An IMU-to-Body Alignment Method Applied to Human Gait Analysis
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 2×
“, , l te t) s ft r I t i i I r r t i it coefficient (CCC, 95% IC) [28] between first-day measured joint angles (u ing IMU system) and referenc values (u ing the gold-standard universal goniometer) were sce ri analyzed: (a) the differences f joi t angl s m asures changing the postures (POS-1 and POS-2) of the se sors a…”
MethodMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 1×
“Also, it has been mentioned that the heading drift is mainly due to the accuracy of the IMU sensors and, on a lesser extent, to the complexity of the task [33].”
BackgroundAmbulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
A wearable system for gait training in subjects with Parkinson's disease
Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L. (2014) · Sensors · doi:10.3390/s140406229 · Cited by 131
Cited by
A Primer on Motion Capture with Deep Learning: Principles, Pitfalls, and Perspectives
Mathis, A., Schneider, S., Lauer, J., & Mathis, M. W. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.017 · Cited by 231
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Optimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Thigh Lateral mid-thigh 3 * Laudanski 2013 [19], Kong 2013 [16] Lateral near knee 2 Vargas-Valencia 2016 [26], Guo 2012 [28] Anterior near knee 2 Tadano 2013 [30], Lau 2008 [33]”
BackgroundPrediction of gait trajectories based on the Long Short Term Memory neural networks
Zaroug, A., Garofolini, A., Lai, D. T. H., Mudie, K., & Begg, R. (2021) · PLOS ONE · doi:10.1371/journal.pone.0255597 · Cited by 48
Metadata
- Authors
- Vargas-Valencia, L., Elias, A., Rocon, E., Bastos-Filho, T., & Frizera, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-12-10
- Volume
- 16
- Issue
- 12
- Pages
- 2090
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2562996226
- Cited by
- 116
- References
- 4
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An IMU-to-Body Alignment Method Applied to Human Gait Analysis. https://app.cochat.ai/papers/10.3390/s16122090
- The paper
- Vargas-Valencia, L., Elias, A., Rocon, E., Bastos-Filho, T., & Frizera, A. (2016). An IMU-to-Body Alignment Method Applied to Human Gait Analysis. Sensors. https://doi.org/10.3390/s16122090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.