Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification
Open accessThe DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
Abstract
Various frameworks and methods, such as quality by design (QbD), real time release test (RTRT), and continuous process verification (CPV), have been introduced to improve drug product quality in the pharmaceutical industry. The methods recognize that an appropriate combination of process controls and predefined material attributes and intermediate quality attributes (IQAs) during processing may provide greater assurance of product quality than end-product testing. The efficient analysis method to monitor the relationship between process and quality should be used. Process analytical technology (PAT) was introduced to analyze IQAs during the process of establishing regulatory specifications and facilitating continuous manufacturing improvement. Although PAT was introduced in the pharmaceutical industry in the early 21st century, new PAT tools have been introduced during the last 20 years. In this review, we present the recent pharmaceutical PAT tools and their application in pharmaceutical unit operations. Based on unit operations, the significant IQAs monitored by PAT are presented to establish a control strategy for CPV and real time release testing (RTRT). In addition, the equipment type used in unit operation, PAT tools, multivariate statistical tools, and mathematical preprocessing are introduced, along with relevant literature. This review suggests that various PAT tools are rapidly advancing, and various IQAs are efficiently and precisely monitored in the pharmaceutical industry. Therefore, PAT could be a fundamental tool for the present QbD and CPV to improve drug product quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principal component analysis: A review and recent developments
Jolliffe, I. T., & Cadima, J. (2016) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2015.0202 · Cited by 10,117 · cited 1×
“PAT in CPV ensures product quality throughout the manufacturing process and enables the automation of transportation between product processes [16,17].”
BackgroundReview of the most common pre-processing techniques for near-infrared spectra
Rinnan, Å., Berg, F. V. D., & Engelsen, S. B. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.07.007 · Cited by 3,057
Nucleation, growth and breakage phenomena in agitated wet granulation processes: a review
Iveson, S. M., Litster, J. D., Hapgood, K., & Ennis, B. J. (2001) · Powder Technology · doi:10.1016/s0032-5910(01)00313-8 · Cited by 1,297
Design of Freeze-Drying Processes for Pharmaceuticals: Practical Advice
Tang, X., & Pikal, M. J. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000016234.73023.75 · Cited by 972
NIR spectroscopy: a rapid-response analytical tool
Blanco, M., & Villarroya, I. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00404-1 · Cited by 874 · cited 25×
“Based on the correlation between CQAs, CPPs, and IQAs, process and quality control are possible by checking process variability in real-time through PAT during the commercial-/pilot-scale manufacturing process.”
BackgroundMethodInfluentialNear-infrared spectroscopy and imaging: Basic principles and pharmaceutical applications
REICH, G. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.020 · Cited by 849 · cited 20×
“There are various approaches, such as in-process testing, RTRT, and finished product testing [11,14,15].”
MethodInfluentialSpray Drying Technique. I: Hardware and Process Parameters
Cal, K., & Sollohub, K. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21886 · Cited by 402
Significance of controlling crystallization mechanisms and kinetics in pharmaceutical systems
Rodríguez‐hornedo, N., & Murphy, D. (1999) · Journal of Pharmaceutical Sciences · doi:10.1021/js980490h · Cited by 371
Cronin, M. T. D., & Schultz, T. W. (2003) · Journal of Molecular Structure: THEOCHEM · doi:10.1016/s0166-1280(02)00616-4 · Cited by 350
Roll compaction/dry granulation: pharmaceutical applications
Kleinebudde, P. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.04.014 · Cited by 282
Næs, T., & Martens, H. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020207 · Cited by 230 · cited 1×
“By applying the PLS calibration model to predict tablet characteristics, the authors suggested that the polymer concentration of the coating suspension, which is a CPP, affects CQAs [4].”
