Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study proposes the use of flexible capacitive electrodes for reducing motion artifacts in a wearable electrocardiogram (ECG) device. The capacitive electrodes have conductive foam on their surface, a shield, an optimal input bias resistor, and guarding feedback. The electrodes are integrated in a chest belt, and the acquired signals are transmitted wirelessly for ambulatory heart rate monitoring. We experimentally validated the electrode performance with subjects standing and walking on a treadmill at speeds of up to 7 km/h. The results confirmed the highly accurate heart rate detection capacity of the developed system and its feasibility for daily-life ECG monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418 · cited 2×
“integrated electrodes into a cotton T-shirt [18].”
A new approach for non-intrusive monitoring of blood pressure on a toilet seat
Kim, J. S., Chee, Y. J., Park, J. W., Choi, J. W., & Park, K. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/2/010 · Cited by 64 · cited 1×
“Sensors integrated into home and office furniture and appliances such as chairs, toilet seats, baths, computer mice, and beds have been suggested to facilitate unconstrained long-term monitoring [2,4,13,14].”
BackgroundSelf-citation
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
“To avoid these drawbacks of wet electrodes, various types of dry electrodes have been introduced, as discussed in various publications [11–22].”
Virginia Anikwe, C., Friday Nweke, H., Chukwu Ikegwu, A., Adolphus Egwuonwu, C., Uchenna Onu, F., Rita Alo, U., & Wah Teh, Y. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.117362 · Cited by 233
Flexible Sensors—From Materials to Applications
Costa, J. C., Spina, F., Lugoda, P., Garcia-Garcia, L., Roggen, D., & Münzenrieder, N. (2019) · Technologies · doi:10.3390/technologies7020035 · Cited by 220
“Capacitively coupled electrodes with reduced effects of motion artifacts were fabricated using a conductive foam and are shown in Figure 13d [541].”
MethodNoncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L., Marinov, O., Chen, C.-H., Mondal, T., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 165
“used polymer materials, such as polydimethylsiloxane (PDMS) [20], [21] and ethylene propylene diene monomer [22], urethane [23], [24] as the substrate to improve the contact between”
BackgroundMethod
Metadata
- Authors
- Lee, J., Heo, J., Lee, W., Lim, Y., Kim, Y., & Park, K.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-08-12
- Volume
- 14
- Issue
- 8
- Pages
- 14732-14743
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2016698190
- Cited by
- 112
- References
- 2
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms. https://app.cochat.ai/papers/10.3390/s140814732
- The paper
- Lee, J., Heo, J., Lee, W., Lim, Y., Kim, Y., & Park, K. (2014). Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms. Sensors. https://doi.org/10.3390/s140814732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.