Current Trends in Nanomaterial-Based Amperometric Biosensors
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The last decade has witnessed an intensive research effort in the field of electrochemical sensors, with a particular focus on the design of amperometric biosensors for diverse analytical applications. In this context, nanomaterial integration in the construction of amperometric biosensors may constitute one of the most exciting approaches. The attractive properties of nanomaterials have paved the way for the design of a wide variety of biosensors based on various electrochemical detection methods to enhance the analytical characteristics. However, most of these nanostructured materials are not explored in the design of amperometric biosensors. This review aims to provide insight into the diverse properties of nanomaterials that can be possibly explored in the construction of amperometric biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483 · cited 1×
“One such example is the construction of a glucose biosensor based on the reactivity of ferromagnetic nanoparticles towards hydrogen peroxide [47].”
BackgroundElectrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 1×
“The signals obtained are processed and transferred to a display or data storage device [1,2].”
Background
Cited by
Nanomaterials for biocatalyst immobilization – state of the art and future trends
Cipolatti, E. P., Valério, A., Henriques, R. O., Moritz, D. E., Ninow, J. L., Freire, D. M. G., Manoel, E. A., Fernandez-Lafuente, R., & de Oliveira, D. (2016) · RSC Advances · doi:10.1039/c6ra22047a · Cited by 326
Grattieri, M., & Minteer, S. D. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00818 · Cited by 312
Superparamagnetic nanoarchitectures for disease-specific biomarker detection
Masud, M. K., Na, J., Younus, M., Hossain, M. S. A., Bando, Y., Shiddiky, M. J. A., & Yamauchi, Y. (2019) · Chemical Society Reviews · doi:10.1039/c9cs00174c · Cited by 257
Nanomaterial-based electrochemical biosensors for food safety and quality assessment
Dridi, F., Marrakchi, M., Gargouri, M., Saulnier, J., Jaffrezic-Renault, N., & Lagarde, F. (2017) · Nanobiosensors · doi:10.1016/b978-0-12-804301-1.00005-9 · Cited by 40
Nano-in-Nano Approach for Enzyme Immobilization Based on Block Copolymers
Auriemma, F., De Rosa, C., Malafronte, A., Di Girolamo, R., Santillo, C., Gerelli, Y., Fragneto, G., Barker, R., Pavone, V., Maglio, O., et al. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b08959 · Cited by 29
Metadata
- Authors
- Hayat, A., Catanante, G., & Marty, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-12-08
- Volume
- 14
- Issue
- 12
- Pages
- 23439-23461
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2164977640
- Cited by
- 125
- References
- 2
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Trends in Nanomaterial-Based Amperometric Biosensors. https://app.cochat.ai/papers/10.3390/s141223439
- The paper
- Hayat, A., Catanante, G., & Marty, J. (2014). Current Trends in Nanomaterial-Based Amperometric Biosensors. Sensors. https://doi.org/10.3390/s141223439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.