A wearable system for gait training in subjects with Parkinson's disease
Open accessThe DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index; none of the 28 sources its claims cite is checked for support yet.
Abstract
In this paper, a system for gait training and rehabilitation for Parkinson's disease (PD) patients in a daily life setting is presented. It is based on a wearable architecture aimed at the provision of real-time auditory feedback. Recent studies have, in fact, shown that PD patients can receive benefit from a motor therapy based on auditory cueing and feedback, as happens in traditional rehabilitation contexts with verbal instructions given by clinical operators. To this extent, a system based on a wireless body sensor network and a smartphone has been developed. The system enables real-time extraction of gait spatio-temporal features and their comparison with a patient's reference walking parameters captured in the lab under clinical operator supervision. Feedback is returned to the user in form of vocal messages, encouraging the user to keep her/his walking behavior or to correct it. This paper describes the overall concept, the proposed usage scenario and the parameters estimated for the gait analysis. It also presents, in detail, the hardware-software architecture of the system and the evaluation of system reliability by testing it on a few subjects.
Overview
CoChat Summary
## TL;DR
The paper presents a fully portable, wearable closed-loop gait training system for people with Parkinson’s disease that uses IMUs plus a smartphone to compute gait features in real time and return vocal feedback. It reports preliminary validation on multiple PD patients and reliability checks showing real-time operation, with step-length estimation agreeing closely with instrumented walkway measurements.
## Key findings
- The system was designed around three sensors and one smartphone: two sensors on the shoes and one on the trunk, with vocal feedback delivered via headphones.
- In step-length validation, five male PD patients performed nine trials each on an 8.80-meter instrumented GAITRite walkway; the paper reports a bias close to zero and standard deviation within 3% for stride duration and 2% for stride length.
- The sensing and orientation components were compared against commercial or MATLAB reference implementations: the node’s static-noise comparison with an Xsens platform showed very similar performance, and orientation estimation error versus MATLAB was reported as RMSE lower than 0.004 degrees for roll, pitch, and yaw; a second comparison reported RMSE of 1.818, 0.594, and 2.941 degrees for the three estimated angles.
- The Android application was tested on different dual-core smartphones and achieved real-time performance; on an LG Nexus 5, the main operations took 0.11 ms per new sample and 0.23 ms per new detected step.
## Methods
- The paper describes a patient-specific closed-loop gait training system built on a wireless body sensor network with IMUs and an Android smartphone for real-time processing and feedback.
- For clinical validation of step-length estimation, five male PD patients walked at comfortable, increased, and decreased speeds over an 8.80-meter GAITRite walkway, while two foot-mounted IMUs streamed data at 200 Hz.
- The analysis included real-time gait-event detection (initial contact and foot-off), ZUPT-aided inertial navigation for step-length estimation, and Bland–Altman plots to compare IMU-derived stride duration and length with GAITRite measurements.
## Limitations
- The paper explicitly notes that the system was evaluated only on a few subjects, and that it is now being used for pilot trials with PD patients rather than already established for extensive clinical use.
- The authors state that further analysis is desirable to validate the spatio-temporal feature estimation.
- Evident from the text: the validation sample for step-length accuracy was small (five male PD patients), and the paper also reports one case where a subject produced accelerations above the IMU full scale (±6 g), indicating a hardware range limitation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
0 Valid · 0 Not valid · 17 Not checked · 17 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The results are in Table 2, and they show a very similar performance for the two platforms, reporting the standard deviations of each axis for the three sensors.”
§ A Wearable System for Gait Training in Subjects with Parkinson's Disease > System Architecture > Sensing Nodes Calibration and On-Board Orientation Estimate
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“It is used only when advantageous, since we found that for high transmission rates, the Sniff mode uses more energy than the normal operating mode [24].”
§ A Wearable System for Gait Training in Subjects with Parkinson's Disease > System Architecture > Power Management
What the sources say
- Not checked yetcites [24] Casamassima, F., Farella, E., and Benini, L. (2013, January 9–11). Power saving policies for multipurpose WBAN. Karlsruhe, Germany. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Feedback is returned to the user in form of vocal messages, encouraging the user to keep her/his walking behavior or to correct it.”
§ A Wearable System for Gait Training in Subjects with Parkinson's Disease > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The difference between the orientation computed on the two platforms is negligible, having an RMSE lower than 0.004 degrees for roll, pitch and yaw angles.”
§ A Wearable System for Gait Training in Subjects with Parkinson's Disease > System Architecture > Sensing Nodes Calibration and On-Board Orientation Estimate
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This new algorithm is able to determine IC and FO by processing the angular velocity signal arising along the medio-lateral axis of the foot.”
