Combining Mechanistic Modeling and Raman Spectroscopy for Monitoring Antibody Chromatographic Purification
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Chromatography is widely used in biotherapeutics manufacturing, and the corresponding underlying mechanisms are well understood. To enable process control and automation, spectroscopic techniques are very convenient as on-line sensors, but their application is often limited by their sensitivity. In this work, we investigate the implementation of Raman spectroscopy to monitor monoclonal antibody (mAb) breakthrough (BT) curves in chromatographic operations with a low titer harvest. A state estimation procedure is developed by combining information coming from a lumped kinetic model (LKM) and a Raman analyzer in the frame of an extended Kalman filter approach (EKF). A comparison with suitable experimental data shows that this approach allows for the obtainment of reliable estimates of antibody concentrations with reduced noise and increased robustness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EKF was applied to the Raman-PLS and LKM models to weight the relative input of the data model compared to the mechanistic model. The filter resulted in a more accurate mAb quantification, especially at the incipient breakthrough region.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
The cited source says what the claim attributes to it.
In the citing paper
“While Raman-PLS model had resulted in a reasonable model performance for the data rotations (RMSECV range 0.04–0.042, R2 range 0.7–0.86), and captured the trend of the breakthrough curve. However, there was also prediction scatter around the reference values.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
The cited source says what the claim attributes to it.
In the citing paper
“Lumped kinetic model was shown to have a good ability to predict the shape of the breakthrough run curve.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [82]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084 · cited 1×
“The nonlinear iterative partial least squares (NIPALS) algorithm [27] was used to calibrate predictive PLS models, which regressed spectral data on HPLC reference values, including a threefold cross validation (CV) [28].”
MethodStandard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance Spectra
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202201 · Cited by 3,867 · cited 1×
“The modeling procedure included Savitzky–Golay smoothing with a second polynomial order and a frame size of 51 Raman shift wavenumbers [24], spectrum wise standard normal variate (SNV) processing [25], and Raman shift wavenumber wise mean centering on spectra and reference values [26].”
Methodvan den Berg, R. A., Hoefsloot, H. C., Westerhuis, J. A., Smilde, A. K., & van der Werf, M. J. (2006) · BMC Genomics · doi:10.1186/1471-2164-7-142 · Cited by 2,450
Industrial Applications of the Kalman Filter: A Review
Auger, F., Hilairet, M., Guerrero, J. M., Monmasson, E., Orlowska-Kowalska, T., & Katsura, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2236994 · Cited by 590
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
Assessment of Recent Process Analytical Technology (PAT) Trends: A Multiauthor Review
Simon, L. L., Pataki, H., Marosi, G., Meemken, F., Hungerbühler, K., Baiker, A., Tummala, S., Glennon, B., Kuentz, M., Steele, G., et al. (2015) · Organic Process Research & Development · doi:10.1021/op500261y · Cited by 439
Understanding the Basis of the Kalman Filter Via a Simple and Intuitive Derivation [Lecture Notes]
Faragher, R. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203621 · Cited by 424 · cited 1×
“While a general introduction to Kalman filtering is given in [20], a more detailed description is provided in [21].”
MethodPreparative liquid chromatography
Guiochon, G. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01471-6 · Cited by 417
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332
Protein Chromatography: Process Development and Scale‐Up
Carta, G., & Jungbauer, A. (2010) · Wiley eBooks · doi:10.1002/9783527630158 · Cited by 276
Raman spectroscopy of protein pharmaceuticals
Wen, Z. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20895 · Cited by 262 · cited 1×
“This is in line with the fact that proteins exhibit several Raman bands in the region between 2500–4000 cm−1 [37].”
