CoChat

A Review of Protocol Implementations and Energy Efficient Cross-Layer Design for Wireless Body Area Networks

Open access
Hughes, Laurie, Wang, Xinheng, Chen, Tao · 2012 · Sensors

The DOI matches its Crossref record; 106 of the 107 references it cites were found in a registry or an index.

Abstract

The issues inherent in caring for an ever-increasing aged population has been the subject of endless debate and continues to be a hot topic for political discussion. The use of hospital-based facilities for the monitoring of chronic physiological conditions is expensive and ties up key healthcare professionals. The introduction of wireless sensor devices as part of a Wireless Body Area Network (WBAN) integrated within an overall eHealth solution could bring a step change in the remote management of patient healthcare. Sensor devices small enough to be placed either inside or on the human body can form a vital part of an overall health monitoring network. An effectively designed energy efficient WBAN should have a minimal impact on the mobility and lifestyle of the patient. WBAN technology can be deployed within a hospital, care home environment or in the patient’s own home. This study is a review of the existing research in the area of WBAN technology and in particular protocol adaptation and energy efficient cross-layer design. The research reviews the work carried out across various layers of the protocol stack and highlights how the latest research proposes to resolve the various challenges inherent in remote continual healthcare monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s121114730

Cites

106 of 106 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. WBAN positioning.
Figure 1. WBAN positioning.CC BY · PubMed Central
Figure 2. WBAN consisting of various wireless biosensors.
Figure 2. WBAN consisting of various wireless biosensors.CC BY · PubMed Central
Figure 3. Typical WBAN architecture.
Figure 3. Typical WBAN architecture.CC BY · PubMed Central
Figure 4. Simplified ZigBee/802.15.4 protocol stack.
Figure 4. Simplified ZigBee/802.15.4 protocol stack.CC BY · PubMed Central
Figure 5. IEEE 802.15.6 high level architecture.
Figure 5. IEEE 802.15.6 high level architecture.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 2

  1. IEEE Standards Association 802.15.6-2012 IEEE Standards for Local and Metropolitan Area Networks–Part 15.6: Wireless Body Area Networks Available online: http://standards.ieee.org/findstds/standard/802.15.6-2012.html (accessed on 20 May 2012)
  2. Lin H. Campbell G. Using DQRAP (Distributed Queuing Random Access Protocol) for Local Wireless Communications Proceedings of Wireless' 93 Calgary, AB, Canada 12–14 July 1993 625 635

Cited by

See all 72

Metadata

Authors
Hughes, L., Wang, X., & Chen, T.
Affiliations
  • Swansea University (GB)
  • University of the West of Scotland (GB)
  • Chigoo Interactive Technologies Ltd, Wuxi 214028, China
Corresponding author
Wang, Xinheng
Venue
Sensors
Publisher
MDPI AG
Published
2012-11-02
Volume
12
Issue
11
Pages
14730-14773
ISSN
1424-8220 (ISSN-L)
OpenAlex
W1992189487
Cited by
71
References
107
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 1 · 2019: 7 · 2018: 4 · 2017: 10 · 2016: 11 · 2015: 5 · 2014: 11 · 2013: 2
FWCI
0.50
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Engineering and Physical Sciences Research Council (EP/E024734/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Biomedical Engineering › Molecular Communication and Nanonetworks
  • Physical Sciences › Computer Science › Computer Networks and Communications › Wireless Sensor Networks for Data Analysis
Keywords
wireless body area networks, energy efficiency, cross-layer design, protocol adaptation, wireless sensor networks, remote patient monitoring, e-health, healthcare monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.