The DOI matches its Crossref record.
Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review
Open accessAbstract
Humidity measurement is one of the most significant issues in various areas of applications such as instrumentation, automated systems, agriculture, climatology and GIS. Numerous sorts of humidity sensors fabricated and developed for industrial and laboratory applications are reviewed and presented in this article. The survey frequently concentrates on the RH sensors based upon their organic and inorganic functional materials, e.g., porous ceramics (semiconductors), polymers, ceramic/polymer and electrolytes, as well as conduction mechanism and fabrication technologies. A significant aim of this review is to provide a distinct categorization pursuant to state of the art humidity sensor types, principles of work, sensing substances, transduction mechanisms, and production technologies. Furthermore, performance characteristics of the different humidity sensors such as electrical and statistical data will be detailed and gives an added value to the report. By comparison of overall prospects of the sensors it was revealed that there are still drawbacks as to efficiency of sensing elements and conduction values. The flexibility offered by thick film and thin film processes either in the preparation of materials or in the choice of shape and size of the sensor structure provides advantages over other technologies. These ceramic sensors show faster response than other types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Lead‐Free Cs 2 BiAgBr 6 Double Perovskite‐Based Humidity Sensor with Superfast Recovery Time
Weng, Z., Qin, J., Umar, A. A., Wang, J., Zhang, X., Wang, H., Cui, X., Li, X., Zheng, L., & Zhan, Y. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201902234 · Cited by 236
Cho, M., Kim, S., Kim, I., Kim, E., Wang, Z., Kim, N., Kim, S., & Oh, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201907449 · Cited by 169
Wu, Z., Yang, J., Sun, X., Wu, Y., Wang, L., Meng, G., Kuang, D., Guo, X., Qu, W., Du, B., et al. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129772 · Cited by 142
Metadata
- Authors
- Farahani, H., Wagiran, R., & Hamidon, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-04-30
- Volume
- 14
- Issue
- 5
- Pages
- 7881-7939
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2001086979
- Cited by
- 1,286
- References
- 0
- FWCI
- 28.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review. https://app.cochat.ai/papers/10.3390/s140507881
- The paper
- Farahani, H., Wagiran, R., & Hamidon, M. (2014). Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review. Sensors. https://doi.org/10.3390/s140507881
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.