BackgroundAn optimal state estimation model of sensory integration in human postural balance
Kuo, A. D. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/3/s07 · Cited by 256
Comparison of protein A affinity sorbents
Hahn, R., Schlegel, R., & Jungbauer, A. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00092-8 · Cited by 246 · cited 1×
“36 [30]), x is the coordinate along the column longitudinal axis, LCol is the column length (LCol= 5 cm), DL is the apparent axial dispersion coefficient, φ = (1− ε)/ε is the phase ratio of the column, q is the solid phase concentration of the protein, km is the mass transfer coefficient, and q∗ is the equilibrium sol…”
BackgroundRead, E. K., Park, J. T., Shah, R. B., Riley, B. S., Brorson, K. A., & Rathore, A. S. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22528 · Cited by 217
Process analytical technology (PAT) for biopharmaceuticals
Glassey, J., Gernaey, K. V., Clemens, C., Schulz, T. W., Oliveira, R., Striedner, G., & Mandenius, C. (2011) · Biotechnology Journal · doi:10.1002/biot.201000356 · Cited by 211
Craven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
Quality by control: Towards model predictive control of mammalian cell culture bioprocesses
Sommeregger, W., Sissolak, B., Kandra, K., von Stosch, M., Mayer, M., & Striedner, G. (2017) · Biotechnology Journal · doi:10.1002/biot.201600546 · Cited by 159
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Guiochon, G. A., Shirazi, D. G., Felinger, A., & Katti, A. M. (2006) · Elsevier eBooks · doi:10.1016/b978-012370537-2/50030-8 · Cited by 128
Systematic estimation of state noise statistics for extended Kalman filters
Valappil, J., & Georgakis, C. (2000) · AIChE Journal · doi:10.1002/aic.690460209 · Cited by 127 · cited 2×
“The time-varying process noise covariance Q was computed on-line at any given time tk using a Monte Carlo approach, as reported in [33].”
MethodHow To NOT Make the Extended Kalman Filter Fail
Schneider, R., & Georgakis, C. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie300415d · Cited by 125 · cited 3×
“Given such a system, the EKF can estimate states from noisy measurements through a recursive procedure, including two main steps [34,35].”
MethodModel based adaptive control of a continuous capture process for monoclonal antibodies production
Steinebach, F., Angarita, M., Karst, D. J., Müller‐Späth, T., & Morbidelli, M. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.03.014 · Cited by 108 · cited 1×
“Nevertheless, the EKF performance reported in this work is already sufficient for the implementation in the frame of the control of a capture chromatographic step, where the range of interest is around 70% of the breakthrough value [39].”
BackgroundSelf-citationBaur, D., Angarita, M., Müller‐Späth, T., & Morbidelli, M. (2016) · Biotechnology Journal · doi:10.1002/biot.201500223 · Cited by 107 · cited 1×
“The chromatographic process was modelled using the lumped kinetic model (LKM) [14,29]:”
MethodSelf-citationFeidl, F., Vogg, S., Wolf, M., Podobnik, M., Ruggeri, C., Ulmer, N., Wälchli, R., Souquet, J., Broly, H., Butté, A., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27296 · Cited by 99
Self-citationA multiscale view of therapeutic protein aggregation: A colloid science perspective
Nicoud, L., Owczarz, M., Arosio, P., & Morbidelli, M. (2015) · Biotechnology Journal · doi:10.1002/biot.201400858 · Cited by 86 · cited 1×
“In the future, this approach might be extended to other applications where deterministic knowledge is available, like in the monitoring of protein aggregation [40], crystallization [41] or in-line buffer preparation.”
BackgroundSelf-citationRüdt, M., Briskot, T., & Hubbuch, J. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.11.010 · Cited by 83 · cited 1×
“Available spectroscopic techniques range from UV/vis and Fourier transform infrared spectroscopy to dynamic light scattering [6].”