MethodMultivariate data analysis applied to spectroscopy: Potential application to juice and fruit quality
Cozzolino, D., Cynkar, W. U., Shah, N., & Smith, P. (2011) · Food Research International · doi:10.1016/j.foodres.2011.01.041 · Cited by 227
Santos, D., Maurício, A. C., Sencadas, V., Santos, J. D., Fernandes, M. H., & Gomes, P. S. (2018) · InTech eBooks · doi:10.5772/intechopen.72247 · Cited by 227 · cited 1×
“Thousands of code lengths are measured simultaneously, and based on this, a code-length distribution can be generated to measure particle properties such as particle size and size distribution in real-time [92,93,95].”
BackgroundNear‐infrared spectroscopy and imaging for the monitoring of powder blend homogeneity
El‐Hagrasy, A. S., Morris, H. R., D'Amico, F., Lodder, R. A., & Drennen, J. K. (2001) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.1082 · Cited by 191
De Beer, T. R. M., Vercruysse, P., Burggraeve, A., Quinten, T., Ouyang, J., Zhang, X., Vervaet, C., Remon, J. P., & Baeyens, W. R. G. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21633 · Cited by 190
The effect of processing parameters on pharmaceutical tablet properties
Sinka, I. C., Motazedian, F., Cocks, A. C. F., & Pitt, K. G. (2009) · Powder Technology · doi:10.1016/j.powtec.2008.04.020 · Cited by 167
De Beer, T. R. M., Bodson, C., Dejaegher, B., Walczak, B., Vercruysse, P., Burggraeve, A., Lemos, A., Delattre, L., Heyden, Y. V., Remon, J. P., et al. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.07.023 · Cited by 166 · cited 7×
“It can analyze the IQAs and CQAs of drug content [160–162] during the blending process, moisture content [8,9] during the drying and granulation process, and coating thickness and content [157,163,164] during the coating process, as well as enable polymorph identification in API preparation [165–167], granuleformulati…”
MethodInfluentialPreparation, evaluation and optimization of rapidly disintegrating tablets
Sunada, H., & Bi, Y. (2002) · Powder Technology · doi:10.1016/s0032-5910(01)00415-6 · Cited by 166
Greaves, D., Boxall, J., Mulligan, J., Montesi, A., Creek, J., Dendy Sloan, E., & Koh, C. A. (2008) · Chemical Engineering Science · doi:10.1016/j.ces.2008.07.023 · Cited by 166
Quality by Design (QbD) : A new concept for development of quality pharmaceuticals
Patil, A. S., & Pethe, A. M. (2013) · International Journal of Pharmaceutical Quality Assurance · doi:10.25258/ijpqa.4.2.1 · Cited by 156 · cited 1×
“The QbD approach has been introduced to overcome this and to improve understanding of product performance, identify critical process parameters (CPPs) during quality risk assessment of the product manufacturing process, and establish appropriate control strategies for each variable [13,22].”
MethodCritical review of near-infrared spectroscopic methods validations in pharmaceutical applications
Bleye, C. D., Chavez, P.-F., Mantanus, J., Marini, R. D., Hubert, P., Rozet, E., & Ziémons, E. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.02.003 · Cited by 148
Sekulic, S. S., Wakeman, J., Doherty, P., & Hailey, P. A. (1998) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00025-9 · Cited by 148
Application of chemometric methods to XRF-data – A tutorial review
Владимирович, П. В., Yaroshenko, I., Legin, A. V., Semenov, V. G., & Kirsanov, D. O. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.023 · Cited by 147 · cited 27×
“PAT in CPV ensures product quality throughout the manufacturing process and enables the automation of transportation between product processes [16,17].”
