The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Microfabricated Reference Electrodes and their Biosensing Applications
Open accessAbstract
Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of Electrochemistry of the Elements
Bard, A. J., & Ketelaar, J. A. A. (1974) · Journal of The Electrochemical Society · doi:10.1149/1.2402383 · Cited by 2,064
Cation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
(1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90546-2 · Cited by 778
Surface micromachining for microelectromechanical systems
Bustillo, J. M., Howe, R. T., & Muller, R. S. (1998) · Proceedings of the IEEE · doi:10.1109/5.704260 · Cited by 644
The absolute potential of the standard hydrogen electrode: a new estimate
Reiss, H., & Heller, A. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100266a013 · Cited by 430
Direct Detection of the Hybridization of Synthetic Homo-Oligomer DNA Sequences by Field Effect
Souteyrand, E., Cloarec, J. P., Martin, J. R., Wilson, C., Lawrence, I., Mikkelsen, S., & Lawrence, M. F. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963056h · Cited by 340
Tables of standard electrode potentials
Steyermark, A. (1981) · Microchemical Journal · doi:10.1016/0026-265x(81)90021-7 · Cited by 309
Covington, A. K., Bates, R. G., & Durst, R. A. (1985) · Pure and Applied Chemistry · doi:10.1351/pac198557030531 · Cited by 301
Waleed Shinwari, M., Jamal Deen, M., & Landheer, D. (2007) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 268
Self-citationAg/AgCl microelectrodes with improved stability for microfluidics
Polk, B. J., Stelzenmuller, A., Mijares, G., MacCrehan, W., & Gaitan, M. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.03.121 · Cited by 246
A physical model for drift in pH ISFETs
Jamasb, S., Collins, S., & Smith, R. L. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00040-9 · Cited by 239
Kita, H. (1966) · Journal of The Electrochemical Society · doi:10.1149/1.2423772 · Cited by 236
Patolsky, F., Zayats, M., Katz, E., & Willner, I. (1999) · Analytical Chemistry · doi:10.1021/ac9901541 · Cited by 234
DNA electrochemical biosensors
Mascini, M., Palchetti, I., & Marrazza, G. (2001) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160000629 · Cited by 204
Landheer, D., Aers, G., McKinnon, W. R., Deen, M. J., & Ranuarez, J. C. (2005) · Journal of Applied Physics · doi:10.1063/1.2008354 · Cited by 163
Self-citationSuzuki, H., Shiroishi, H., Sasaki, S., & Karube, I. (1999) · Analytical Chemistry · doi:10.1021/ac990437t · Cited by 162
Suzuki, H. R., Hiratsuka, A., Sasaki, S., et al. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00043-4 · Cited by 149
Carbon nanotube biosensors: The critical role of the reference electrode
Minot, E. D., Janssens, A. M., Heller, I., Heering, H. A., Dekker, C., & Lemay, S. G. (2007) · Applied Physics Letters · doi:10.1063/1.2775090 · Cited by 148
Noise considerations in field-effect biosensors
Deen, M. J., Shinwari, M. W., Ranuárez, J. C., & Landheer, D. (2006) · Journal of Applied Physics · doi:10.1063/1.2355542 · Cited by 147
Self-citationMoussy, F. G., & Harrison, D. J. (1994) · Analytical Chemistry · doi:10.1021/ac00077a015 · Cited by 144
Glucose biosensor based on multi-wall carbon nanotubes and screen printed carbon electrodes
Guan, W., Yu, L., Chen, Y., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.030 · Cited by 132
A Practical Reference Electrode
Giner, J. (1964) · Journal of The Electrochemical Society · doi:10.1149/1.2426125 · Cited by 132
Screen-printed reference electrodes for potentiometric measurements
Tymecki, Ł., Zwierkowska, E., & Koncki, R. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.056 · Cited by 130
Schwarz, M. A., Galliker, B., Fluri, K., Kappes, T., & Hauser, P. C. (2001) · The Analyst · doi:10.1039/b007383k · Cited by 122
Covington, A. K., Bates, R. G., & Durst, R. A. (1983) · Pure and Applied Chemistry · doi:10.1351/pac198355091467 · Cited by 110
Nolan, M. A., Tan, S. H., & Kounaves, S. P. (1997) · Analytical Chemistry · doi:10.1021/ac961020f · Cited by 102
All-solid-state planar miniature ion-selective chloride electrode
Zielińska, R., Mulik, E., Michalska, A., Achmatowicz, S., & Maj‐Żurawska, M. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01407-6 · Cited by 95
The electrochemical formation and reduction of a thick AgCl deposition layer on a silver substrate
Jin, X., Lu, J., Liu, P., & Tong, H. (2003) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(02)01474-2 · Cited by 92
Reference Electrode for Ionic Liquids
Saheb, A. H., Janata, J., & Josowicz, M. A. (2006) · Electroanalysis · doi:10.1002/elan.200503435 · Cited by 85
Matsumoto, T., Ohashi, A., & Ito, N. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00334-3 · Cited by 78
The Use of the Glass Electrode in Biochemistry
Kerridge, P. M. T. (1925) · Biochemical Journal · doi:10.1042/bj0190611 · Cited by 66
An iridium oxide reference electrode for use in microfabricated biosensors and biochips
