Whole-cell biosensors are a good alternative to enzyme-based biosensors since they offer the benefits of low cost and improved stability. In recent years, live cells have been employed as biosensors for a wide range of targets. In this review, we will focus on the use of microorganisms that are genetically modified with the desirable outputs in order to improve the biosensor performance. Different methodologies based on genetic/protein engineering and synthetic biology to construct microorganisms with the required signal outputs, sensitivity, and selectivity will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Reprogramming bacteria to seek and destroy an herbicide
Sinha, J., Reyes, S. J., & Gallivan, J. P. (2010) · Nature Chemical Biology · doi:10.1038/nchembio.369 · Cited by 166 · cited 1×
“proteins [50,52–54].”
RetractedQUORUM SENSING: Cell-to-Cell Communication in Bacteria
Waters, C. M., & Bassler, B. L. (2005) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.21.012704.131001 · Cited by 3,979 · cited 1×
“Quorum sensing typically involves a strong intercellular coupling over tens of micrometers [68], yet the relatively slow diffusion time of molecular communication leads to signal delays over the millimeter length scale.”
BackgroundMicrobial pathogenesis in cystic fibrosis: mucoid Pseudomonas aeruginosa and Burkholderia cepacia
Govan, J. R. W., & Deretic, V. P. (1996) · Microbiological Reviews · doi:10.1128/mmbr.60.3.539-574.1996 · Cited by 1,812 · cited 1×
“Pathogens such as Pseudomonas aeruginosa and Burkholderia cepacia employ diffusible AHL signal molecules to regulate the production of a number of virulence determinants and can cause destructive lung diseases in cystic fibrosis patients [64].”
BackgroundStochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
A biosensor that uses ion-channel switches
Cornell, B. A., Braach-Maksvytis, V. L. B., King, L. G., Osman, P. D. J., Raguse, B., Wieczorek, L., & Pace, R. J. (1997) · Nature · doi:10.1038/42432 · Cited by 1,117 · cited 1×
“In nature, single-molecule detection is routinely achieved through ligand-gated ion channel proteins [76].”
BackgroundMicrobial biosensors: A review
Su, L., Jia, W., Hou, C., & Lei, Y. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.005 · Cited by 725 · cited 5×
“Optical techniques are based on the measurement of fluorescent, luminescent, colorimetric, or other optical outputs from microorganisms [7].”
BackgroundInfluentialGalloway, W. R. J. D., Hodgkinson, J. T., Bowden, S. D., Welch, M., & Spring, D. R. (2011) · Chemical Reviews · doi:10.1021/cr100109t · Cited by 665 · cited 1×
“Conventionally, autoinducers have been divided into two generic groups: the acyl homoserine lactones (AHLs), used by Gram-negative bacteria and the autoinducing polypeptides (AIPs), used by Gram-positive bacteria [61].”
BackgroundWhere microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Microbial whole-cell sensing systems of environmental pollutants
Belkin, S. (2003) · Current Opinion in Microbiology · doi:10.1016/s1369-5274(03)00059-6 · Cited by 518 · cited 1×
“Live microorganisms have been employed as biosensors using different sensing techniques such as electrochemical and optical detection [10–13].”
MethodDaunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445 · cited 2×
“external toxicants, or communication signals [10,11].”
Background
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Engineered living biomaterials
Rodrigo-Navarro, A., Sankaran, S., Dalby, M. J., del Campo, A., & Salmeron-Sanchez, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00350-8 · Cited by 494
Hara, T. O., & Singh, B. (2021) · ACS ES&T Water · doi:10.1021/acsestwater.0c00125 · Cited by 252
Bereza-Malcolm, L. T., Mann, G., & Franks, A. E. (2015) · ACS Synthetic Biology · doi:10.1021/sb500286r · Cited by 219
Bober, J. R., Beisel, C. L., & Nair, N. U. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121019 · Cited by 168
Microbial Fuel Cell-Based Biosensors
Cui, Y., Lai, B., & Tang, X. (2019) · Biosensors · doi:10.3390/bios9030092 · Cited by 167
“These can be overcome by whole-cell based biosensors, and thus they are often considered as future alternatives to enzymatic biosensors [12,13].”
BackgroundNext‐Generation Probiotics: From Traditional Strains to Personalized Therapeutics
Jadhav, N. K., Magdum, A. B., Shinde, K. V., & Nimbalkar, M. S. (2026) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.70339 · Cited by 29
Dual carbon sequestration with photosynthetic living materials
Dranseike, D., Cui, Y., Ling, A. S., Donat, F., Bernhard, S., Bernero, M., Areeckal, A., Qin, X.-H., Oakey, J. S., Dillenburger, B., et al. (2023) · doi:10.1101/2023.12.22.572991 · Cited by 3
Metadata
- Authors
- Park, M., Tsai, S.-L., & Chen, W.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-05-06
- Volume
- 13
- Issue
- 5
- Pages
- 5777-5795
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2133145868
- Cited by
- 220
- References
- 71
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.