physiological, i.e., large surface area, thin epithelial membrane, highly vascularized, limited enzymatic activity, and patient convenience, i.e., non-invasive, self-administration over oral and systemic routes of drug administration. However, the formulation of dry powder for pulmonary delivery is often challenging due to restrictions on aerodynamic size and the lung’s lower tolerance capacity in comparison with an oral route of drug administration. Various physicochemical properties of dry powder play a major role in the aerosolization, deposition, and clearance along the respiratory tract. To prepare suitable particles with optimal physicochemical properties for inhalation, various manufacturing methods have been established. The most frequently used industrial methods are milling and spray-drying, while several other alternative methods such as spray-freeze-drying, supercritical fluid, non-wetting templates, inkjet-printing, thin-film freezing, and hot-melt extrusion methods are also utilized. The aim of this review is to provide an overview of the respiratory tract structure, particle deposition patterns, and possible drug-clearance mechanisms from the lungs. This review also includes the physicochemical properties of dry powder, various techniques used for the preparation of dry powders, and factors affecting the clinical efficacy, as well as various challenges that need to be addressed in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inhaler mishandling remains common in real life and is associated with reduced disease control
Melani, A. S., Bonavia, M., Cilenti, V., Cinti, C., Lodi, M., Martucci, P., Serra, M., Scichilone, N., Sestini, P., Aliani, M., et al. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.005 · Cited by 947
What the pulmonary specialist should know about the new inhalation therapies
Laube, B. L., Janssens, H. M., de Jongh, F. H. C., Devadason, S. G., Dhand, R., Diot, P., Everard, M. L., Horvath, I., Navalesi, P., Voshaar, T., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00166410 · Cited by 806
Formulation strategy and use of excipients in pulmonary drug delivery
Pilcer, G., & Amighi, K. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.03.017 · Cited by 791
MICROENCAPSULATION BY SPRAY DRYING
I Ré, M. (1998) · Drying Technology · doi:10.1080/07373939808917460 · Cited by 711
Inhaled nanoparticles—A current review
Yang, W., Peters, J. I., & Williams, R. O. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.02.011 · Cited by 666 · cited 1×
“5μm are exhaled out during exhalation [1,32].”
Particle Engineering for Pulmonary Drug Delivery
Chow, A. H. L., Tong, H. H. Y., Chattopadhyay, P., & Shekunov, B. Y. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9174-3 · Cited by 645 · cited 4×
“have a rough surface, and have high levels of electrostatic charge on the surface [90,91].”
BackgroundInfluentialNanoparticles for drug delivery to the lungs
Sung, J. C., Pulliam, B. L., & Edwards, D. A. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.09.005 · Cited by 643
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578 · cited 1×
“Approximately 50–60% of delivered particulate matters are deposited into the pharyngeal cavity [33] and may cause local or systemic adverse effects.”
BackgroundDry Powder Inhaler Formulation
Telko, M. J., & Hickey, A. J. (2005) · Respiratory Care · doi:10.4187/respcare.05501209 · Cited by 498
Modelling inhaled particle deposition in the human lung—A review
Hofmann, W. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.007 · Cited by 492 · cited 2×
“minor rates of deposition include interception and electrostatic precipitation [28].”
Background
Cited by
Pharmaceutical strategies to extend pulmonary exposure of inhaled medicines
Guo, Y., Bera, H., Shi, C., Zhang, L., Cun, D., & Yang, M. (2021) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2021.05.015 · Cited by 169
Metadata
- Authors
- Chaurasiya, B., & Zhao, Y.-Y.
- Venue
- Pharmaceutics
- Publisher
- MDPI AG
- Published
- 2020-12-28
- Volume
- 13
- Issue
- 1
- Pages
- 31
- ISSN
- 1999-4923 (ISSN-L)
- OpenAlex
- W3114518749
- Cited by
- 241
- References
- 139
- FWCI
- 11.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.