The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ISFET Based Microsensors for Environmental Monitoring
Open accessAbstract
The use of microsensors for in-field monitoring of environmental parameters is gaining interest due to their advantages over conventional sensors. Among them microsensors based on semiconductor technology offer additional advantages such as small size, robustness, low output impedance and rapid response. Besides, the technology used allows integration of circuitry and multiple sensors in the same substrate and accordingly they can be implemented in compact probes for particular applications e.g., in situ monitoring and/or on-line measurements. In the field of microsensors for environmental applications, Ion Selective Field Effect Transistors (ISFETs) have a special interest. They are particularly helpful for measuring pH and other ions in small volumes and they can be integrated in compact flow cells for continuous measurements. In this paper the technologies used to fabricate ISFETs and a review of the role of ISFETs in the environmental field are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Research works printed but not linked: 92
- Bergveld, 2003, Thirty Years of ISFETOLOGY—What Happened in the Past 30 Years and What May Happen in the Next 30 Years, Sens. Actuat. B-Chem, 88, 1, 10.1016/S0925-4005(02)00301-5 · DOI · Paper page
- Janata, 1994, 20 Years of Ion-Selective Field-Effect Transistors, Analyst, 119, 2275, 10.1039/an9941902275 · DOI
- Sibbald, 1983, Chemical-Sensitive Field-Effect Transistors, IEEE Proc.-I Comm. Speech, 130, 233
- Bergveld, P., Sibbald, A., and Svehla, G. (1988). Analytical and Biomedical Applications of Ion-Selective Field-Effect Transistors, Elsevier Science.
- Shiramizu, 1979, Ion-Selective Field-Effect Transistors with Heterogeneous Membranes, Anal. Chim. Acta, 108, 161, 10.1016/S0003-2670(01)93052-1 · doi:10.1016/s0003-2670(01)93052-1
- Janata, J., Huber, R.J., and Freiser, H. (1978). Ion-Selective Electrodes in Analytical Chemistry, Plenum Press.
- Moss, 1975, Potassium Ion-Sensitive Field-Effect Transistor, Anal. Chem, 47, 2238, 10.1021/ac60363a005 · DOI · Paper page
- 1994, Universal Approach for the Fabrication of Ca2+, K+ and NO3− Sensitive Membrane ISFETs, Sens. Actuat. B-Chem, 18, 200, 10.1016/0925-4005(94)87084-5 · doi:10.1016/0925-4005(94)87084-5
- Bratov, 1995, Photocurable Polymer Matrices for Potassium-Sensitive Ion-Selective Electrode Membranes, Anal. Chem, 67, 3589, 10.1021/ac00115a032 · doi:10.1021/ac00115a032
- Munoz, 1997, Photosensitive polyurethanes applied to the development of CHEMFET and ENFET devices for biomedical sensing, Biosens. Bioelectron, 12, 577, 10.1016/S0956-5663(96)00081-4 · DOI
- Kolytcheva, 1999, Influence of the organic matrix on the properties of membrane coated ion sensor field-effect transistors, Sens. Actuat. B-Chem, 58, 456, 10.1016/S0925-4005(99)00126-4 · doi:10.1016/s0925-4005(99)00126-4
- Grimes, 2006, ISFET Based Sensors: Fundamentals and Applications, Encyclopedia of Sensors, 5, 151
