Combining Mechanistic Modeling and Raman Spectroscopy for Monitoring Antibody Chromatographic Purification
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Chromatography is widely used in biotherapeutics manufacturing, and the corresponding underlying mechanisms are well understood. To enable process control and automation, spectroscopic techniques are very convenient as on-line sensors, but their application is often limited by their sensitivity. In this work, we investigate the implementation of Raman spectroscopy to monitor monoclonal antibody (mAb) breakthrough (BT) curves in chromatographic operations with a low titer harvest. A state estimation procedure is developed by combining information coming from a lumped kinetic model (LKM) and a Raman analyzer in the frame of an extended Kalman filter approach (EKF). A comparison with suitable experimental data shows that this approach allows for the obtainment of reliable estimates of antibody concentrations with reduced noise and increased robustness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EKF was applied to the Raman-PLS and LKM models to weight the relative input of the data model compared to the mechanistic model. The filter resulted in a more accurate mAb quantification, especially at the incipient breakthrough region.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
The cited source says what the claim attributes to it.
In the citing paper
“While Raman-PLS model had resulted in a reasonable model performance for the data rotations (RMSECV range 0.04–0.042, R2 range 0.7–0.86), and captured the trend of the breakthrough curve. However, there was also prediction scatter around the reference values.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
The cited source says what the claim attributes to it.
In the citing paper
“Lumped kinetic model was shown to have a good ability to predict the shape of the breakthrough run curve.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084 · cited 1×
“The nonlinear iterative partial least squares (NIPALS) algorithm [27] was used to calibrate predictive PLS models, which regressed spectral data on HPLC reference values, including a threefold cross validation (CV) [28].”
MethodStandard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance Spectra
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202201 · Cited by 3,867 · cited 1×
“The modeling procedure included Savitzky–Golay smoothing with a second polynomial order and a frame size of 51 Raman shift wavenumbers [24], spectrum wise standard normal variate (SNV) processing [25], and Raman shift wavenumber wise mean centering on spectra and reference values [26].”
Methodvan den Berg, R. A., Hoefsloot, H. C., Westerhuis, J. A., Smilde, A. K., & van der Werf, M. J. (2006) · BMC Genomics · doi:10.1186/1471-2164-7-142 · Cited by 2,450
Industrial Applications of the Kalman Filter: A Review
Auger, F., Hilairet, M., Guerrero, J. M., Monmasson, E., Orlowska-Kowalska, T., & Katsura, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2236994 · Cited by 590
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
Assessment of Recent Process Analytical Technology (PAT) Trends: A Multiauthor Review
Simon, L. L., Pataki, H., Marosi, G., Meemken, F., Hungerbühler, K., Baiker, A., Tummala, S., Glennon, B., Kuentz, M., Steele, G., et al. (2015) · Organic Process Research & Development · doi:10.1021/op500261y · Cited by 439
Understanding the Basis of the Kalman Filter Via a Simple and Intuitive Derivation [Lecture Notes]
Faragher, R. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203621 · Cited by 424 · cited 1×
“While a general introduction to Kalman filtering is given in [20], a more detailed description is provided in [21].”
Method
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“[82] A comparison of the developed flow cells is shown in Fig.”
BackgroundKhuat, T. T., Bassett, R., Otte, E. A., Grevis-James, A., & Gabryś, B. (2024) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2024.108585 · Cited by 108
Narayanan, H., Behle, L., Luna, M. F., Sokolov, M., Guillén‐Gosálbez, G., Morbidelli, M., & Butté, A. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27437 · Cited by 91
“Thus, an error to represent spectroscopic soft sensor accuracy is chosen (Feidl et al., 2019; Ohadi et al., 2015).”
Self-citationHybrid Models for the simulation and prediction of chromatographic processes for protein capture
Narayanan, H., Seidler, T., Luna, M. F., Sokolov, M., Morbidelli, M., & Butté, A. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462248 · Cited by 73
“The implementation and performance of the hybrid modeling framework are also demonstrated for a set of experimental data reported by Feidl et al. [15].”
InfluentialSelf-citationIntegration and digitalization in the manufacturing of therapeutic proteins
Narayanan, H., Sponchioni, M., & Morbidelli, M. (2021) · Chemical Engineering Science · doi:10.1016/j.ces.2021.117159 · Cited by 67
Self-citationNarayanan, H., Luna, M. F., Sokolov, M., Arosio, P., Butté, A., & Morbidelli, M. (2021) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.1c01317 · Cited by 60
Self-citationGoldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., et al. (2020) · Processes · doi:10.3390/pr8091179 · Cited by 48
“through the development of a Raman flow cell [41,42].”