§ A Wearable System for Gait Training in Subjects with Parkinson's Disease > Algorithms and Real-Time Feedback for Gait Rehabilitation > Soft Real-Time Gait Events Detection
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
11 more claims
Create a free account to see all 34 claims and to verify the 28 references still open.
- It may state two separate claims as one. 13
- Probably not a substantial claim. 6
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Technical features and algorithms were first validated for the detection of gait abnormalities against standard gait registration systems [26]”
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751 · cited 1×
“State-of-the-art algorithms for the estimation of orientation from IMU sensor data were optimized for the EXLs1 sensor node, including the Kalman filter [30], its extended variation [31] and recently developed complementary filters [32,33].”
MethodGait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068 · cited 1×
“State-of-the-art algorithms for the estimation of orientation from IMU sensor data were optimized for the EXLs1 sensor node, including the Kalman filter [30], its extended variation [31] and recently developed complementary filters [32,33].”
MethodNonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751 · cited 1×
“State-of-the-art algorithms for the estimation of orientation from IMU sensor data were optimized for the EXLs1 sensor node, including the Kalman filter [30], its extended variation [31] and recently developed complementary filters [32,33].”
MethodPedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399 · cited 1×
“…is an unfeasible operation, since the orientation-dependent gravitational component is not straightforwardly separable from the inertial acceleration, and even minor drift internal to the gyroscope or the accelerometer (being single-/double-integrated) causes errors that increase cubically [39].”
BackgroundA survey of design techniques for system-level dynamic power management
Benini, L., Bogliolo, A., & De Micheli, G. (2000) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/92.845896 · Cited by 1,241 · cited 1×
“The scheduling protocol is defined taking into account the application’s sampling rate requirements and the cost of the transitions between the different power states [23].”
BackgroundAided Navigation: GPS with High Rate Sensors
Farrell, J. A. (2008) · Cited by 776
The pathogenesis of gait hypokinesia in Parkinson's disease
Morris, M. E., Iansek, R., Matyas, T. A., & Summers, J. J. (1994) · Brain · doi:10.1093/brain/117.5.1169 · Cited by 709 · cited 1×
“In addition, patients show problems in maintaining rhythmicity and the amplitude of the gait [11,12].”
BackgroundFisher, B. E., Wu, A. D., Salem, G. J., Song, J., Lin, C.-H. (., Yip, J., Cen, S., Gordon, J., Jakowec, M., & Petzinger, G. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.01.013 · Cited by 474 · cited 2×
“Although the rates of motor learning may be slower in PD, recent evidence highlights that PD patients can acquire motor skills and improve their motor performance with sustained personalized training [5,6,9].”
BackgroundImpaired regulation of stride variability in Parkinson's disease subjects with freezing of gait
Hausdorff, J. M., Schaafsma, J. D., Balash, Y., Bartels, A. L., Gurevich, T., & Giladi, N. (2003) · Experimental Brain Research · doi:10.1007/s00221-002-1354-8 · Cited by 442 · cited 1×
“PD gait is characterized by a difficulty with the internal regulation of stride length and step clearance and increased gait variability [1,10].”
Background
Cited by
Zhu, M., Shi, Q., He, T., Yi, Z., Ma, Y., Yang, B., Chen, T., & Lee, C. (2019) · ACS Nano · doi:10.1021/acsnano.8b08329 · Cited by 411
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[48] compared these two methods based on accuracy, computational cost, and energy efficiency and concluded that the Kalman filter-based method was their preferred choice.”
MethodPasluosta, C. F., Gassner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2461555 · Cited by 323
“Motion sensors attached to the patient’s body are used to quantify the effectiveness of new medication and rehabilitation therapies [32], [62], [102].”
BackgroundGinis, P., Nieuwboer, A., Dorfman, M., Ferrari, A., Gazit, E., Canning, C. G., Rocchi, L., Chiari, L., Hausdorff, J. M., & Mirelman, A. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2015.11.004 · Cited by 225
“2A in Supplementary Materials); 2) A menu of four training targets: cadence, stride length, symmetry and gait speed; 3) A ‘therapeutic window’ allowing calibration of feedback according to the individual's optimal gait performance [26], and set per gait parameter as a percentage above and below the median of every 5 s…”
BackgroundMethodSelf-citationAssessing Gait in Parkinson’s Disease Using Wearable Motion Sensors: A Systematic Review
Brognara, L., Palumbo, P., Grimm, B., & Palmerini, L. (2019) · Diseases · doi:10.3390/diseases7010018 · Cited by 189
Barth, J., Oberndorfer, C., Pasluosta, C., Schülein, S., Gassner, H., Reinfelder, S., Kugler, P., Schuldhaus, D., Winkler, J., Klucken, J., et al. (2015) · Sensors · doi:10.3390/s150306419 · Cited by 186
“Other studies [7–9] have used clearly defined signal characteristics like peaks or zero crossings in gyroscope and accelerometer data to determine gait events such as toe off, heel strike, and stance phase.”