- Alegret, 1993, ISFET-Based Urea Biosensor, Sens. Actuat. B-Chem, 16, 453, 10.1016/0925-4005(93)85227-2 · doi:10.1016/0925-4005(93)85227-2
- Chandler, 1990, An ISFET-Based Flow-Injection Analysis System for Determination of Urea - Experiment and Theory, Sens. Actuat. B-Chem, 1, 433, 10.1016/0925-4005(90)80244-T · doi:10.1016/0925-4005(90)80244-t
- Jimenez, 1997, Use of photopolymerizable membranes based on polyacrylamide hydrogels for enzymatic microsensor construction, Anal. Chim. Acta, 351, 169, 10.1016/S0003-2670(97)00332-2 · DOI
- Caras, 1985, pH-Based Enzyme Potentiometric Sensors. 2. Glucose-Sensitive Field-Effect Transistor, Anal. Chem, 57, 1920, 10.1021/ac00286a028 · DOI
- Caras, 1985, pH-Based Enzyme Potentiometric Sensors. 3. Penicillin-Sensitive Field-Effect Transistor, Anal. Chem, 57, 1924, 10.1021/ac00286a029 · DOI
- Chi, 2000, Study on Separative Structure of EnFET to Detect Acetylcholine, Sens. Actuat. B-Chem, 71, 68, 10.1016/S0925-4005(00)00606-7 · DOI
- Jimenez, 1999, Polyurethane-Acrylate Photocurable Polymeric Membrane for Ion-Sensitive Field-Effect Transistor Based Urea Biosensors, Anal. Chim. Acta, 389, 179, 10.1016/S0003-2670(99)00157-9 · DOI
- Alegret, 1992, Flow-through pH-ISFET + Reference-ISE as Integrated Detector in Automated FIA Determinations, Sens. Actuat. B-Chem, 7, 555, 10.1016/0925-4005(92)80363-3 · doi:10.1016/0925-4005(92)80363-3
- Izquierdo, 1995, Ion-Sensitive Field-Effect Transistors and Ion-Selective Electrodes as Sensors in Dynamic-Systems, Electroanalysis, 7, 505, 10.1002/elan.1140070602 · DOI
- Ruzicka, 2000, Flow injection analysis, Anal. Chem., 72, 212A, 10.1021/ac002756m · doi:10.1021/ac002756m
- Bergveld, 2000, Bedside Clinical Chemistry: From Catheter Tip Sensor Chips Towards Micro Total Analysis Systems, Biomed. Microdevices, 2, 185, 10.1023/A:1009976328558 · doi:10.1023/a:1009976328558
- Jeanneret, 1993, Modular Setup for a Miniaturized Chemical-Analysis System, Sens. Actuat. B-Chem, 15, 211, 10.1016/0925-4005(93)85053-D · doi:10.1016/0925-4005(93)85053-d
- Bratov, 1995, Photocurable Polymers Applied as Encapsulating Materials for ISFET Production, Sens. Actuat. B-Chem, 25, 823, 10.1016/0925-4005(95)85183-6 · doi:10.1016/0925-4005(95)85183-6
- Chovelon, 1992, Sensitization of Dielectric Surfaces by Chemical Grafting—Application to pH ISFETs and REFETs, Sens. Actuat. B-Chem, 8, 221, 10.1016/0925-4005(92)85021-N · DOI
- Chudy, 1999, Towards REFET, Sens. Actuat. B-Chem, 57, 47, 10.1016/S0925-4005(99)00134-3 · DOI
- Matsuo, 1978, Characteristics of Parylene Gate ISFET, J. Electrochem. Soc, 125, C121
- Huang, 2002, Fabrication and Characterization of a New Planar Solid-State Reference Electrode for ISFET Sensors, Thin Solid Films, 406, 255, 10.1016/S0040-6090(01)01783-7 · doi:10.1016/s0040-6090(01)01783-7
- Zaborowski, M., Jaroszewicz, B., Tomaszewski, D., Prokaryn, P., Malinowska, E., Grygolowicz-Pawlak, E., and Grabiec, P. (2007, January June). Fabrication of MOS-compatible ion-sensitive devices for water pollution monitoring (warmer). Ciechocinek, Poland. · doi:10.1109/mixdes.2007.4286208