BackgroundMethodInfluentialWet Granulation in a Twin‐Screw Extruder: Implications of Screw Design
Thompson, M. R., & Sun, J. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21973 · Cited by 143
Beer, T. R. M. D., Allesø, M., Goethals, F., Coppens, A., Heyden, Y. V., de Diego, H. L., Rantanen, J., Verpoort, F., Vervaet, C., Remon, J. P., et al. (2007) · Analytical Chemistry · doi:10.1021/ac070549h · Cited by 141
Adam, S., Suzzi, D., Radeke, C. A., & Khinast, J. (2010) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2010.10.013 · Cited by 139
Chemometrics in bioprocess engineering: Process analytical technology (PAT) applications
Lopes, J. A., Costa, P. F., Alves, T. P., & Menezes, J. C. (2004) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.07.006 · Cited by 137 · cited 1×
“For example, it is common to use control charts for monitoring general production processes, thereby ensuring that various aspects of the production process are controlled [5,6].”
BackgroundGalata, D. L., Könyves, Z., Nagy, B., Novák, M., Mészáros, L. A., Szabó, E., Farkas, A., Marosi, G., & Nagy, Z. K. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120338 · Cited by 136
Kourti, T. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0303-y · Cited by 134 · cited 4×
“Most parts of the coating process are performed in pans or fluidized-bed devices [1,256].”
BackgroundMethodInfluentialAndersson, M., Folestad, S., Gottfries, J., Johansson, M. O., Josefson, M., & Wahlund, K. (2000) · Analytical Chemistry · doi:10.1021/ac990256r · Cited by 132
Real-time assessment of critical quality attributes of a continuous granulation process
Fonteyne, M., Vercruysse, J., Córdoba-Díaz, D., Gildemyn, D., Vervaet, C., Remon, J. P., & Beer, T. D. (2011) · Pharmaceutical Development and Technology · doi:10.3109/10837450.2011.627869 · Cited by 127
Gnoth, S., Jenzsch, M., Simutis, R., & Lübbert, A. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.03.020 · Cited by 127 · cited 1×
“The US Food and Drug Administration (FDA)’s Center for Drug Evaluation and Research (CDER) discussed the need for FDA guidance to facilitate PAT implementation, and the FDA published the PAT guidance for innovative pharmaceutical manufacturing and quality in September 2004 [10].”
BackgroundDhenge, R. M., Washino, K., Cartwright, J. J., Hounslow, M. J., & Salman, A. D. (2012) · Powder Technology · doi:10.1016/j.powtec.2012.05.045 · Cited by 125
Järvinen, K., Hoehe, W., Järvinen, M. A., Poutiainen, S., Juuti, M., & Borchert, S. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2012.12.032 · Cited by 124
Near-infrared spectroscopic characterization of pharmaceutical powder blends
Wargo, D. J., & Drennen, J. K. (1996) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(96)01739-6 · Cited by 122
Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing
Jiang, M., Severson, K. A., Love, J. C., Madden, H., Swann, P., Zang, L., & Braatz, R. D. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26383 · Cited by 118
Nagy, B., Farkas, A., Gyürkés, M., Komaromy-Hiller, S., Démuth, B., Szabó, B., Nusser, D., Borbás, E., Marosi, G., & Nagy, Z. K. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.07.041 · Cited by 113
Riippi, M., Antikainen, O. K., Niskanen, T., & Yliruusi, J. K. (1998) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(98)00043-5 · Cited by 111
PAT for tableting: Inline monitoring of API and excipients via NIR spectroscopy
Wahl, P. R., Fruhmann, G., Sacher, S., Straka, G., Sowiński, S., & Khinast, J. (2014) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2014.03.021 · Cited by 110
A correlation principal component regression analysis of NIR data
Sun, J. (1995) · Journal of Chemometrics · doi:10.1002/cem.1180090104 · Cited by 109
Eliasson, C., Macleod, N. A., Jayes, L., Clarke, F. C., Hammond, S. V., Smith, M. R., & Matousek, P. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.01.013 · Cited by 107
