A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for portable physiological applications. The ultrathin InN epilayer extensively enhances sensing sensitivity due to its strong electron accumulation on roughly 5–10 nm deep layers from the surface. Platinum as catalyst can increase output current signals by 2.5-fold (94 vs. 37.5 μA) as well as reduce response time by 8.4-fold (150 vs. 1,260 s) in comparison with bare InN. More, the effect of 3% oxygen consumption due to breath inhalation and exhalation on 2.4 ppm acetone gas detection was investigated, indicating that such an acetone concentration can be analyzed in air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon Nanotube Sensors for Gas and Organic Vapor Detection
Li, J., Lu, Y., Ye, Q., Cinke, M., Han, J., & Meyyappan, M. (2003) · Nano Letters · doi:10.1021/nl034220x · Cited by 1,810 · cited 1×
“, (porous) silicon [12], carbon (nanotubes) [13]), Group II-VI (i.”
Murray, R. K. (1998) · Medical Entomology and Zoology · Cited by 905
Indium nitride (InN): A review on growth, characterization, and properties
Bhuiyan, A. G., Hashimoto, A., & Yamamoto, A. (2003) · Journal of Applied Physics · doi:10.1063/1.1595135 · Cited by 848 · cited 1×
“57 × 10(13) cm) for the InN films grown on AlN film on a buffer layer [34,35].”
BackgroundDeng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590 · cited 1×
“8 ppm [6].”
The diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399 · cited 1×
“healthy human beings [1].”
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357 · cited 3×
“, metal oxides [14–17]) and Group III-V (i.”
BackgroundMicromachined nanocrystalline silver doped SnO2 H2S sensor
Gong, J., Chen, Q., Lian, M.-R., Liu, N.-C., Stevenson, R. G., & Adami, F. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.04.035 · Cited by 191 · cited 1×
“Humidity and many gas in human breath was reported to affect the measurement of gas sensors [38,39]; commercial solutions are available to minimize humidity effects [40].”
BackgroundDissociative adsorption of molecular hydrogen on silicon surfaces
Dürr, M., & Höfer, U. (2006) · Surface Science Reports · doi:10.1016/j.surfrep.2006.08.002 · Cited by 177 · cited 1×
“87 eV also can be found in other studies [36].”
ResultControlled Growth and Sensing Properties of In2O3 Nanowires
Vomiero, A., Bianchi, S., Comini, E., Faglia, G., Ferroni, M., & Sberveglieri, G. (2007) · Crystal Growth & Design · doi:10.1021/cg070209p · Cited by 136 · cited 3×
“In2O3 [15] Resistance (voltage)”
BackgroundMurade, P. A., -, V. S. S., Chaudhari, G. N., Kapse, V. D., & Bajpeyee, A. U. (2010) · Current Applied Physics · doi:10.1016/j.cap.2010.08.020 · Cited by 127
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Nanomaterial-Based Sensors for Detection of Disease by Volatile Organic Compounds
Broza, Y. Y., & Haick, H. (2013) · Nanomedicine · doi:10.2217/nnm.13.64 · Cited by 358
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
Nanostructured Metal Oxide-Based Acetone Gas Sensors: A Review
Amiri, V., Roshan, H., Mirzaei, A., Neri, G., & Ayesh, A. I. (2020) · Sensors · doi:10.3390/s20113096 · Cited by 287
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Breath acetone as a potential marker in clinical practice
Ruzsányi, V., & Péter Kalapos, M. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa66d3 · Cited by 195
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105
“Kun-WeiKao, et al. used a gas sensor made of Indium Nitride ( InN ) of 10 nm thickness [41].”
Method
Metadata
- Authors
- Kao, K.-W., Hsu, M.-C., Chang, Y.-H., Gwo, S., & Yeh, J. A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2012-05-29
- Volume
- 12
- Issue
- 6
- Pages
- 7157-7168
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2088967198
- Cited by
- 158
- References
- 17
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.