- Ewald, 1990, Technology for Backside Contacted pH-Sensitive ISFETs Embedded in a p-Well Structure, Sens. Actuat. B-Chem, 1, 335, 10.1016/0925-4005(90)80225-O · doi:10.1016/0925-4005(90)80225-o
- Merlos, 1995, Application of Nickel Electroless Plating to the Fabrication of Low-Cost Backside Contact ISFETs, Sens. Actuat. B-Chem, 27, 336, 10.1016/0925-4005(94)01613-M · doi:10.1016/0925-4005(94)01613-m
- Sakai, 1990, A Backside Contact ISFET with a Silicon-Insulator-Silicon Structure, Sens. Actuat. B-Chem, 1, 341, 10.1016/0925-4005(90)80226-P · doi:10.1016/0925-4005(90)80226-p
- Kloeck, 1988, A pH-ISFET and an Integrated pH-Pressure Sensor with Back-Side Contacts, Sens. Actuat, 14, 165, 10.1016/0250-6874(88)80063-5 · DOI
- Merlos, 1995, New Technology for Easy and Fully IC-Compatible Fabrication of Backside-Contacted ISFETs, Sens. Actuat. B-Chem, 24, 228, 10.1016/0925-4005(95)85049-X · doi:10.1016/0925-4005(95)85049-x
- Poghossian, 1993, Method of Fabrication of ISFETs and CHEMFETs on an Si-SiO2-Si Structure, Sens. Actuat. B-Chem, 14, 653, 10.1016/0925-4005(93)85130-3 · DOI
- Yagi, 1993, Rear-Gate ISFET with A Membrane Locking Structure Using an Ultrahigh Concentration Selective Boron-Diffusion Technique, Sens. Actuat. B-Chem, 13, 212, 10.1016/0925-4005(93)85364-G · doi:10.1016/0925-4005(93)85364-g
- Cane, 1997, Microtechnologies for pH ISFET Chemical Sensors, Microelectron. J, 28, 389, 10.1016/S0026-2692(96)00068-7 · DOI
- Codinachs, 2008, Integrated Multisensor for FIA-Based Electronic Tongue Applications, IEEE Sens. J, 8, 608, 10.1109/JSEN.2008.918965 · DOI
- Akiyama, 1982, Ion-Sensitive Fiel-Effect Transistors with Inorganic Gate Oxide for pH Sensing, IEEE T. Electron Dev, 29, 1936, 10.1109/T-ED.1982.21054 · DOI
- Kimura, 1986, An Integrated SOS/FET Multi-Biosensor, Sens. Actuat, 9, 373, 10.1016/0250-6874(86)80069-5 · DOI
- Chin, 2001, A Novel pH Sensitive ISFET with on Chip Temperature Sensing Using CMOS Standard Process, Sens. Actuat. B-Chem, 76, 582, 10.1016/S0925-4005(01)00639-6 · DOI
- Lauwers, 2001, A CMOS Multiparameter Biochemical Microsensor with Temperature Control and Signal Interfacing, IEEE J. Solid-St. Circ, 36, 2030, 10.1109/4.972154 · doi:10.1109/4.972154
- Wong, 1989, A CMOS-Integrated ISFET-Operational Amplifier Chemical Sensor Employing Differential Sensing, IEEE T. Electron. Dev, 36, 479, 10.1109/16.19957 · DOI
- Yeow, 1997, A Very Large Integrated pH-ISFET Sensor Array Chip Compatible with Standard CMOS Processes, Sens. Actuat. B-Chem, 44, 434, 10.1016/S0925-4005(97)00207-4 · DOI
- Martinoia, 2001, Development of ISFET Array-Based Microsystems for Bioelectrochemical Measurements of Cell Populations, Biosens. Bioelectron, 16, 1043, 10.1016/S0956-5663(01)00202-0 · DOI
- Neuzil, 1995, ISFET Integrated Sensor Technology, Sens. Actuat. B-Chem, 24, 232, 10.1016/0925-4005(95)85050-3 · doi:10.1016/0925-4005(95)85050-3
- Tsukada, 1989, Platinum-Platinum Oxide Gate pH-ISFET, Jpn. J. Appl. Phys, 28, 2450, 10.1143/JJAP.28.2450 · doi:10.1143/jjap.28.2450
- Bausells, 1999, Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology, Sens. Actuat. B-Chem, 57, 56, 10.1016/S0925-4005(99)00135-5 · DOI · Paper page