Yang, H., Kang, S. K., Choi, C. A., Kim, H., Shin, D.-H., Kim, Y. S., & Kim, Y. T. (2004) · Lab on a Chip · doi:10.1039/b309899k · Cited by 66
Simonis, A., Luth, H., Wang, J., & Schöning, M. J. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.04.072 · Cited by 64
Fedirko, N., Svichar, N., & Chesler, M. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00258.2006 · Cited by 60
An Analytical Technique for Counteracting Drift in Ion-Selective Field Effect Transistors (ISFETs)
Jamasb, S. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.833148 · Cited by 58
An integrated module for sensing pO2, pCO2, and pH
Suzuki, H. R., Hirakawa, T., Sasaki, S., & Karube, I. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00748-5 · Cited by 54
A Self‐Contained Miniature Hydrogen Reference Electrode
Will, F. G. (1986) · Journal of The Electrochemical Society · doi:10.1149/1.2108600 · Cited by 53
Potentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes
Cui, G., Lee, J. S., Kim, S. J., Nam, H., Cha, G. S., & Kim, H. D. (1998) · The Analyst · doi:10.1039/a802872i · Cited by 53
Label‐free detection of DNA using field‐effect transistors
Ingebrandt, S., & Offenhäusser, A. (2006) · physica status solidi (a) · doi:10.1002/pssa.200622465 · Cited by 49
Hydrogen-selective microelectrodes based on silicon needles
Zine, N., Bausells, J., Ivorra, A., Aguiló, J., Zabala, M., Teixidor, F., Masalles, C., Viñas, C., & Errachid, A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00069-8 · Cited by 42
Miniature liquid junction reference electrode with micromachined silicon cavity
Yee, S. S., Jin, H. J., & Lam, L. K. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)81504-x · Cited by 41
Advances in the manufacturing, types, and applications of biosensors
Ravindra, N. M., Prodan, C., Fnu, S., et al. (2007) · JOM · doi:10.1007/s11837-007-0150-0 · Cited by 38
Kim, D., Park, H., Jung, H.-M., Shin, J., Choi, P., Lee, J., & Lim, G. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.3855 · Cited by 37
Kim, H. R., Kim, Y. D., Kim, K. I., Shim, J. H., Nam, H., & Kang, B. K. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.09.010 · Cited by 34
Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology
Simonis, A., Dawgul, M., Luth, H., & Schöning, M. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2005.04.063 · Cited by 33
Hiratsuka, A., Ikebukuro, K., Karube, I., Kojima, K., Suzuki, H. R., & Muguruma, H. (2001) · The Analyst · doi:10.1039/b008036p · Cited by 32
A bio-FET sensor for lactose based on co-immobilized β-galactosidase/glucose dehydrogenase
Sevilla, F. B., III, Kullick, T., & Scheper, T. H. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80024-3 · Cited by 26
Developing the self-contained hydrogen reference electrode
Gong, S., Lu, J., & Yan, H. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00345-8 · Cited by 22
A micromachined surface work-function gas sensor for low-pressure oxygen detection
Bergstrom, P. L., Patel, S. V., Schwank, J. W., et al. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80336-x · Cited by 21
Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays
Franklin, R. K., Johnson, M. D., Scottt, K. A., Shim, J. H., Nam, H., Kipket, D. R., & Brown, R. B. (2005) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2005.1597971 · Cited by 18
BioFET sensor for detection of albumin in urine
Park, K., Lee, S., Sohn, Y.-S., & Choi, S.-H. (2008) · Electronics Letters · doi:10.1049/el:20083551 · Cited by 16
Surface micromachined PDMS microfluidic devices fabricated using a sacrificial photoresist
Subramani, B. G., & Selvaganapathy, P. R. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/1/015013 · Cited by 13
Self-citationMicrofabricated iridium oxide reference electrode for continuous glucose monitoring sensor
Yang, H., Kang, S. K., Shin, D.-H., Kim, H., & Kim, Y. T. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1215263 · Cited by 7
Jamasb, S., Collins, S. D., & Smith, R. L. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758833 · Cited by 7
Design of a Silicon Based Amperometric Microbiosensor Involving NAD-Dependent Dehydrogenase
Tap, H., Gros, P., & Gué, A. M. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199909)11:13<945::aid-elan945>3.0.co;2-7 · Cited by 5
Cited by
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
EGFET-Based Sensors for Bioanalytical Applications: A Review
Pullano, S. A., Critello, C. D., Mahbub, I., Tasneem, N. T., Shamsir, S., Islam, S. K., Greco, M., & Fiorillo, A. S. (2018) · Sensors · doi:10.3390/s18114042 · Cited by 197
Wang, S., Wu, Y., Gu, Y., Li, T., Luo, H., Li, L.-H., Bai, Y., Li, L., Liu, L., Cao, Y., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01560 · Cited by 174
Metadata
- Authors
- Shinwari, M. W., Zhitomirsky, D., Deen, I. A., Selvaganapathy, P. R., Deen, M. J., & Landheer, D.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-03-02
- Volume
- 10
- Issue
- 3
- Pages
- 1679-1715
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2079109852
- Cited by
- 333
- References
- 56
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.