Cited by 29Flow Measurement and AnalysisSensor Technology and Measurement SystemsGas Sensing Nanomaterials and Sensors

High Accuracy Acoustic Relative Humidity Measurement inDuct Flow with Air

Open access
Schaik, Wilhelm van, Grooten, Mart, Wernaart, Twan, Geld, Cees van der·2010·Sensors

Abstract

An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s100807421

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Ultrasonic sensor performance can be degraded via vehicle corner error, temperature variation and relative humidity, false echoes caused by turbulence, and acoustic or electric noise.

    “Ultrasonic sensor performance can be degraded via vehicle corner error [16], temperature variation and relative humidity [17], false echoes caused by turbulence [18], and acoustic or electric noise [19].”

    From Sensor-Based Prognostic Health Management of Advanced Driver Assistance System for Autonomous Vehicles: A Recent Survey (2022) · cites this paper as [17]

    Citation [17] is attached to temperature variation and relative humidity, not the other listed errors. The Introduction says both affect the speed of sound, and Dynamic Response says temperature fluctuations can delay or distort the acoustic humidity measurement. The paper uses changes in relative humidity as the quantity to be measured; it does not establish that humidity itself degrades sensor performance. (LLM, conf=0.82)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Schaik, W. V., Grooten, M., Wernaart, T., & Geld, C. V. D.
Affiliations
  • Van Schaik Innovation Handling B.V., Glaslaan 2, Building SWA 1.032, 5616 LW, Eindhoven, The Netherlands
  • Eindhoven University of Technology (NL)
Corresponding author
Geld, Cees van der
Venue
Sensors
Publisher
MDPI AG
Published
2010-08-09
Volume
10
Issue
8
Pages
7421-7433
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2147141062
Cited by
29
References
13
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 7 · 2021: 2 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 3 · 2013: 1 · 2012: 1
FWCI
1.52
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TU/e Research Portal (submittedVersion, other-oa)
  • TU/e Research Portal (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Technische Universiteit Eindhoven
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Flow Measurement and Analysis
  • Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
Keywords
ultrasonic transducers, duct flow, steam-air mixture, gas velocity measurement, temperature measurement, humidity sensor calibration, dynamic response, non-intrusive sensing
MeSH terms
Acoustics, Air, Calibration, Equipment Design, Gases, Humidity, Temperature, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review