- Bousse, 1988, A Process for the Combined Fabrication of Ion Sensors and CMOS Circuits, IEEE Electron Device Lett, 9, 44, 10.1109/55.20408 · DOI
- Jakobson, 2002, Ion-Sensistive Field-Effect Transistor in Standard CMOS Fabricated Post Processing, IEEE Sens. J, 2, 279, 10.1109/JSEN.2002.802237 · DOI
- Baumann, 1999, Microelectronic Sensor System for Microphysiological Application on Living Cells, Sens. Actuat. B-Chem, 55, 77, 10.1016/S0925-4005(99)00116-1 · DOI
- Campanella, 1995, Sensitive Membrane ISFETs for Nitrate Analysis in Waters, Sens. Actuat. B-Chem, 27, 329, 10.1016/0925-4005(94)01612-L · doi:10.1016/0925-4005(94)01612-l
- Wakida, 2001, Studies on pH and Nitrate Checkers Made of Semiconductor Devices for Acid Rain Monitoring, Water Air Soil Poll, 130, 625, 10.1023/A:1013888224702 · doi:10.1023/a:1013888224702
- Poghossian, 2001, Application of ISFETs for pH Measurement in Rain Droplets, Sens. Actuat. B-Chem, 76, 634, 10.1016/S0925-4005(01)00659-1 · DOI
- Humenyuk, 2006, Development of pNH4-ISFETs Microsensors for Water Analysis, Microelectron. J, 37, 475, 10.1016/j.mejo.2005.09.024 · doi:10.1016/j.mejo.2005.09.024
- Launay, 2004, Study of Front-Side Connected Chemical Field Effect Transistor for Water Analysis, Microelectron. Reliab, 44, 443, 10.1016/j.microrel.2003.10.001 · doi:10.1016/j.microrel.2003.10.001
- Ruzicka, 1978, Flow Injection Analysis. 10. Theory, Techniques and Trends, Anal. Chim. Acta, 99, 37, 10.1016/S0003-2670(01)84498-6 · DOI · Paper page
- Bratov, 2005, Chemical Multi-Sensor Arrays for Liquids Monolithic Integration Using Microelectronic Technology, Defense Against Bioterror: Detection Technologies, Implementation Strategies and Commercial Opportunities, 1, 273, 10.1007/1-4020-3384-2_21 · doi:10.1007/1-4020-3384-2_21
- Alegret, 1991, Flow-through Ph-ISFET as Detector in Automated Determinations, Electroanalusis, 3, 349, 10.1002/elan.1140030417 · doi:10.1002/elan.1140030417
- Alegret, 1990, Flow-through pH-ISFET as Detector in the Determination of Ammonia, Anal. Chim. Acta, 231, 53, 10.1016/S0003-2670(00)86396-5 · doi:10.1016/s0003-2670(00)86396-5
- Jimenez, 1996, Continuous-Flow System for on Line Water Monitoring Using Back Side Contact ISFET-Based Sensors, Anal. Chem, 68, 3801, 10.1021/ac9603946 · DOI
- Cambiaso, 1996, An H+-FET-Based System for On-Line Detection of Microorganisms in Waters, Sens. Actuat. B-Chem, 34, 245, 10.1016/S0925-4005(97)80004-4 · doi:10.1016/s0925-4005(97)80004-4
- Chung, D.W.Y., Tsai, Y.L., Liu, T.T., Leu, C.L., Yang, C.H., Pijanowska, D.G., Torbicz, W., Grabiec, P.B., and Jaroszewicz, B. (2007, January April). Analog Processor Design for Potentiometric Sensor Array and Its Applications in Smart Living Space—Art. No. 65760W. Orlando, FL, USA. · doi:10.1117/12.725196
- Chung, W.Y., Chang, K.C., Hong, D.Y., Cheng, C., Cruza, F., Liu, T.S., Yang, C.H., Chiang, J.L., Pijanowska, D.G., Dawgul, M., Torbicz, W., Grabiec, P.B., and Jarosewicz, B. (2008, January July). An Electronic Tongue System Design Using Ion Sensitive Field Effect Transistors and Their Interfacing Circuit Techniques. Louisville, KY, USA. · doi:10.1109/ugim.2008.19