BackgroundAnwary, A. R., Yu, H., & Vassallo, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2786587 · Cited by 175
“from literature accelerometer data [65], [66] and literature gyroscope data [67], [68] were compared to our gait cycle signal patterns ie the different phases labelled in Fig.”
ResultSystematic Review of Mobile Health Applications in Rehabilitation
Nussbaum, R., Kelly, C., Quinby, E., Mac, A., Parmanto, B., & Dicianno, B. E. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.07.439 · Cited by 156
Shahid, J., Kashif, A., & Shahid, M. K. (2023) · Brain Sciences · doi:10.3390/brainsci13050717 · Cited by 277
“Reported benefits have been shown when used as an adjunct to task-specific training [82].”
MethodA Validated Smartphone-Based Assessment of Gait and Gait Variability in Parkinson’s Disease
Ellis, R. J., Ng, Y. S., Zhu, S., Tan, D. M., Anderson, B., Schlaug, G., & Wang, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0141694 · Cited by 152
“Several previous methods for portable RAC delivery combined with gait analysis have been proposed [50,56,102 – 104]; all, however, have been designed around the use of footswitches or shoe-mounted IMUs to collect the gait data itself.”
Carpinella, I., Cattaneo, D., Bonora, G., Bowman, T., Martina, L., Montesano, A., & Ferrarin, M. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.11.003 · Cited by 158
Ferrari, A., Ginis, P., Hardegger, M., Casamassima, F., Rocchi, L., & Chiari, L. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2457511 · Cited by 140
“, in terms of step length, asymmetry or speed, acting as an intelligent tutoring systems [25].”
BackgroundMethodSelf-citationAn IMU-to-Body Alignment Method Applied to Human Gait Analysis
Vargas-Valencia, L., Elias, A., Rocon, E., Bastos-Filho, T., & Frizera, A. (2016) · Sensors · doi:10.3390/s16122090 · Cited by 116
Wearables for independent living in older adults: Gait and falls
Godfrey, A. (2017) · Maturitas · doi:10.1016/j.maturitas.2017.03.317 · Cited by 105
Milosevic, B., Leardini, A., & Farella, E. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00762-7 · Cited by 116
Self-citationMobile phone applications in Parkinson's disease: a systematic review
Rey, M. L.-D., Vela, L., & la Cuerda, R. C.-D. (2018) · Neurología (English Edition) · doi:10.1016/j.nrleng.2018.12.002 · Cited by 101
Smartphone-based systems for physical rehabilitation applications: A systematic review
Moral-Muñoz, J. A., Zhang, W., Cobo, M. J., Herrera‐Viedma, E., & KABER, D. B. (2019) · Assistive Technology · doi:10.1080/10400435.2019.1611676 · Cited by 89
“Consequently, all smartphone applications targeting Parkinson disease rehabilitation are focused on gait performance measurement and FOG detection, usually by placing IMU sensors at the feet of a patient (Casamassima et al., 2014; Ferrari et al., 2016; Ginis et al., 2016; Mazilu et al., 2015) or attaching a smartphone…”
BackgroundNguyen, H., Lebel, K., Bogard, S., Goubault, É., Boissy, P., & Duval, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2745418 · Cited by 88
“Effective patientcare through real-time feedback of rehabilitation [1], [2] and pharmaceutical intervention [3], [4] can help manage and improve the quality of life by minimizing the effects of these motor dysfunctions on daily living movement.”
BackgroundNguyen, H., Lebel, K., Boissy, P., Bogard, S., Goubault, É., & Duval, C. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0241-2 · Cited by 75
“Recently, much attention has been given to the use of body-worn sensors to monitor mobility [3–6] in an effort to improve patient care through real-time feedback of rehabilitation [7, 8] and pharmaceutical intervention [9], particularly in patients with Parkinson’s diseases (PD).”
BackgroundApplying Deep Learning to Stereotypical Motor Movement Detection in Autism Spectrum Disorders
Rad, N. M., & Furlanello, C. (2016) · IEEE ... International Conference on Data Mining workshops · doi:10.1109/icdmw.2016.0178 · Cited by 71
Aplicaciones móviles en la enfermedad de Parkinson: una revisión sistemática
Rey, M. L.-D., Vela, L., & Cano‐de‐la‐Cuerda, R. (2017) · Neurología · doi:10.1016/j.nrl.2017.03.006 · Cited by 85
“Dentro del tratamiento rehabilitador también se encontraría la apli-cación utilizada por van der Kolk et al. 37 , mediante la et al. 23 , Ferrari et al. 31 y Ginis et al. 41 se podría clasifi-car 28 carácter informativo sobre la EP.”
