An Optical Fibre-Based Sensor for Respiratory Monitoring
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, a textile-based respiratory sensing system is presented. Highly flexible polymeric optical fibres (POFs) that react to applied pressure were integrated into a carrier fabric to form a wearable sensing system. After the evaluation of different optical fibres, different setups were compared. To demonstrate the feasibility of such a wearable sensor, the setup featuring the best performance was placed on the human torso, and thus it was possible to measure the respiratory rate. Furthermore, we show that such a wearable system enables to keep track of the way of breathing (diaphragmatic, upper costal and mixed) when the sensor is placed at different positions of the torso. A comparison of the results with the output of some commercial respiratory measurements devices confirmed the utility of such a monitoring device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Cited by
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“Beside these three primary methods, other technologies are being used to get respiratory waveform: accelerometers [30]; extracted from the ECG signal [31]; derived from pulse oximetry [32] polymer-based transducers sensors [33]; optical fibers [34]; etc.”
MethodWearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Polymer Optical Fiber Sensors in Healthcare Applications: A Comprehensive Review
Leal-Junior, A. G., Diaz, C. A. R., Avellar, L. M., Pontes, M. J., Marques, C., & Frizera, A. (2019) · Sensors · doi:10.3390/s19143156 · Cited by 211
“To that extent, a respiration monitoring using POFs integrated in a textile was proposed in reference [13], where the sensor was positioned in different regions of the chest in order to evaluate the type of respiration, e.”
BackgroundMethodTextile-Based Flexible Pressure Sensors: A Review
Zhang, J.-W., Zhang, Y., Li, Y.-Y., & Wang, P. (2022) · Polymer Reviews · doi:10.1080/15583724.2021.1901737 · Cited by 192
“Some POFs present high bending abilities, which means they can be integrated into textiles by weaving,([92]) sewing,([68]) and embroidery.([93]) Guignier et al.”
Background
Metadata
- Authors
- Krehel, M., Schmid, M., Rossi, R., Boesel, L., Bona, G.-L., & Scherer, L.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-07-21
- Volume
- 14
- Issue
- 7
- Pages
- 13088-13101
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1993749759
- Cited by
- 127
- References
- 1
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Optical Fibre-Based Sensor for Respiratory Monitoring. https://app.cochat.ai/papers/10.3390/s140713088
- The paper
- Krehel, M., Schmid, M., Rossi, R., Boesel, L., Bona, G.-L., & Scherer, L. (2014). An Optical Fibre-Based Sensor for Respiratory Monitoring. Sensors. https://doi.org/10.3390/s140713088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.