- Chen, 2008, An Intelligent ISFET Sensory System with Temperature and Drift Compensation for Long-Term Monitoring, IEEE Sens. J, 8, 1948, 10.1109/JSEN.2008.2006471 · DOI
- Campanella, 1997, New ISFET Devices for Environmental Analysis, Analusis, 25, 164
- Sanchez, 1999, Development of a New Ion-Selective Field-Effect Transistor Sensor for Anionic Surfactants: Application to Potentiometric Titrations, Anal. Chim. Acta, 382, 157, 10.1016/S0003-2670(98)00762-4 · doi:10.1016/s0003-2670(98)00762-4
- Janata, 1981, Chemically Sensitive Field-Effect Transistor to Detect Organophosphorous Compounds and Pesticides, Aviat. Space Environ. Med, 52, 666
- Campanella, 1996, Organophosphorus Pesticide (Paraoxon) Analysis Using Solid State Sensors, Sens. Actuat. B-Chem, 33, 25, 10.1016/0925-4005(96)01909-0 · DOI
- Colapicchioni, 1992, Fabrication and Characterization of ENFET Devices for Biomedical Applications and Environmental Monitoring, Sens. Actuat. B-Chem, 6, 202, 10.1016/0925-4005(92)80056-4 · doi:10.1016/0925-4005(92)80056-4
- Hendji, 1993, Sensitive Detection of Pesticides Using a Differential ISFET-Based System with Immobilized Cholinesterases, Anal. Chim. Acta, 281, 3, 10.1016/0003-2670(93)85333-F · doi:10.1016/0003-2670(93)85333-f
- Ristori, 1996, Potentiometric detection of pesticides in water samples, Anal. Chim. Acta, 325, 151, 10.1016/0003-2670(96)00023-2 · doi:10.1016/0003-2670(96)00023-2
- Flores, 2003, Development of an EnFET for the Detection of Organophosphorous and Carbamate Insecticides, Anal. Bioanal. Chem, 376, 476, 10.1007/s00216-003-1925-y · doi:10.1007/s00216-003-1925-y
- Senillou, 1999, ISFET Microsensors for the Detection of Pollutants in Liquid Media, Sens. Actuat. B-Chem, 59, 154, 10.1016/S0925-4005(99)00213-0 · DOI
- Orozco, 2007, Portable system based on microsensors for environmental monitoring applications, Meas. Sci. Technol, 18, 935, 10.1088/0957-0233/18/3/048 · doi:10.1088/0957-0233/18/3/048
- Dieffenbach, 2000, In situ soil solution chemistry in the rhizosphere of mature Norway spruce (Picea abies [L.] Karst.) trees, Plant Soil, 222, 149, 10.1023/A:1004755404412 · doi:10.1023/a:1004755404412
- Artigas, 2001, Application of ion sensitive field effect transistor based sensors to soil analysis, Comput. Electron. Ag, 31, 281, 10.1016/S0168-1699(00)00187-3 · DOI
- Artigas, 2001, Development of a Photopolymerisable Membrane for Calcium Ion Sensors—Application to Soil Drainage Waters, Anal. Chim. Acta, 426, 3, 10.1016/S0003-2670(00)01146-6 · doi:10.1016/s0003-2670(00)01146-6
- Beltran, 2002, Development of Durable Nitrate-Selective Membranes for All-Solid State ISE and ISFET Sensors Based on Photocurable Compositions, Electroanalysis, 14, 213, 10.1002/1521-4109(200202)14:3<213::AID-ELAN213>3.0.CO;2-U · doi:10.1002/1521-4109(200202)14:3<213::aid-elan213>3.0.co;2-u
- Rossel, 2004, Rapid, Quantitative and Spatial Field Measurements of Soil pH Using an Ion Sensitive Field Effect Transistor, Geoderma, 119, 9, 10.1016/S0016-7061(03)00219-2 · DOI