BackgroundWearable and wireless gait analysis platforms
Lemoyne, R. C., & Mastroianni, T. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100449-4.00006-3 · Cited by 67
Goyal, J., Khandnor, P., & Aseri, T. C. (2020) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2020.103955 · Cited by 71
Review—Emerging Portable Technologies for Gait Analysis in Neurological Disorders
Salchow-Hömmen, C., Skrobot, M., Jochner, M. C. E., Schauer, T., Kühn, A. A., & Wenger, N. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.768575 · Cited by 73
“For example, the gait training tool CuPiD-system consists of wearable IMUs, a smartphone, and headphones to deliver intelligent auditory feedback on gait (Casamassima et al., 2014; Ferrari et al., 2016).”
MethodGinis, P., Heremans, E., Ferrari, A., Bekkers, E. M. J., Canning, C. G., & Nieuwboer, A. (2017) · Journal of Neurology · doi:10.1007/s00415-017-8552-6 · Cited by 68
Self-citationA Systematic Survey of Research Trends in Technology Usage for Parkinson’s Disease
Deb, R., Bhat, G., An, S., Shill, H. A., & Ogras, U. Y. (2022) · Sensors · doi:10.3390/s22155491 · Cited by 60
Application of motor learning in neurorehabilitation: a framework for health-care professionals
Kleynen, M., Beurskens, A. J. H. M., Olijve, H., Kamphuis, J. F., & Braun, S. (2018) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2018.1483987 · Cited by 63
“Technologies that can provide patients with feedback even beyond regular therapy times are gaining increased interest (Casamassima et al., 2014; Shull et al., 2014).”
BackgroundGinis, P., Heremans, E., Ferrari, A., Dockx, K., Canning, C. G., & Nieuwboer, A. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00128 · Cited by 59
“The algorithm to obtain cadence from the feet raw data was described elsewhere (19) and validated for PD (30).”
BackgroundMethodSelf-citationHow Can Affect Be Detected and Represented in Technological Support for Physical Rehabilitation?
Olugbade, T., Singh, A., Bianchi‐Berthouze, N., Marquardt, N., Aung, M. H., & Williams, A. C. D. C. (2019) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3299095 · Cited by 50
Wearable training system with real-time biofeedback and gesture user interface
Umek, A., Tomažič, S., & Kos, A. (2015) · Personal and Ubiquitous Computing · doi:10.1007/s00779-015-0886-4 · Cited by 45
“In [19], a wearable system for gait training was demonstrated to provide persons with Parkinson’s disease with vocal feedback by encouraging them to maintain or correct their walking behaviour.”
BackgroundSuitability of Smartphone Inertial Sensors for Real-Time Biofeedback Applications
Kos, A., Tomažič, S., & Umek, A. (2016) · Sensors · doi:10.3390/s16030301 · Cited by 54
“In rehabilitation, accelerometers in smartphones are used to improve a person’s balance [7], for gait training of persons with Parkinson’s disease [19], for terminal exercise performance assessment [20], etc.”
MethodMeasuring Gait Quality in Parkinson’s Disease through Real-Time Gait Phase Recognition
Mileti, I., Germanotta, M., Sipio, E. D., Imbimbo, I., Pacilli, A., Erra, C., Petracca, M., Rossi, S., Prete, Z. D., Bentivoglio, A. R., et al. (2018) · Sensors · doi:10.3390/s18030919 · Cited by 50
“Assessment of gait impairments through spatio-temporal parameters is useful both in clinical and research settings [43,44].”
BackgroundPerez-Ibarra, J. C., Siqueira, A. A. G., & Krebs, H. I. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3011627 · Cited by 40
“In [28] and [29], authors used the dual-minima approach for identification of two gait events in PD subjects.”
BackgroundMultiple gait parameters derived from iPod accelerometry predict age-related gait changes
Kosse, N. M., Vuillerme, N., Hortobágyi, T., & Lamoth, C. J. C. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.02.022 · Cited by 41
Ferrari, A., Milletti, D., Giannini, G., Cevoli, S., Oppi, F., Palandri, G., Albini‐Riccioli, L., Mantovani, P., Anderlucci, L., Cortelli, P., et al. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0638-1 · Cited by 38
Self-citationGinis, P., Pirani, R., Basaia, S., Ferrari, A., Chiari, L., Heremans, E., Canning, C. G., & Nieuwboer, A. (2017) · Physiotherapy · doi:10.1016/j.physio.2017.05.001 · Cited by 40
Self-citationA Survey on Biofeedback and Actuation in Wireless Body Area Networks (WBANs)
Li, R., Lai, D. T. H., & Lee, W. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2738009 · Cited by 35
Anwary, A. R., Yu, H., Callaway, A. J., & Vassallo, M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3021501 · Cited by 36
“They were previously identified from accelerometer [23] and gyroscope [24] signals separately.”