Analytical Techniques in the Pharmaceutical Sciences
Rades, T., Perrie, Y., & Müllertz, A. (2016) · Advances in delivery science and technology · doi:10.1007/978-1-4939-4029-5 · Cited by 107
Shi, Z., Cogdill, R. P., Short, S., & Anderson, C. A. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.03.013 · Cited by 107
Lee, M., Seo, D.-Y., Lee, H.-E., Wang, I.-C., Kim, W., Jeong, M.-Y., & Choi, G. J. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.10.022 · Cited by 107
PAT-tools for process control in pharmaceutical film coating applications
Knop, K., & Kleinebudde, P. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.01.062 · Cited by 105
On-line monitoring of a granulation process by NIR spectroscopy
Alcalà, M., Blanco, M., Bautista, M., & González, J. M. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21818 · Cited by 104
In-line monitoring of a pharmaceutical blending process using FT-Raman spectroscopy
Vergote, G. J., Beer, T. R. M. D., Vervaet, C., Remon, J. P., Baeyens, W. R. G., Diericx, N., & Verpoort, F. (2004) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2003.11.005 · Cited by 102
Lin, H., Dong, Y., Markl, D., Williams, B. M., Zheng, Y., Shen, Y., & Zeitler, J. A. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.12.012 · Cited by 100
A rapid quantitative assay of intact paracetamol tablets by reflectance near-infrared spectroscopy
Trafford, A. D., Jee, R. D., Moffat, A. C., & Graham, P. (1999) · The Analyst · doi:10.1039/a806629i · Cited by 100
A quality by design study applied to an industrial pharmaceutical fluid bed granulation
Lourenço, V., Lochmann, D., Reich, G., et al. (2012) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2012.03.003 · Cited by 99 · cited 1×
“This study shows that, when two PAT tools are used simultaneously, they can be mutually verified, and thus, higher accuracy can be provided [59].”
MethodHo, L., Müller, R., Gordon, K. C., Kleinebudde, P., Pepper, M., Rades, T., Shen, Y., Taday, P. F., & Zeitler, J. A. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.002 · Cited by 98
Karande, A. D., Heng, P. W. S., & Liew, C. V. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.06.011 · Cited by 97
Findlay, W. P., Peck, G. E., & Morris, K. R. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20276 · Cited by 96
Dependence of ejection force on tableting speed—A compaction simulation study
Sun, C. C. (2015) · Powder Technology · doi:10.1016/j.powtec.2015.04.004 · Cited by 95
Process analytical technology for continuous manufacturing tableting processing: A case study
Pauli, V., Roggo, Y., Pellegatti, L., Nguyen‐Trung, N. Q., Elbaz, F., Enßlin, S., Kleinebudde, P., & Krumme, M. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.09.016 · Cited by 93
Leersnyder, F. D., Peeters, E., Djalabi, H., Vanhoorne, V., Snick, B. V., Hong, K., Hammond, S. V., Liu, A. Y., Ziémons, E., Vervaet, C., et al. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.01.032 · Cited by 91
Peinado, A. C., Hammond, J., & Scott, A. O. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.07.036 · Cited by 85
Determination of paracetamol in intact tablets by use of near infrared transmittance spectroscopy
Eustaquio, A., Blanco, M., Jee, R. D., & Moffat, A. C. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00815-0 · Cited by 83
Chablani, L., Taylor, M. K., Mehrotra, A., Rameas, P., & Stagner, W. C. (2011) · AAPS PharmSciTech · doi:10.1208/s12249-011-9669-z · Cited by 80
Real time release testing of tablet content and content uniformity
Goodwin, D., van den Ban, S., Denham, M., & Barylski, I. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.011 · Cited by 79 · cited 19×
“There are various approaches, such as in-process testing, RTRT, and finished product testing [11,14,15].”