- Gieling, 2005, ISE and CHEMFET Sensors in Greenhouse Cultivation, Sens. Actuat. B-Chem, 105, 74, 10.1016/S0925-4005(04)00113-3 · doi:10.1016/s0925-4005(04)00113-3
- Verkerk, 1992, Multiion Sensing Device for Horticultural Application Based upon Chemical Modification and Special Packaging of ISFETs, Sens. Actuat. B-Chem, 6, 34, 10.1016/0925-4005(92)80027-U · doi:10.1016/0925-4005(92)80027-u
- Birrell, 2001, Real-time multi ISFET/FIA soil analysis system with automatic sample extraction, Comput. Electron. Agric, 32, 45, 10.1016/S0168-1699(01)00159-4 · DOI
- Price, 2003, Rapid nitrate analysis of soil cores using ISFETs, T. ASAE, 46, 601, 10.13031/2013.13588 · doi:10.13031/2013.13588
- Fernandez, 2001, Pore Water Chemistry of the Febex Bentonite, Mater. Res. Soc. Symp. Proc, 663, 573, 10.1557/PROC-663-573 · doi:10.1557/proc-663-573
- Fernandez, 2001, Analysis of squeezed pore waters as a function of the applied pressure in Opalinus Clay material (Switzerland), Water-Rock Interact, 10, 1323
- Fernandez, 2004, Analysis of the Porewater Chemical Composition of a Spanish Compacted Bentonite Used in an Engineered Barrier, Phys. Chem. Earth, 29, 105, 10.1016/j.pce.2003.12.001 · DOI · Paper page
- Wang, 2004, Sorption and Desorption of Radiostrontium on Powdered Bentonite: Effect of pH and Fulvic Acid, J. Radioanal. Nuc. Chem, 261, 497, 10.1023/B:JRNC.0000037088.34650.0e · DOI
- Motellier, 1995, pH Determination of Clay Interstitial Water Using A Fiberoptic Sensor, Sens. Actuat. B-Chem, 29, 345, 10.1016/0925-4005(95)01705-4 · doi:10.1016/0925-4005(95)01705-4
- Orozco, 2006, Monitoring of bentonite pore water with a probe based on solid-state microsensors, Anal. Chim. Acta, 579, 95, 10.1016/j.aca.2006.07.030 · DOI
- Jimenez, 2003, Development of a Multiparametric System Based on Solid-State Microsensors for Monitoring a Nuclear Waste Repository, Sens. Actuat. B-Chem, 91, 103, 10.1016/S0925-4005(03)00073-X · doi:10.1016/s0925-4005(03)00073-x
Cited by
Biosensing based on field-effect transistors (FET): Recent progress and challenges
Sadighbayan, D., Hasanzadeh, M., & Ghafar-Zadeh, E. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116067 · Cited by 305
Jang, H.-J., & Cho, W.-J. (2014) · Scientific Reports · doi:10.1038/srep05284 · Cited by 103
Jang, H.-J., Gu, J.-G., & Cho, W.-J. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.02.056 · Cited by 76
Metadata
- Authors
- Jimenez-Jorquera, C., Orozco, J., & Baldi, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2009-12-24
- Volume
- 10
- Issue
- 1
- Pages
- 61-83
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2106018048
- Cited by
- 184
- References
- 1
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ISFET Based Microsensors for Environmental Monitoring. https://app.cochat.ai/papers/10.3390/s100100061
- The paper
- Jimenez-Jorquera, C., Orozco, J., & Baldi, A. (2009). ISFET Based Microsensors for Environmental Monitoring. Sensors. https://doi.org/10.3390/s100100061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.