BackgroundTang, J., Chen, Y. M., Li, K., Bai, Y., Guo, R., Fukuda, K., Someya, T., Ito, Y., & Kawamoto, M. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.163845 · Cited by 35
Inertial Motion Capture Costume Design Study
Szczęsna, A., Skurowski, P., Lach, E., Pruszowski, P., Pęszor, D., Paszkuta, M., Słupik, J., Łebek, K., Janiak, M., Polański, A., et al. (2017) · Sensors · doi:10.3390/s17030612 · Cited by 38
“For example [3] presents a system for gait training, and [16] describes a system for studying human postural stability onboard.”
BackgroundWearable Inertial Sensor for Jump Performance Analysis
Milosevic, B., & Farella, E. (2015) · Workshop on Wearable Systems and Applications (WearSys) · doi:10.1145/2753509.2753512 · Cited by 35
“Life and Medical Sciences Keywords: Wearable devices; Inertial Measurement Unit; Jump analysis; Counter-movement jump.”
BackgroundMethodSelf-citationKo, B.-W., Lee, H.-Y., & Song, W.-K. (2016) · Journal of Physical Therapy Science · doi:10.1589/jpts.28.1538 · Cited by 29
“In another study, Casamassima et al.14) described inertial measurement units (IMU) based on a wearable auditory feedback system that monitors gait training with Parkinson’s disease patients.”
BackgroundA Review of Recent Advances in Cognitive-Motor Dual-Tasking for Parkinson’s Disease Rehabilitation
Tan, X., Wang, K., Sun, W., Li, X., Wang, W., & Tian, F. (2024) · Sensors · doi:10.3390/s24196353 · Cited by 37
A Gait Analysis Approach to Track Parkinson's Disease Evolution Using Principal Component Analysis
de Medeiros, L. M., de Almeida, H. O., da Silva, L. D., Perkusich, M., & Fischer, R. (2016) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2016.14 · Cited by 27
“Physicians and physiotherapists apply gait analysis subjectively in clinical evaluation, which sometimes is followed by a survey regarding gait quality [1].”
BackgroundMethodEnergy-Efficient Context Aware Power Management with Asynchronous Protocol for Body Sensor Network
Magno, M., Polonelli, T., Casamassima, F., Gomez, A., Farella, E., & Benini, L. (2016) · Mobile Networks and Applications · doi:10.1007/s11036-016-0755-z · Cited by 30
Self-citationLiuzzi, P., Carpinella, I., Anastasi, D., Gervasoni, E., Lencioni, T., Bertoni, R., Carrozza, M. C., Cattaneo, D., Ferrarin, M., & Mannini, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-35744-x · Cited by 32
“Recently developed technologies based on portable devices already permit the acquisition and processing of data during unconstrained walking and provide results immediately following the recording 56 or even in real-time 57, 58 .”
Jiménez, N. J. V., Junior, A. G. L., Avellar, L. M., Vargas-Valencia, L., Rodríguez, P. E. C., Ramírez-Duque, A. A., Lyra, M., Marques, C., Bastos-Filho, T., & Frizera, A. (2019) · Electronics · doi:10.3390/electronics8020173 · Cited by 26
Gondim, I. T. G. D. O., de Souza, C. D. C. B., Rodrigues, M. A. B., Azevedo, I. M., Coriolano, M. D. G. W. D. S., & Lins, O. G. (2020) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2020.104097 · Cited by 30
MonParLoc: A Speech-Based System for Parkinson’s Disease Analysis and Monitoring
Alonso, D. P., Meléndez-Morales, G., López-Arribas, A., Lázaro-Carrascosa, C., Gómez-Rodellar, A., & Gómez‐Vilda, P. (2020) · IEEE Access · doi:10.1109/access.2020.3031646 · Cited by 28
Junior, A. G. L., Vargas-Valencia, L., dos Santos, W. M., Schneider, F. B. A., Siqueira, A. A. G., Pontes, M. J., & Frizera, A. (2018) · Optical Fiber Technology · doi:10.1016/j.yofte.2018.04.012 · Cited by 23
Ferrari, A., Milletti, D., Palumbo, P., Giannini, G., Cevoli, S., Magelli, E., Albini‐Riccioli, L., Mantovani, P., Cortelli, P., Chiari, L., et al. (2022) · Fluids and Barriers of the CNS · doi:10.1186/s12987-022-00350-y · Cited by 21
Self-citationMileti, I., Germanotta, M., Alcaro, S., Pacilli, A., Imbimbo, I., Petracca, M., Erra, C., Sipio, E. D., Aprile, I. G., Rossi, S., et al. (2017) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985910 · Cited by 21
“Despite the high interest in the development of wearable solutions for gait monitoring in PD [4], [5], [15], [16], a limited number of wearable solutions have been tested on data acquired during the OFF period.”