MethodInfluentialPeng, Y., & Gardner, D. J. (2012) · Wood and Fiber Science (Society of Wood Science and Technology) · Cited by 78
Rantanen, J., Räsänen, E., Antikainen, O. K., Mannermaa, J., & Yliruusi, J. K. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00108-3 · Cited by 74
Davies, T. (1998) · Analusis · doi:10.1051/analusis:199826040017 · Cited by 74
In-Situ Near-Infrared Spectroscopy Monitoring of the Lyophilization Process
Brűlls, M., Folestad, S., Sparén, A., & Rasmuson, A. (2003) · Pharmaceutical Research · doi:10.1023/a:1022680810474 · Cited by 69 · cited 3×
“Multivariate data analysis was performed using PCA and/or multivariate curve resolution and by comparing the reference spectra of mannitol forms [6].”
BackgroundMethodGendre, C., Genty, M., Boiret, M., Julien, M., Meunier, L., Lecoq, O., Baron, M., Chaminade, P., & Péan, J. M. (2011) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2011.04.017 · Cited by 68
Feasibility of Raman spectroscopy as PAT tool in active coating
Müller, J., Knop, K., Thies, J., Uerpmann, C., & Kleinebudde, P. (2010) · Drug Development and Industrial Pharmacy · doi:10.3109/03639040903225109 · Cited by 66
Monitoring Blending of Pharmaceutical Powders with Multipoint NIR Spectroscopy
Scheibelhofer, O., Balak, N., Wahl, P. R., Koller, D. M., Glasser, B. J., & Khinast, J. (2012) · AAPS PharmSciTech · doi:10.1208/s12249-012-9910-4 · Cited by 65
Ellison, C. D., Ennis, B. J., Hamad, M. L., & Lyon, R. C. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.04.020 · Cited by 63
Quality by Design, Part I: Application of NIR Spectroscopy to Monitor Tablet Manufacturing Process
Tabasi, S. H., Fahmy, R. M., Bensley, D., O'Brien, C., & Hoag, S. W. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21303 · Cited by 63
Development of an Ointment Formulation Using Hot-Melt Extrusion Technology
Bhagurkar, A. M., Angamuthu, M., Patil, H., Tiwari, R. V., Maurya, A., Hashemnejad, S. M., Kundu, S., Murthy, S. N., & Repka, M. A. (2015) · AAPS PharmSciTech · doi:10.1208/s12249-015-0453-3 · Cited by 61
Khorasani, M. R., Amigo, J. M., Sun, C. C., Bertelsen, P., & Rantanen, J. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.04.008 · Cited by 60
Tabasi, S. H., Fahmy, R. M., Bensley, D., O'Brien, C., & Hoag, S. W. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21307 · Cited by 60
Zeng, S., Wang, L., Chen, T., Wang, Y., Mo, H., & Qu, H. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.04.025 · Cited by 60
Henn, R., Anita, S., & Huck, C. W. (2016) · Food Control · doi:10.1016/j.foodcont.2016.03.037 · Cited by 60
Luukkonen, P., Fransson, M., Björn, I. N., Hautala, J., Lagerholm, B., & Folestad, S. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20998 · Cited by 59
RTD modeling of a continuous dry granulation process for process control and materials diversion
Kruisz, J., Rehrl, J., Sacher, S., Aigner, I., Horn, M., & Khinast, J. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.06.001 · Cited by 59
Continuous manufacturing process monitoring of pharmaceutical solid dosage form: A case study
Roggo, Y., Pauli, V., Jelsch, M., et al. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112971 · Cited by 57
Bogomolov, A. Y., Engler, M., Melichar, M., & Wigmore, A. J. (2010) · Journal of Chemometrics · doi:10.1002/cem.1329 · Cited by 57
Khorasani, M. R., Amigo, J. M., Sonnergaard, J. M., Olsen, P. M., Bertelsen, P., & Rantanen, J. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.02.008 · Cited by 55
Digital imaging as a process analytical technology tool for fluid-bed pellet coating process
Možina, M., Tomaževič, D., Leben, S., Pernuš, F., & Likar, B. (2010) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2010.06.001 · Cited by 54
Importance of evaluating the consolidation of granules manufactured by high shear mixer
Ohno, I., Hasegawa, S., Yada, S., Kusai, A., Moribe, K., & Yamamoto, K. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.01.030 · Cited by 53
Chen, W., Chang, S., Kiang, S., Marchut, A. J., Lyngberg, O. K., Wang, J., Rao, V. M., Desai, D. S., Stamato, H. J., & Early, W. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22044 · Cited by 52 · cited 1×
“Thousands of code lengths are measured simultaneously, and based on this, a code-length distribution can be generated to measure particle properties such as particle size and size distribution in real-time [92,93,95].”
