Leg edema quantification for heart failure patients via 3D imaging
Open accessAbstract
Heart failure is a common cardiac disease in elderly patients. After discharge, approximately 50% of all patients are readmitted to a hospital within six months. Recent studies show that home monitoring of heart failure patients can reduce the number of readmissions. Still, a large number of false positive alarms as well as underdiagnoses in other cases require more accurate alarm generation algorithms. New low-cost sensors for leg edema detection could be the missing link to help home monitoring to its breakthrough. We evaluated a 3D camera-based measurement setup in order to geometrically detect and quantify leg edemas. 3D images of legs were taken and geometric parameters were extracted semi-automatically from the images. Intra-subject variability for five healthy subjects was evaluated. Thereafter, correlation of 3D parameters with body weight and leg circumference was assessed during a clinical study at the Medical University of Graz. Strong correlation was found in between both reference values and instep height, while correlation in between curvature of the lower leg and references was very low. We conclude that 3D imaging might be a useful and cost-effective extension of home monitoring for heart failure patients, though further (prospective) studies are needed.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Newer optical scanners utilize non-contact depth sensing methods to create advanced 3D images for determining changes in leg shape, size, and consistency.
“Newer optical scanners utilize non‐contact depth sensing methods to create advanced 3D images for determining changes in leg shape, size, and consistency. 81”
From Prioritizing symptom management in the treatment of chronic heart failure (2020) · cites this paper as [81]
The State-of-the-Art section says optical 3D scanners use non-contact depth sensing, and the Measurement Setup describes extracting leg geometry from 3D images. The paper supports assessing changes in leg shape and size, but our copy does not describe using these images to determine leg consistency. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Epidoxorubicin In, A., Cascinu, S., Labianca, R., Barone, C., Santoro, O., Carnaghi, C., Frontini, L., Aitini, E., Rota, S., Torri, V., et al. (2009) · Springer eBooks · doi:10.1007/978-0-387-78665-0_6514 · Cited by 1,394 · see citing works
Michel Komajda, N. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00700-5 · Cited by 1,217 · see citing works
Readmission After Hospitalization for Congestive Heart Failure Among Medicare Beneficiaries
Krumholz, H. M. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440220103013 · Cited by 821 · see citing works
Decision Making in Advanced Heart Failure
Allen, L. A., Stevenson, L. W., Grady, K. L., Goldstein, N. E., Matlock, D. D., Arnold, R. M., Cook, N. R., Felker, G. M., Francis, G. S., Hauptman, P. J., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31824f2173 · Cited by 818 · see citing works
Rehospitalization for Heart Failure
Desai, A. S., & Stevenson, L. W. (2012) · Circulation · doi:10.1161/circulationaha.112.125435 · Cited by 616 · see citing works
Scherr, D., Kästner, P., Kollmann, A., Hallas, A., Auer, J., Krappinger, H., Schuchlenz, H. W., Stark, G., Grander, W., Jakl, G., et al. (2009) · Journal of Medical Internet Research · doi:10.2196/jmir.1252 · Cited by 279 · see citing works
Self-citationA systematic review of the literature on home monitoring for patients with heart failure
Martínez, A., Everss, E., Rojo-Álvarez, J. L., Figal, D. P., & García-Alberola, A. (2006) · Journal of Telemedicine and Telecare · doi:10.1258/135763306777889109 · Cited by 133 · see citing works
Measuring impedance in congestive heart failure: Current options and clinical applications
Tang, W. H. W., & Tong, W. S. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.10.016 · Cited by 119 · see citing works
A new method for the 3D measurement of postoperative swelling following orthognathic surgery
Kau, C. H., Cronin, A. J., Durning, P., Zhurov, A. I., Sandham, A., & Richmond, S. (2006) · Orthodontics and Craniofacial Research · doi:10.1111/j.1601-6343.2006.00341.x · Cited by 116 · see citing works
Primary Results of the HABIT Trial (Heart Failure Assessment With BNP in the Home)
Maisel, A. S., Barnard, D. D., Jaski, B. E., Frivold, G., Marais, J., Azer, M., Miyamoto, M. I., Lombardo, D. M., Kelsay, D., Borden, K., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.052 · Cited by 98 · see citing works
Rana, M., Gellrich, N., Joos, U., Piffkò, J., & Kater, W. (2011) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2011.02.015 · Cited by 75 · see citing works
Water displacement leg volumetry in clinical studies - A discussion of error sources
Rabe, E., Stücker, M., & Ottillinger, B. (2010) · BMC Medical Research Methodology · doi:10.1186/1471-2288-10-5 · Cited by 53 · see citing works
Innovative telemonitoring system for cardiology: from science to routine operation