BackgroundZhou, Q., Zhang, H., Lari, Z., Liu, Z., & El‐Sheimy, N. (2016) · Sensors · doi:10.3390/s16101752 · Cited by 21
“Filippo [24] proposes a system that is able to provide real-time computation of gait features, and feeds back to the user in the purpose of helping him/her execute the most effective gait pattern.”
BackgroundA Survey on Energy Efficient Wireless Sensor Networks for Bicycle Performance Monitoring Application
Gharghan, S. K., Nordin, R., & Ismail, M. B. (2014) · Journal of Sensors · doi:10.1155/2014/153604 · Cited by 21
“[65] Bluetooth Android mobile phone based on Bluetooth, microcontroller based on ARM Cortex-M3, and accelerometer, gyroscope and magnetometer sensors N/A (i) Steps per minute (ii) Step length (iii) Gait speed (iv) Gait asymmetry (v) Trunk flexion (vi) Clearance 29.”
BackgroundPignolo, L., Basta, G., Carozzo, S., Bilotta, M., Todaro, M. R., Serra, S., Ciancarelli, I., Tonin, P., & Cerasa, A. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.09.020 · Cited by 29
Carpinella, I., Bertoni, R., Anastasi, D., Cardini, R., Lencioni, T., Ferrarin, M., Cattaneo, D., & Gervasoni, E. (2024) · Sensors · doi:10.3390/s24227284 · Cited by 16
Aich, S., Sain, M., Park, J., Choi, K.-W., & Kim, H. (2017) · International Conference on Inventive Computing and Informatics (ICICI) · doi:10.1109/icici.2017.8365398 · Cited by 17
“We have collected abstracts from 46 recent papers related to PD [ 9-56 9-56 We have collected abstracts from 47 recent papers related to PD.”
BackgroundImbesi, S., Corzani, M., Lopane, G., Mincolelli, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22218095 · Cited by 18
“[23] developed a wearable sensor and smartphonebased system that provided the same IntFB described above to improve the dynamic balance and gait performance of people with PD.”
Jie, L.-J., Jamin, G., Smit, K., Beurskens, A. J. H. M., & Braun, S. (2019) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2019.1629654 · Cited by 16
Insole-based Real-time Gait Analysis: Feature Extraction and Classification
Anwary, A. R., Arifoğlu, D., Jones, M., Vassallo, M., & Bouchachia, H. (2021) · IEEE International Symposium on Inertial Sensors and Systems (INERTIAL) · doi:10.1109/inertial51137.2021.9430482 · Cited by 15
Sofigait—A Wireless Inertial Sensor-Based Gait Sonification System
Linnhoff, D., Ploigt, R., & Mattes, K. (2022) · Sensors · doi:10.3390/s22228782 · Cited by 12
Imbesi, S., & Corzani, M. (2023) · Sensors · doi:10.3390/s23020874 · Cited by 13
“Vuzix Blade®Upgraded Version.”
MethodInfluentialFerrari, A., Ginis, P., Nieuwboer, A., Greenlaw, R., Muddiman, A., & Chiari, L. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-39601-9_22 · Cited by 14
Self-citationBao, T., Gao, J., Wang, J., Yang, C., Xu, F., Qiao, G., & Li, F. (2023) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1265543 · Cited by 20
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_7 · Cited by 11
IoT-Based COVID-19 Diagnosing and Monitoring Systems: A Survey
Anjum, N., Alibakhshikenari, M., Rashid, J., Jabeen, F., Asif, A., Mohamed, E. M., & Falcone, F. (2022) · IEEE Access · doi:10.1109/access.2022.3197164 · Cited by 12
“Similarly, it is revealed by the authors in [70] that progression in ‘‘Parkinson’s Disease’’ can be monitored very efficiently when utilizing wearable sensors in combination with vision based cameras.”
