Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called “organ-on-a-chip” technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 2×
“Some of the first studies have reported biomimetic microsystems reproducing the alveolar-capillary interface of the human lung as an alternative to animal and clinical studies, for drug screening and toxicology applications [75,183,184] (Figure 1B).”
BackgroundMethodDiagnosing the decline in pharmaceutical R&D efficiency
Scannell, J. W., Blanckley, A., Boldon, H., & Warrington, B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3681 · Cited by 1,981 · cited 3×
“, the past 60 years have seen huge advances in many of the scientific, technological and managerial factors that should tend to raise the efficiency of commercial drug R&D [199].”
BackgroundInfluentialFrom 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219 · cited 3×
“Kidney and kidney/liver microfluidic biochips [155–157] Microfluidics + optical fiber [132] μCCA [142,158] Microfluidic bioreactor [159] Microfluidic human kidney proximal tubule-on-a-chip device [160] MMD [121] Multiwell culture system [119] Endocrine System Cancer mechanisms Microfluidic co-culture model, chemokine…”
BackgroundMethodSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · cited 1×
“In turn, Xu and co-workers described experimental and theoretical approaches for soft microfluidics assemblies in sensors, circuits and radios for the skin [197].”
BackgroundOrgans-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185 · cited 1×
“This approach is believed to provide the basis for preclinical assays with greater predictive power [3].”
BackgroundPollen, A. A., Nowakowski, T. J., Shuga, J., Wang, X., Leyrat, A. A., Lui, J. H., Li, N., Szpankowski, L., Fowler, B., Chen, P., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.2967 · Cited by 920 · cited 2×
“Cell line characterization Microfluidics + electrophoresis [92] Microfluidics + quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) [93]”
BackgroundMethodMaschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Cited by
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Pamies, D. (2018) · ALTEX · doi:10.14573/altex.1710081 · Cited by 127
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Metadata
- Authors
- Perestrelo, A., Águas, A., Rainer, A., & Forte, G.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-12-10
- Volume
- 15
- Issue
- 12
- Pages
- 31142-31170
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2192571848
- Cited by
- 149
- References
- 31
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering. https://app.cochat.ai/papers/10.3390/s151229848
- The paper
- Perestrelo, A., Águas, A., Rainer, A., & Forte, G. (2015). Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering. Sensors. https://doi.org/10.3390/s151229848
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.