BackgroundAnalyzing and understanding the robustness of bioprocesses
Becker, L., Sturm, J., Eiden, F., & Holtmann, D. (2023) · Trends in biotechnology · doi:10.1016/j.tibtech.2023.03.002 · Cited by 50
Rathore, A. S., Nikita, S., Thakur, G., & Deore, N. (2021) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2021.100671 · Cited by 44
Recent Advances and Future Directions in Downstream Processing of Therapeutic Antibodies
Matte, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23158663 · Cited by 36
Model-assisted approaches for continuous chromatography: Current situation and challenges
Lin, D., Zhang, Q., & Yao, S. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461855 · Cited by 43
Armstrong, A., Horry, K., Cui, T., Hulley, M., Turner, R., Farid, S. S., Goldrick, S., & Bracewell, D. G. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461914 · Cited by 40
Wang, J., Chen, J., Studts, J., & Wang, G. (2023) · mAbs · doi:10.1080/19420862.2023.2220149 · Cited by 37
Rolinger, L., Rüdt, M., & Hubbuch, J. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27894 · Cited by 33
Usage of Digital Twins Along a Typical Process Development Cycle
Sinner, P., Daume, S., Herwig, C., & Kager, J. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_149 · Cited by 33
Raman spectroscopy provides valuable process insights for cell-derived and cellular products
Matuszczyk, J., Zijlstra, G., Ede, D., Ghaffari, N., Yuh, J., & Brivio, V. (2023) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2023.102937 · Cited by 28
Nitika, N., Keerthiveena, B., Thakur, G., & Rathore, A. S. (2024) · Pharmaceutical Research · doi:10.1007/s11095-024-03663-9 · Cited by 26
“Applications in the downstream process, however, have been limited for detection of breakthrough in Protein A chromatography [40, 41] and determination of concentration and purity of monomer with respect to aggregate of an Fc fusion protein [42].”
Model based strategies towards protein A resin lifetime optimization and supervision
Feidl, F., Luna, M. F., Podobnik, M., Vogg, S., Angelo, J., Potter, K. D., Wiggin, E., Xu, X., Ghose, S., Li, Z. J., et al. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461261 · Cited by 26
Self-citationPeng, J., Khuat, T. T., Musiał, K., & Gabryś, B. (2025) · Biotechnology Advances · doi:10.1016/j.biotechadv.2025.108749 · Cited by 33
Wang, T., Cauchon, N. S., Kirwan, J. P., Joubert, M. K., Algorri, M., Bell, B., Soto, R. J., & Semin, D. J. (2024) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2024.12.025 · Cited by 30
González-Hernández, Y., & Perré, P. (2024) · Metabolic Engineering Communications · doi:10.1016/j.mec.2024.e00232 · Cited by 23
“Mechanistic modeling and Raman spectroscopy have been combined for monitoring antibody chromatographic purification by Feidl et al. (2019).”
MethodSchiemer, R., Rüdt, M., & Hubbuch, J. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1228846 · Cited by 23
Dietrich, A., Schiemer, R., Kurmann, J., Zhang, S., & Hubbuch, J. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1399938 · Cited by 21
“…raw material testing (Li et al., 2010), cell culture (Abu-Absi et al., 2011; Berry et al., 2015; Golabgir and Herwig, 2016), chromatography (Feidl et al., 2019; Rolinger et al., 2021; Wang et al., 2023), fi ltration (Rolinger et al., 2023), freezing (Roessl et al., 2014; Weber and Hubbuch,…”
MethodTan, H. Y., Yang, J., Linnes, J. C., Welch, C. J., & Bruening, M. L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03654 · Cited by 16
The Kalman Filter for the Supervision of Cultivation Processes
Yousefi-Darani, A., Paquet-Durand, O., & Hitzmann, B. (2020) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2020_145 · Cited by 15
An adaptive soft‐sensor for advanced real‐time monitoring of an antibody‐drug conjugation reaction
Schiemer, R., Weggen, J. T., Schmitt, K. M., & Hubbuch, J. J. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28428 · Cited by 17
Alcântara, J. M. G., Iannacci, F., Morbidelli, M., & Sponchioni, M. (2023) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2023.10.005 · Cited by 16
Self-citationPauk, J. N., Igwe, C. L., Herwig, C., & Kager, J. (2024) · Chemical Engineering Science · doi:10.1016/j.ces.2024.119774 · Cited by 11
Khanal, O. (2022) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2022.102796 · Cited by 8
Wang, J., Chen, J., Juergen, H., Studts, J., & Wang, G. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28514 · Cited by 8
“At present, it is possible to measure protein concentration using an in ‐ line Raman sensor (Feidl et al., 2019a, 2019b; Rolinger et al., 2021; Yilmaz et al., 2020).”