BackgroundLemoyne, R. C., & Mastroianni, T. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519418500057 · Cited by 11
Rosario, M. B. D., Lovell, N. H., & Redmond, S. J. (2019) · Sensors · doi:10.3390/s19132845 · Cited by 11
Corzani, M., Ferrari, A., Ginis, P., Nieuwboer, A., & Chiari, L. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2019.00265 · Cited by 13
Self-citationLinnhoff, D., Alizadeh, S., Schaffert, N., & Mattes, K. (2020) · Journal of Motor Learning and Development · doi:10.1123/jmld.2019-0028 · Cited by 18
Nackaerts, E., Nieuwboer, A., & Farella, E. (2017) · Parkinson s Disease · doi:10.1155/2017/9198037 · Cited by 11
Self-citationLow-cost real-time motion capturing system using inertial measurement units
Salicone, S., Corbellini, S., Jetti, H. V., & Ronaghi, S. (2022) · ACTA IMEKO · doi:10.21014/acta_imeko.v11i3.1290 · Cited by 8
Towards a portable human gait analysis & monitoring system
Kumar, S., Gopinath, K., Rocchi, L., Sukumar, P. T., Kulkarni, S., & Sampath, J. S. (2018) · IEEE International Conference on Signals and Systems (ICSigSys) · doi:10.1109/icsigsys.2018.8372660 · Cited by 11
“The result is used be used by doctors and surgeons for different purpose such as, to find the underlying cause of an abnormal gait [12], [13], rehabilitation of subjects suffering from motor related diseases such as Parkinson’s disease or Cerebral Palsy [16], [4], [14], improving the athletic performance of sports per…”
MethodInfluentialSelf-citationImbesi, S., Corzani, M., Petrocchi, F., Lopane, G., Chiari, L., & Mincolelli, G. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-79763-8_42 · Cited by 8
Porta, F. L., Lullini, G., Caselli, S., Valzania, F., Mussi, C., Tedeschi, C., Pioli, G., Bondavalli, M., Bertolotti, M., Banchelli, F., et al. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.943918 · Cited by 11
Attitudes towards a sensor-feedback technology in gait rehabilitation of patients after stroke
Nieboer, M. E., Jie, L.-J., Willemse, L., Peek, S. T. M., Braun, S., & Wouters, E. (2021) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2021.1936664 · Cited by 7
Wireless MEMS for wearable sensor networks
Milosevic, B., & Farella, E. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100449-4.00005-1 · Cited by 7
Self-citationTimmermann, C., Ursin, F., Predel, C., & Steger, F. (2021) · Sensors · doi:10.3390/s21248479 · Cited by 7
“The accuracy and precision is as good as in professional gait labs [15].”
BackgroundCorrelations of Gait Phase Kinematics and Cortical EEG: Modelling Human Gait with Data from Sensors
Nutakki, C. S., Bodda, S., & Diwakar, S. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.88465 · Cited by 7
Zhang, T., Dong, L., Hua, J., & Gao, S. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.668953 · Cited by 9
“5, mobile applications can help individuals with PD to achieve rehabilitation training in a home setting (48).”
BackgroundDžaja, D., Ćibarić, M., Šeketa, G., & Magjarević, R. (2022) · Automatika · doi:10.1080/00051144.2022.2121247 · Cited by 5
Tarniţă, D., Petcu, A., & Dumitru, N. (2020) · Romanian Journal of Morphology and Embryology · doi:10.47162/rjme.61.1.22 · Cited by 5
“Research papers studied healthy subjects [7, 9] or evaluated aspects related to the rehabilitation of joint movements after surgery, in prosthetic or orthotic patients [12–17], to evaluate the gait stability [18–25] or to identify movement kinematic differences in patient populations, such as patients with osteoarthri…”
BackgroundGait-Based User Identification for Smart Home: When Machine Learning Meets FBG Accelerometers
Alhussein, G., Chi, H. R., Alberto, N., Antunes, P. F. D. C., Hadjileontiadis, L. J., Radwan, A., & Domingues, M. F. (2024) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2024.3507872 · Cited by 4
“These may include trouble starting to walk, gait freezing (sudden pauses while walking), or a broad, unsteady stance [18].”
Reactive AI feedback Improves task performance over time
Berry, J. H. (2025) · Cognitive Systems Research · doi:10.1016/j.cogsys.2025.101361 · Cited by 4
Goubault, É., Duval, C., Martin, C., & Lebel, K. (2024) · Sensors · doi:10.3390/s24175486 · Cited by 4
“In recent years, algorithms using body-worn sensors have been developed to provide real-time feedback for rehabilitation [2,3] and pharmaceutical intervention [4,5].”
BackgroundDevelopment of an Auditory Cueing System to Assist Gait in Patients with Parkinson’s Disease
Guimar�ães, V., Castro, R., de Barros, A. C., Cevada, J., Bayés, À., Garcá, S., & Mestre, B. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-16480-9_10 · Cited by 3
Intelligent COVID-19 Forecasting, Diagnoses and Monitoring Systems: A SurveyPreprint
Anjum, N., Amna Asif, Kiran, M., Jabeen, F., Yang, Z., Huang, C., Noor, S., Imran, K., Ali, I., & Mohamed, E. M. (2021) · doi:10.36227/techrxiv.15172488 · Cited by 3
“The authors in [187] suggest that wearable sensors in combination with cameras can help in monitoring the progression of Parkinson’s Disease.”