BackgroundMeng, W., Román-Ospino, A. D., Panikar, S. S., O'Callaghan, C., Gilliam, S. J., Ramachnadran, R., & Muzzio, F. J. (2019) · Advanced Powder Technology · doi:10.1016/j.apt.2019.01.017 · Cited by 50
A Review of the Applications of OCT for Analysing Pharmaceutical Film Coatings
Lin, H., Zhang, Z., Markl, D., Zeitler, J. A., & Shen, Y. (2018) · Applied Sciences · doi:10.3390/app8122700 · Cited by 50
Effect of force feeder on tablet strength during compression
Narang, A. S., Rao, V. M., Guo, H., Lu, J. H., & Desai, D. S. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.08.027 · Cited by 48
Burggraeve, A., Silva, A. F., den Kerkhof, T. V., Hellings, M., Vervaet, C., Remon, J. P., Heyden, Y. V., & Beer, T. D. (2012) · Talanta · doi:10.1016/j.talanta.2012.07.054 · Cited by 48
Durão, P., Fauteux‐Lefebvre, C., Guay, J.-M., Abatzoglou, N., & Gosselin, R. (2016) · Talanta · doi:10.1016/j.talanta.2016.11.013 · Cited by 46
El‐Hagrasy, A. S., Chang, S., Desai, D. S., & Kiang, S. (2006) · Journal of Pharmaceutical Innovation · doi:10.1007/bf02784879 · Cited by 46
Rapid Spectroscopic Analysis of Marzipan—Comparative Instrumentation
Christensen, J., Nørgaard, L., Heimdal, H., Pedersen, J. G., & Engelsen, S. B. (2004) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.408 · Cited by 45
Towards a robust water content determination of freeze-dried samples by near-infrared spectroscopy
Grohganz, H., Gildemyn, D., Skibsted, E., Flink, J. M., & Rantanen, J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.07.035 · Cited by 42
Barimani, S., & Kleinebudde, P. (2017) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2017.05.011 · Cited by 41
Harting, J., & Kleinebudde, P. (2018) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2018.01.015 · Cited by 40
Peters, J., Teske, A., Taute, W., Döscher, C., Höft, M., Knochel, R. H., & Breitkreutz, J. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.040 · Cited by 40
Ávila, C., Ferré, J., de Oliveira, R. R., de Juan, A., Sinclair, W. E., Mahdi, F. M., Hassanpour, A., Hunter, T. N., Bourne, R. A., & Muller, F. L. (2020) · Pharmaceutical Research · doi:10.1007/s11095-020-02787-y · Cited by 39
Li, W., Worosila, G. D., Wang, W., & Mascaro, T. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20501 · Cited by 38
Lee, M., Park, C.-R., Kim, A.-Y., Kwon, B.-S., Bang, K.-H., Cho, Y.-S., Jeong, M.-Y., & Choi, G.-J. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21795 · Cited by 38
Rosas, J. G., de Waard, H., Beer, T. D., Vervaet, C., Remon, J. P., Hinrichs, W. L. J., Frijlink, H. W., & Blanco, M. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.010 · Cited by 38
Bosca, S., Barresi, A., & Fissore, D. (2013) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2013.04.008 · Cited by 38
Brouckaert, D., Meyer, L. D., Vanbillemont, B., Bockstal, P.-J. V., Lammens, J., Mortier, S. T. F. C., Corver, J. A. W. M., Vervaet, C., Nopens, I., & Beer, T. D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03647 · Cited by 37
Wirges, M., Funke, A. P., Serno, P., Knop, K., & Kleinebudde, P. (2013) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.01.037 · Cited by 37