InfluentialRolinger, L., Rüdt, M., & Hubbuch, J. J. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27616 · Cited by 7
Carvalho, M. F., da Cruz, A. L. B., Haringa, C., Ottens, M., & Klijn, M. E. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70139 · Cited by 6
Heyer‐Müller, J., Schiemer, R., Lopinski, M., Wang, C., Willems, F., Robbel, L., Schmitt, M., & Hubbuch, J. J. (2025) · Engineering in Life Sciences · doi:10.1002/elsc.70044 · Cited by 6
Real-time monitoring of gradient chromatography using dual Kalman-filters
Andersson, G. Z., Espinoza, D., Andersson, N., & Nilsson, B. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.465161 · Cited by 3
Heyer‐Müller, J., Schiemer, R., Robbel, L., Schmitt, M., & Hubbuch, J. J. (2026) · Biotechnology and Bioengineering · doi:10.1002/bit.70163 · Cited by 4
“Raman spectroscopy has previously been used in bioseparations, but has been shown to have limited accuracy due to the inherent variation in spectral signals (Feidl et al. 2019; Rolinger et al. 2020b, 2023).”
Mandenius, C. (2021) · Engineering in Life Sciences · doi:10.1002/elsc.202100116 · Cited by 3
“Thus, all spectroscopic and microscopic methods are favored due to their responsiveness with the speed of light (near-infrared spectroscopy [14–16], multi-way fluorescence spectroscopies [17–19] and Raman spectroscopy [20–22]).”
BackgroundVaskó, D., Hajdú, D. K., Márkus, E., Pantea, E., Ujj, D., Fehér, C., Nagy, Z. K., & Hirsch, E. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.126129 · Cited by 2
A Digital Twin Framework for Bioprocess Development Using IoT Sensor Data
Bozorgi, Z. D., Polyvyanyy, A., Rosa, M. L., Otte, E. A., & Armas-Cervantes, A. (2026) · Internet of things · doi:10.1007/978-3-031-90746-3_12 · Cited by 2
Machleid, R., Goertz, M., Grimm, C., Trygg, J., Mathias, S., & Surowiec, I. (2026) · Biotechnology Journal · doi:10.1002/biot.70208 · Cited by 2
Paiva, C. S., Radi, H. E., Chagas, D., Grollier, K., Cailletaud, J., Delacroix, S., Gabaldi, P., Faria, T. Q., & Peixoto, C. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18081016 · Cited by 2
“Feidl et al. (2019) [40] successfully used Raman spectroscopy to monitor the breakthrough of mAbs in a Protein A column by implementing a multi-pass flow cell between the elution stream and the sample fractionator of the chromatography system.”
Narayanan, H., von Stosch, M., Luna, M. F., Bournazou, M. N. C., Butté, A., & Sokolov, M. (2021) · Wiley eBooks · doi:10.1002/9783527827343.ch8 · Cited by 3
Self-citationNanda, S. S., Park, D.-G., & Yi, D. K. (2025) · Biosensors · doi:10.3390/bios15050265 · Cited by 3
“Feidl et al. [79] integrated mechanistic modeling with Raman spectroscopy in down-stream processing (DSP) to track mAb breakthrough curves during low-titer harvest chromatography technique shows how to quickly and automatically train and validate top-notch Raman models for speci fi c processes in…”
Special Issue: Bioprocess Monitoring and Control
Hitzmann, B. (2020) · Processes · doi:10.3390/pr8070854 · Cited by 1
“[7] investigated the monitoring of monoclonal antibody breakthrough curves in chromatographic downstream operations.”
Background2027 A local buckling models for box columns with constant strain triangular elements
桑原, 進., & 澤井, 祥. (1994) · 日本建築学会近畿支部研究報告集. 構造系
Nutzung von digitalen Zwillingen entlang eines typischen Prozessentwicklungszyk lus
Sinner, P., Daume, S., Herwig, C., & Kager, J. (2025) · Springer eBooks · doi:10.1007/978-3-031-75698-6_4
An Introduction to Bioprocessing and Industrial Bio-Manufacturing Foundation and Evolution
Debnath, R., Siddiqui, M. A., Bordoloi, T., Hussain, I., Parbin, S., Alam, M., Kumar, S., Srivastava, S., & Sahu, R. (2025) · IGI Global eBooks · doi:10.4018/979-8-3373-2873-7.ch001
Metadata
- Authors
- Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A.
- Affiliations
- ETH Zurich (CH)
- Merck Serono S.A. (Switzerland) (CH)
- Corresponding author
- Butté, Alessandro
- Venue
- Processes
- Publisher
- MDPI AG
- Published
- 2019-10-01
- Volume
- 7
- Issue
- 10
- Pages
- 683
- ISSN
- 2227-9717 (ISSN-L)
- OpenAlex
- W2978951492
- Cited by
- 46
- References
- 40
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 8 · 2023: 7 · 2022: 3 · 2021: 9 · 2020: 8
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Processes (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Conicet (submittedVersion, cc-by)
- Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
- ETH Zürich Research Collection (cc-by)
- Funders
- KTI Program of the Swiss Economic Ministry (19190.2 PFIW-IW)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- monoclonal antibody purification, Raman spectroscopy, extended Kalman filter, lumped kinetic model, state estimation, real-time process monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.