BackgroundDeep Learning Empowered Human Gait Recognition with Improved Dense Capsule Networks
Jhapate, A. K., & Shrivastava, H. (2025) · SN Computer Science · doi:10.1007/s42979-025-04123-w · Cited by 2
“In healthcare, this technology plays a crucial role in diagnosing movement disorders and monitoring rehabilitation progress, offering objective metrics for healthcare professionals to track recovery [4–6].”
Which exercise intervention is most promising for Parkinson's balance? A network meta-analysis
Li, Y., Zhao, M., Luo, Z., & Tang, Y. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1879017 · Cited by 2
“The TUG primarily assesses motor function and the severity of freezing of gait (Casamassima et al., 2014).”
Context Aware Power Management Enhanced by Radio Wake Up in Body Area Networks
Casamassima, F., Magno, M., Farella, E., & Luca Benini, C. (2015) · IEEE International Conference on Computational Science and Engineering (CSE) and IEEE International Conference on Embedded and Ubiquitous Computing (EUC) · doi:10.1109/euc.2015.22 · Cited by 2
Self-citationCancela, J., Pastorino, M., & Arredondo, M. T. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3158-6.ch050 · Cited by 2
An optimized system for mobility evaluation in frailty phenotype assessment
Pierleoni, P., Belli, A., Pinti, F., Paoletti, M., Raggiunto, S., & Palma, L. (2022) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-022-03802-3 · Cited by 3
“These 3 points are determined with a findpeaks Matlab function (Casamassima et al. 2014).”
Pielka, M., Janik, P., Janik, M. A., & Wróbel, Z. (2022) · Sensors · doi:10.3390/s22249866 · Cited by 2
Jacob, S., Fernie, G. R., & Fekr, A. R. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3253519 · Cited by 2
Stergioulas, A., Dias, S. B., Alves, B., Hussein, G. A., Bostantjopoulou, S., Katsarou, Z., Dagklis, I. E., Grammalidis, N., & Dimitropoulos, K. (2024) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/3652037.3663945 · Cited by 3
“Research has demonstrated, for instance, that wearable sensors are capable of precisely measuring gait characteristics and identifying alterations in motor function linked to PD [17, 18].”
BackgroundShafi, S., Priya, R. P., Reddy, R. N., Bhuvanesh, R., Jennifer, M., & Adhil, M. (2024) · International Conference on Intelligent Technologies (CONIT) · doi:10.1109/conit61985.2024.10626258 · Cited by 3
“Authors in [15], have presented gait detection model based on Kalman filter and complimentary filter, and compared various performance parameters like accuracy and power efficiency along with cost of the model.”
MethodGrosjean, S., Giguère, L., Leach, J., & Mestre, T. (2025) · FACETS · doi:10.1139/facets-2024-0324 · Cited by 2
Is freezing of gait a balance disorder?
Mancini, M., Nutt, J. G., & Horak, F. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813874-8.00008-8 · Cited by 2
Ziegler, K. (2015) · Nervenheilkunde · doi:10.1055/s-0038-1627567 · Cited by 2
“Herkömmliche Cueing-Methoden wie Metronom oder Linien geben Zielparameter von außen vor, verbinden diese aber nicht mit der Leistung des Patienten (27).”
BackgroundIntelligent COVID-19 Forecasting, Diagnoses and Monitoring Systems: A SurveyPreprint
Anjum, N., Amna Asif, Kiran, M. S., Jabeen, F., Yang, Z., Huang, C., Noor, S., Imran, K., Ali, I., & Mohamed, E. M. (2021) · doi:10.36227/techrxiv.15172488.v1 · Cited by 3
Metadata
- Authors
- Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L.
- Affiliations
- University of Bologna (IT)
- KU Leuven (BE)
- Fondazione Bruno Kessler (IT)
- Corresponding author
- Farella, Elisabetta
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-03-28
- Volume
- 14
- Issue
- 4
- Pages
- 6229-6246
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4029669
- OpenAlex
- W2033453630
- Cited by
- 131
- References
- 45
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 12 · 2023: 6 · 2022: 14 · 2021: 9 · 2020: 13 · 2019: 9 · 2018: 10 · 2017: 16 · 2016: 15 · 2015: 14 · 2014: 1
- FWCI
- 39.74
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- Lirias (submittedVersion, other-oa)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- European Commission (2007–2013, FP7 2007-2013, 288516, FP7/2007)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- Parkinson's disease, gait training, wearable sensors, auditory feedback, auditory cueing, gait rehabilitation, wireless body sensor networks, real-time gait analysis, home-based rehabilitation
- MeSH terms
- Algorithms, Calibration, Computer Systems, Feedback, Gait, Humans, Male, Parkinson Disease, Telemetry, Thermodynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.