Morak, J., Modre, R., Kollmann, A., Ebner, C., Fruhwald, F. M., Schreier, G., & Kästner, P. (2010) · Applied Clinical Informatics · doi:10.4338/aci-2009-12-ra-0021 · Cited by 36 · see citing works
Self-citationSegmental Bioimpedance for Measuring Amlodipine-Induced Pedal Edema: A Placebo-Controlled Study
Schoeller, D. A., Alon, A., Manekas, D., Mixson, L. A., Lasseter, K. C., Noonan, G. P., Bolognese, J. A., Heymsfield, S. B., Beals, C. R., & Nunes, I. (2012) · Clinical Therapeutics · doi:10.1016/j.clinthera.2012.01.018 · Cited by 12 · see citing works
Sensitivity of whole-body bioelectrical impedance to edema in one leg
Codognotto, M., Piccoli, A., Piazza, M., & Frigatti, P. (2007) · Springer eBooks · doi:10.1007/978-3-540-73841-1_204 · Cited by 1 · see citing works
Flagged first, then by citations
4 of the 19 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- [17]Elbischger P. Jerolitsch-Binder J. Prasser M. Menard C. Ein neuartiges Messsystem zur Exakten und effizienten Ermittlung des Extremitätenvolumnes Proceedings of the eHealth 2011 Vienna, Austria 26–27 May 2011 Schreier G. Hayn D. Ammenwerth E. OCG Vienna, Austria 2011 129 134 Available online: http://www.ehealth20xx.at/eHealth2011/papers/antonitsch.pdf (accessed on 12 June 2013)
Cited by
Sorted by citations
Prioritizing symptom management in the treatment of chronic heart failure
Koshy, A. O., Gallivan, E. R., McGinlay, M., Straw, S., Drozd, M., Toms, A. G., Gierula, J., Cubbon, R. M., Kearney, M. T., & Witte, K. K. (2020) · ESC Heart Failure · doi:10.1002/ehf2.12875 · Cited by 66 · see citing works
“Newer optical scanners utilize non-contact depth sensing methods to create advanced 3D images for determining changes in leg shape, size, and consistency.(81) Hence, novel approaches to oedema monitoring are needed to build a model of disease progression and facilitate patient-directed diuretic dose adjustment, balanc…”
MethodSmartSock: A wearable platform for context-aware assessment of ankle edema
Fallahzadeh, R., Pedram, M., & Ghasemzadeh, H. G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592169 · Cited by 36 · see citing works
Evaluation of the Accuracy of a Video and AI Solution to Measure Lower Leg and Foot Volume
Chausiaux, O., Williams, G., Nieznański, M., Bagdu, A., Downer, P., Keyser, M., & Husheer, S. (2021) · Medical Devices Evidence and Research · doi:10.2147/mder.s297713 · Cited by 10 · see citing works
Volumetric assessment of lower limb oedema using 3D laser scanning technique: a systematic review
Bahadori, S., Immins, T., & Wainwright, T. W. (2021) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2021.1970841 · Cited by 8 · see citing works
Methods of ex vivo analysis of tissue status in vascularized composite allografts
Ton, C., Salehi, S., Abasi, S., Aggas, J. R., Liu, R., Brandacher, G., Guiseppi‐Elie, A., & Grayson, W. L. (2023) · Journal of Translational Medicine · doi:10.1186/s12967-023-04379-x · Cited by 5 · see citing works
Nanjo, T., Asano, Y., Kawase, Y., & Tao, S. (2022) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2605340 · Cited by 1 · see citing works
Wearable fringing field capacitive sensor for subcutaneous edema quantification
Su, G.-L., Sung, Y., Lin, T., Huang, K., & Wang, T.-W. (2025) · Measurement · doi:10.1016/j.measurement.2025.119518
Takashima, A., Eguchi, Y., SANADA, K., Kurabayashi, D., Shirogane, S., Masaki, S., & Ogata, T. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11251856
Lippi, L., Nascimben, M., Turco, A., Refati, F., Michelis, V. D., Alessandro de, S. I. R. E., Invernizzi, M., & Rimondini, L. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1750128
Autofocus-Based Optimization of Trajectory Filtering for Close-Range ISAR Imaging
Mergenthaler, P., Künzle, C., Froehlich, A.-C., Ullmann, I., & Vossiek, M. (2026) · IEEE Radar Conference (RadarConf) · doi:10.1109/radarconf2663773.2026.11674968
- Authors
- Hayn, D., Fruhwald, F., Riedel, A., Falgenhauer, M., & Schreier, G.
- Affiliations
- AIT Austrian Institute of Technology GmbH (AT)
- Medical University of Graz (AT)
- Corresponding author
- Hayn, Dieter
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-08-14
- Volume
- 13
- Issue
- 8
- Pages
- 10584-10598
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC3812619
- OpenAlex
- W2046547922
- Cited by
- 10
- References
- 19
- Citations by year
- 2026: 2 · 2025: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2016: 1
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- heart failure, lower limb edema, edema quantification, 3D imaging, home monitoring, remote patient monitoring, 3D camera, geometric parameters, leg circumference, body weight, false positive alerts, hospital readmission, low-cost sensors
- MeSH terms
- Adult, Algorithms, Artificial Intelligence, Edema, Heart Failure, Humans, Image Interpretation, Computer-Assisted, Leg, Male, Sensitivity and Specificity, Reproducibility of Results, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review