Chavez, P.-F., Sacré, P., Bleye, C. D., Netchacovitch, L., Mantanus, J., Motte, H., Schubert, M., Hubert, P., & Ziémons, E. (2015) · Talanta · doi:10.1016/j.talanta.2015.08.018 · Cited by 36
Gavan, A. D., Iurian, S., Casian, T., Porfire, A. S., Porav, A. S., Voina, I., Oprea, A., & Tomuță, I. (2019) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2019.03.003 · Cited by 35
Muhaimin, M., & Bodmeier, R. A. (2017) · Polymer International · doi:10.1002/pi.5436 · Cited by 35
Pauli, V., Elbaz, F., Kleinebudde, P., & Krumme, M. (2018) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-018-9320-6 · Cited by 34
NIR analysis of pharmaceutical samples without reference data: Improving the calibration
Blanco, M., Cueva-Mestanza, R., & Peguero, A. (2011) · Talanta · doi:10.1016/j.talanta.2011.07.082 · Cited by 34
Spray granulation for drug formulation
Loh, Z. H., Er, D. Z. L., Chan, L. W., et al. (2011) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2011.610304 · Cited by 33
Monitoring quality attributes for high-shear wet granulation with audible acoustic emissions
Hansuld, E. M., Briens, L. A., Sayani, A. P., & McCann, J. A. B. (2011) · Powder Technology · doi:10.1016/j.powtec.2011.09.034 · Cited by 31
Harting, J., & Kleinebudde, P. (2019) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2019.02.015 · Cited by 31 · cited 3×
“- Moisture content - Granule size Raman RXN2 hybrid analyzer (Kaiser Optical Systems, Ann Arbor, MI, USA) - Dissolution - Content uniformity - Moisture content [9]”
MethodClavaud, M., Lema-Martinez, C., Roggo, Y., Bigalke, M., Guillemain, A., Hubert, P., Ziémons, E., & Allmendinger, A. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2019.08.028 · Cited by 29
Reddy, J. P., Jones, J. W., Wray, P. S., Dennis, A. B., Brown, J. L., & Timmins, P. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.021 · Cited by 28 · cited 5×
“It can analyze the IQAs and CQAs of drug content [160–162] during the blending process, moisture content [8,9] during the drying and granulation process, and coating thickness and content [157,163,164] during the coating process, as well as enable polymorph identification in API preparation [165–167], granuleformulati…”
BackgroundMethodInfluentialHyperspectral imaging and its applications
Serranti, S., & Bonifazi, G. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2234976 · Cited by 27
Kim, B., & Woo, Y. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.03.001 · Cited by 26
Gupta, A., Austin, J., Davis, S. A., Harris, M. T., & Reklaitis, G. V. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24409 · Cited by 25
Möltgen, C.-V., Herdling, T., & Reich, G. (2013) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2013.09.011 · Cited by 24
Panzitta, M., Calamassi, N., Sabatini, C., Grassi, M., Spagnoli, C., Vizzini, V., Ricchiuto, E., Venturini, A., Brogi, A., Font, J. B., et al. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120551 · Cited by 23 · cited 19×
“There are various approaches, such as in-process testing, RTRT, and finished product testing [11,14,15].”