Santos, R. M., Kessler, J., Salou, P., Menezes, J. C., & Peinado, A. (2018) · Biotechnology Progress · doi:10.1002/btpr.2635 · Cited by 82
Predictive models for protein crystallization
Rupp, B. (2004) · Methods · doi:10.1016/j.ymeth.2004.03.031 · Cited by 76 · cited 1×
“In the future, this approach might be extended to other applications where deterministic knowledge is available, like in the monitoring of protein aggregation [40], crystallization [41] or in-line buffer preparation.”
BackgroundNg, C. K. S., Osuna-Sanchez, H., Valéry, E., Sørensen, E., & Bracewell, D. G. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.05.010 · Cited by 73 · cited 1×
“An empirical correlation was used for the mass transfer coefficient km, approximating hindered mass transfer due to pore blockage and other effects [32]:”
MethodFeidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59 · cited 4×
“Recently, a successful implementation of Raman spectroscopy for the on-line monitoring of monoclonal antibody (mAb) concentrations in downstream processing was reported by Feidl et al [10].”
BackgroundMethodSelf-citationWolf, M. K. F., Müller, A., Souquet, J., Broly, H., & Morbidelli, M. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26999 · Cited by 39
Self-citationArndt, M., & Hitzmann, B. (2008) · Biotechnology Progress · doi:10.1021/bp034156p · Cited by 31
Krämer, D., & King, R. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.07.235 · Cited by 31
Comparison of Particle Filter and Extended Kalman Filter Algorithms for Monitoring of Bioprocesses
Stelzer, I. V., Kager, J., & Herwig, C. (2017) · Computer-aided chemical engineering/Computer aided chemical engineering · doi:10.1016/b978-0-444-63965-3.50249-x · Cited by 28
Simon, D. (2006) · Wiley eBooks · doi:10.1002/0470045345.ch11 · Cited by 12 · cited 1×
“While a general introduction to Kalman filtering is given in [20], a more detailed description is provided in [21].”
Method
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“[82] A comparison of the developed flow cells is shown in Fig.”
BackgroundKhuat, T. T., Bassett, R., Otte, E. A., Grevis-James, A., & Gabryś, B. (2024) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2024.108585 · Cited by 108
Narayanan, H., Behle, L., Luna, M. F., Sokolov, M., Guillén‐Gosálbez, G., Morbidelli, M., & Butté, A. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27437 · Cited by 91
“Thus, an error to represent spectroscopic soft sensor accuracy is chosen (Feidl et al., 2019; Ohadi et al., 2015).”
Self-citationHybrid Models for the simulation and prediction of chromatographic processes for protein capture
Narayanan, H., Seidler, T., Luna, M. F., Sokolov, M., Morbidelli, M., & Butté, A. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462248 · Cited by 73
“The implementation and performance of the hybrid modeling framework are also demonstrated for a set of experimental data reported by Feidl et al. [15].”
InfluentialSelf-citationIntegration and digitalization in the manufacturing of therapeutic proteins
Narayanan, H., Sponchioni, M., & Morbidelli, M. (2021) · Chemical Engineering Science · doi:10.1016/j.ces.2021.117159 · Cited by 67
Self-citation
Metadata
- Authors
- Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A.
- Affiliations
- ETH Zurich (CH)
- Merck Serono S.A. (Switzerland) (CH)
- Corresponding author
- Butté, Alessandro
- Venue
- Processes
- Publisher
- MDPI AG
- Published
- 2019-10-01
- Volume
- 7
- Issue
- 10
- Pages
- 683
- ISSN
- 2227-9717 (ISSN-L)
- OpenAlex
- W2978951492
- Cited by
- 46
- References
- 40
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 8 · 2023: 7 · 2022: 3 · 2021: 9 · 2020: 8
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Processes (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Conicet (submittedVersion, cc-by)
- Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
- ETH Zürich Research Collection (cc-by)
- Funders
- KTI Program of the Swiss Economic Ministry (19190.2 PFIW-IW)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- monoclonal antibody purification, Raman spectroscopy, extended Kalman filter, lumped kinetic model, state estimation, real-time process monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.