The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Complementary Split-Ring Resonator-Loaded Microfluidic Ethanol Chemical Sensor
Open accessAbstract
In this paper, a complementary split-ring resonator (CSRR)-loaded patch is proposed as a microfluidic ethanol chemical sensor. The primary objective of this chemical sensor is to detect ethanol’s concentration. First, two tightly coupled concentric CSRRs loaded on a patch are realized on a Rogers RT/Duroid 5870 substrate, and then a microfluidic channel engraved on polydimethylsiloxane (PDMS) is integrated for ethanol chemical sensor applications. The resonant frequency of the structure before loading the microfluidic channel is 4.72 GHz. After loading the microfluidic channel, the 550 MHz shift in the resonant frequency is ascribed to the dielectric perturbation phenomenon when the ethanol concentration is varied from 0% to 100%. In order to assess the sensitivity range of our proposed sensor, various concentrations of ethanol are tested and analyzed. Our proposed sensor exhibits repeatability and successfully detects 10% ethanol as verified by the measurement set-up. It has created headway to a miniaturized, non-contact, low-cost, reliable, reusable, and easily fabricated design using extremely small liquid volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Ammonia sensors and their applications—a review
Timmer, B., Olthuis, W., & Berg, A. V. D. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.11.054 · Cited by 1,714
The complex dielectric constant of pure and sea water from microwave satellite observations
Meissner, T., & Wentz, F. J. (2004) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2004.831888 · Cited by 803
Metamaterials with Negative Parameters
Marqués, R., Martı́n, F., & Sorolla, M. (2007) · Wiley eBooks · doi:10.1002/9780470191736 · Cited by 461
Semiconducting Metal Oxide Based Sensors for Selective Gas Pollutant Detection
Kanan, S. M., El-Kadri, O. M., Abu-Yousef, I. A., & Kanan, M. C. (2009) · Sensors · doi:10.3390/s91008158 · Cited by 447
ZnO nanoparticulate thin film: preparation, characterization and gas-sensing property
Cheng, X., Zhao, H., Huo, L., Gao, S., & Zhao, J. G. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.04.080 · Cited by 389
Novel hydrogen gas sensor based on single ZnO nanorod
Lupan, O. I., Chai, G., & Chow, L. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2008.06.021 · Cited by 353
Laterally grown ZnO nanowire ethanol gas sensors
Hsueh, T.-J., Hsu, C.-L., Chang, S.-J., & Chen, I.-C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.03.034 · Cited by 322
The role of gold catalyst on the sensing behavior of ZnO nanorods for CO and NO2 gases
Rai, P., Kim, Y.-S., Song, H.-M., Song, M.-K., & Yu, Y.-T. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.02.030 · Cited by 282
Displacement Sensor Based on Diamond-Shaped Tapered Split Ring Resonator
Horestani, A. K., Fumeaux, C., Al-Sarawi, S. F., & Abbott, D. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2231065 · Cited by 273
Synthesis and ethanol sensing characteristics of single crystalline SnO2 nanorods
Chen, Y. J., Xue, X. Y., Wang, Y. G., & Wang, T. H. (2005) · Applied Physics Letters · doi:10.1063/1.2140091 · Cited by 213
Yebo, N. A., Lommens, P., Hens, Z., & Baets, R. (2010) · Optics Express · doi:10.1364/oe.18.011859 · Cited by 172
Dielectric spectroscopy for bioanalysis: From 40 Hz to 26.5 GHz in a microfabricated wave guide
Facer, G. R., Notterman, D. A., & Sohn, L. L. (2001) · Applied Physics Letters · doi:10.1063/1.1347020 · Cited by 152
Microwaving Biological Cells: Intracellular Analysis with Microwave Dielectric Spectroscopy
Artis, F., Chen, T., Chretiennot, T., Fournié, J., Poupot, M., Dubuc, D., & Grenier, K. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2393997 · Cited by 114
Zhan, S., Li, D., Liang, S., Chen, X., & Xia, L. (2013) · Sensors · doi:10.3390/s130404378 · Cited by 105
Choi, S.-W., & Kim, S. S. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.100 · Cited by 92
Complex permittivity of water at 25 °C
Schwan, H. P., Sheppard, R. J., & Grant, E. H. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432416 · Cited by 82
Design and Sensing Properties of an Integrated Optical Gas Sensor Based on a Multilayer Structure
Airoudj, A., Debarnot, D., Bêche, B., & Poncin‐Epaillard, F. (2008) · Analytical Chemistry · doi:10.1021/ac801320g · Cited by 57
Ali, A. M., Hu, B., & Ramahi, O. M. (2015) · Sensors · doi:10.3390/s150511402 · Cited by 45
Optical control of terahertz nested split-ring resonators
Yuan, C., Zhao, X., Cao, X., Xu, S., Luan, N., & Yao, J. (2013) · Optical Engineering · doi:10.1117/1.oe.52.8.087111 · Cited by 7
Cited by
Su, D.-S., Tsai, D. P., Yen, T.-J., & Tanaka, T. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01225 · Cited by 39
Metadata
- Authors
- Salim, A., & Lim, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-10-28
- Volume
- 16
- Issue
- 11
- Pages
- 1802
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2542362329
- Cited by
- 253
- References
- 20
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.