Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This research presents the ultrasonic proximity sensor approach to respiration measurement. The ultrasonic proximity sensor measures respiration signatures and rates in real-time and for long-term monitoring, which is necessary for mobility from the end-user perspective. The study used a 240 kHz ultrasonic sensor to measure the time of flight of a sound wave between the transmitted signal and received signal during respiration in the abdominal wall-motion. Respiration rates measured with the ultrasonic proximity sensor were then compared with those measured with a thermocouple sensor on ten male subjects. Data from the measurement of respiration rates at 100 cm is provided. We have used this data from the method comparison study to confirm agreement with the reference signal to determine that the current version of respiratory rate detection system using ultrasonic can successfully measure respiration rates. The proposed respiratory measurement method could be used to monitor an unconscious person without the need to apply electrodes or other sensors in the correct position and to wire the subject to the system. Monitoring respiration using ultrasonic sensor offers a promising possibility of noncontact measurement of respiration rates. In particular, this technology offers a potentially inexpensive means to extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the measurement, broadening the potential application areas of this technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“We assessed the agreement between respiration rates of all subjects measured by the nasal thermocouple sensor and the ultrasonic sensor using the Bland-Altman graphical approach [20]–[ 22 ].”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Breathing Detection: Towards a Miniaturized, Wearable, Battery-Operated Monitoring System
Corbishley, P., & Rodriguez-Villegas, E. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910679 · Cited by 221
A study on a non-contacting respiration signal monitoring system using Doppler ultrasound
Min, S. D., Yoon, D. J., Yoon, S. W., Yun, Y. H., & Lee, M. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0246-2 · Cited by 40 · cited 2×
“The work presented in this paper is a continuation of our previous study [13], using a higher frequency sensor yielding improved measurement resolution and less susceptibility to background noise.”
MethodResultSelf-citation
Cited by
Wang, H., Zhang, D., Ma, J., Wang, Y., Wang, Y., Wu, D., Gu, T., & Xie, B. (2016) · Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2971648.2971744 · Cited by 501
An Ultrasonic Contactless Sensor for Breathing Monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014) · Sensors · doi:10.3390/s140815371 · Cited by 102
“Electromagnetic waves can sense chest movement by Doppler effect [7 –10] or by analyzing the signal backscattered by breathing movements [11] and ultrasound waves telemeters permits detection of small body displacements during respiration [12,13].”
BackgroundNoninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974313 · Cited by 71
Allado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22
Nguyen, V. N., Duong, D. N., Chung, Y., & Lee, J.-W. (2018) · Sensors · doi:10.3390/s18113948 · Cited by 15
“The time interval between pulse signals is used for various sensing applications, for example, altitude sensing [2], depth sensing [3], respiration rate sensing [4], biomedical image sensing [5,6], and distance sensing for navigation [7].”
Metadata
- Authors
- Min, S. D., Kim, J. K., Shin, H. S., Yun, Y. H., Lee, C. K., & Lee, M.
- Venue
- IEEE Sensors Journal
- Published
- 2010-11
- Volume
- 10
- Issue
- 11
- Pages
- 1732-1739
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2139070213
- Cited by
- 168
- References
- 5
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor. https://app.cochat.ai/papers/10.1109/jsen.2010.2044239
- The paper
- Min, S. D., Kim, J. K., Shin, H. S., Yun, Y. H., Lee, C. K., & Lee, M. (2010). Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2010.2044239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.