MethodInfluentialStudy progression in application of process analytical technologies on film coating
Peng, T., Huang, Y., Mei, L., Wu, L., Chen, L., Pan, X., & Wu, C. (2014) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2014.10.002 · Cited by 20
Quantitative analysis of topical gels and ointments by FT-Raman spectroscopy
Mazurek, S., & Szostak, R. (2015) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2015.12.005 · Cited by 20
Real-time monitoring of multi-layered film coating processes using Raman spectroscopy
Radtke, J., & Kleinebudde, P. (2020) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.05.018 · Cited by 20
Key information related to quality by design (QbD) applications in analytical methods development
Araújo, A., Andrade, D. F., Babos, D. V., Castro, J. P., Garcia, J. A., Sperança, M. A., Gamela, R. R., Machado, R. C., Costa, V. C., Guedes, W. N., et al. (2020) · Brazilian Journal of Analytical Chemistry · doi:10.30744/brjac.2179-3425.rv-27-2020 · Cited by 19 · cited 1×
“The QbD approach has been introduced to overcome this and to improve understanding of product performance, identify critical process parameters (CPPs) during quality risk assessment of the product manufacturing process, and establish appropriate control strategies for each variable [13,22].”
MethodMiniaturized NIR spectroscopy for the determination of main carbohydrates in syrup
Henn, R., Kirchler, C. G., & Huck, C. W. (2017) · NIR news · doi:10.1177/0960336017695732 · Cited by 18
PAT-based batch statistical process control of a manufacturing process for a pharmaceutical ointment
Bostijn, N., Dhondt, W., Vervaet, C., & Beer, T. D. (2019) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2019.05.024 · Cited by 17
Role of dwell on compact deformation during tableting: an overview
Anbalagan, P., Liew, C. V., & Heng, P. W. S. (2017) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-017-0306-z · Cited by 16
Kothari, B. H., Fahmy, R. M., Claycamp, H. G., Moore, C. M. V., Chatterjee, S., & Hoag, S. W. (2016) · AAPS PharmSciTech · doi:10.1208/s12249-016-0569-0 · Cited by 15
Barimani, S., Šibanc, R., & Kleinebudde, P. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.038 · Cited by 15
Kim, J. Y., Chun, M. H., & Choi, D. H. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13010080 · Cited by 14 · cited 21×
“QbD is defined in ICH Q8 guidelines as “a systematic approach to development that begins with predefined objectives and emphasizes product and process understanding and process control, based on sound science and quality risk management.””
MethodInfluentialSelf-citationBadawy, S. I. F., Narang, A. S., LaMarche, K. R., Subramanian, G. A., & Varia, S. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-810460-6.00026-9 · Cited by 9
Real Time Release Testing - A New Quality Paradigm for Pharmaceutical Development
Dasu, M., & Naresh, J. R. (2013) · Cited by 6
Real Time Release Testing-A Review
Devi, N. R. G., & Chandramouli, R. (2018) · doi:10.18579/jpcrkc/2017/16/4/111489 · Cited by 6 · cited 1×
“There are various approaches, such as in-process testing, RTRT, and finished product testing [11,14,15].”
MethodBenjasirimongkol, P., Piriyaprasarth, S., & Sriamornsak, P. (2019) · Key engineering materials · doi:10.4028/www.scientific.net/kem.819.246 · Cited by 5
Jiménez, Á. R., Figueroa, C. V., & Morantes, M. T. A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
Cited by
Multi‐Dimensional Technology—Recent Advances and Applications for Biotherapeutic Characterization
Bouvarel, T., Camperi, J., & Guillarme, D. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300928 · Cited by 20
Kumar, R., Sarin, D., & Rathore, A. S. (2023) · ELECTROPHORESIS · doi:10.1002/elps.202200208 · Cited by 10
Metadata
- Authors
- Kim, E. J., Kim, J. H., Kim, M.-S., Jeong, S. H., & Choi, D. H.
- Venue
- Pharmaceutics
- Publisher
- MDPI AG
- Published
- 2021-06-21
- Volume
- 13
- Issue
- 6
- Pages
- 919
- ISSN
- 1999-4923 (ISSN-L)
- OpenAlex
- W3174799230
- Cited by
- 191
- References
- 130
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.